Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0898125.U-1M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

125 A

Tab/Blade

38 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

KLKR03.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.5 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

0MIN05.0MXGLO

Littelfuse

Electric Fuse

Inline/Holder

12 V

5 A

Tab/Blade

-40 °C (-40 °F)

1 kA

30 ms

Bulk

0.43 in (10.92 mm)

0.15 in (3.81 mm)

Mini

0.345 in (8.76 mm)

125 °C (257 °F)

KLPC6000.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

6 kA

Tab/Blade

200 kA

10.752 in (273.1 mm)

L

600 V

10.752 x 4 in (273.1 x 101.6 mm)

4 in (101.6 mm)

CE; CSA; UL

Time Lag

0998080.UX-2M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

80 A

Tab/Blade

34.9 kJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

PSR030US0040Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

40 A

Tab/Blade

76 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

LA15QS350-4

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

350 A

Tab/Blade

32 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

1.13 in (28.7 mm)

1.13 x 1.161 in (28.7 x 29.5 mm)

1.161 in (29.5 mm)

UL

Very Fast

0895030.Z

Littelfuse

Electric Fuse

Inline/Holder

58 V

30 A

Tab/Blade

1.8 kJ

-40 °C (-40 °F)

1 kA

40 ms

Bulk

0.571 in (14.5 mm)

0.472 in (12 mm)

58 V

0.63 in (16 mm)

ISO; SAE

125 °C (257 °F)

LA100URD73LI1000

Littelfuse

Electric Fuse

Inline/Holder

1.1 KV

1 kA

Tab/Blade

370 J

100 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

2.933 x 2.933 x 2.854 in (74.5 x 74.5 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

PSR070UL0063Z

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

63 A

Tab/Blade

273 J

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.823 in (71.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

273004

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

4 A

Tab/Blade

1.38 J

-55 °C (-67 °F)

10 kA

2 s

Pre Arcing Time: Open within 2 s at 200% Rated Current

0.25 in (6.35 mm)

125 V

Micro

0.25 x 0.35 in (6.35 x 8.89 mm)

0.35 in (8.89 mm)

CSA; UL

85 °C (185 °F)

Very Fast

0498023.M

Littelfuse

Electric Fuse

23 A

Tab/Blade

-40 °C (-40 °F)

Tin

1 kA

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

JLLN500.X

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

500 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.594 in (40.5 mm)

300 V

3.063 in (77.8 mm)

CE; CSA; CUL; UL

Fast

NLS300

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

300 A

Tab/Blade

50 kA

Rated Breaking Capacity at 500 VDC; 50000

2.594 in (65.9 mm)

2.594 x 7.878 in (65.9 x 200.1 mm)

7.878 in (200.1 mm)

CSA; UL

LA30QS600-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

600 A

Tab/Blade

230 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.579 in (38.1 x 40.1 mm)

1.579 in (40.1 mm)

UL

Very Fast

LA30QS130-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

130 A

Tab/Blade

6.3 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.22 in (31 mm)

1.22 x 1.63 in (31 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

0TLS070.TXV

Littelfuse

Electric Fuse

Inline/Holder

170 V

70 A

Tab/Blade

Silver

100 kA

Bulk

0.563 in (14.3 mm)

e4

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

L70S100

Littelfuse

Electric Fuse

Inline/Holder

700 V

650 V

100 A

Tab/Blade

Silver

200 kA

Rated Breaking Capacity at 650 VDC: 20000 A

1.22 in (31 mm)

e4

1.22 x 2.874 in (31 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA50QS250-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

250 A

Tab/Blade

29 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

1.5 in (38.1 mm)

500 V

1.5 x 2.091 in (38.1 x 53.1 mm)

2.091 in (53.1 mm)

CSA; UL

Fast

NH00M160

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

160 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

LLNRK250

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

250 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.094 in (53.2 mm)

2.094 x 8.626 in (53.2 x 219.1 mm)

8.626 in (219.1 mm)

CSA; UL

Time Delay

KLH40

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

40 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 1.626 in (20.6 x 41.3 mm)

1.626 in (41.3 mm)

CSA; UL

Fast

0498030.MX1M5-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

4.2 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

125 °C (257 °F)

Time Delay

MIN3

Littelfuse

Electric Fuse

Inline/Holder

32 V

3 A

Tab/Blade

9.4 J

-40 °C (-40 °F)

1 kA

30 ms

Box

0.429 in (10.9 mm)

0.15 in (3.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

162.6185.4752

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

60 J

Tin

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

581050

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

50 A

Tab/Blade

2.5 kA

1.535 in (39 mm)

1.195 in (30.35 mm)

1.535 x 1.195 x 0.683 in (39 x 30.35 x 17.35 mm)

0.683 in (17.35 mm)

UL

JTD225ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

Indicator

2.126 x 3.374 in (54 x 85.7 mm)

3.374 in (85.7 mm)

CSA; UL

Time Delay

0CNN150.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

150 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

48 V

3.18 in (80.77 mm)

UL

Very Fast

262.700

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

700 mA

Tab/Blade

-55 °C (-67 °F)

Gold

10 kA

Rated Breaking Capacity at 125 VDC: 10000 A

0.235 in (5.97 mm)

e4

0.235 x 0.29 in (5.97 x 7.37 mm)

0.29 in (7.37 mm)

CSA; UL

125 °C (257 °F)

Very Fast

0581035

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

35 A

Tab/Blade

2.5 kA

1.535 in (39 mm)

1.195 in (30.35 mm)

48 V

1.535 x 0.683 in (39 x 17.35 mm)

0.683 in (17.35 mm)

UL

Fast

0298350ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

350 A

Tab/Blade

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

L60S125

Littelfuse

Electric Fuse

Inline/Holder

600 V

125 A

Tab/Blade

-55 °C (-67 °F)

200 kA

1.311 in (33.3 mm)

1.311 x 2.906 in (33.3 x 73.8 mm)

2.906 in (73.8 mm)

CSA; UL

125 °C (257 °F)

Very Fast

KLPC0450

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

157.5701.6401

Littelfuse

Electric Fuse

Inline/Holder

48 V

400 A

Tab/Blade

-40 °C (-40 °F)

2.4 kA

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

PSX1XLUB0125X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

125 A

Tab/Blade

7.091 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

175E-2CL-8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

175 A

Tab/Blade

80 kA

175E-2CL-8.25

7.94 in (201.68 mm)

7.94 x 16.131 in (201.68 x 409.72 mm)

16.131 in (409.72 mm)

Medium

0257030.LXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.51 kJ

-40 °C (-40 °F)

Tin/Copper

1 kA

4 d 4 h

1510

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

ATO

e2

32 V

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

Fast

L13S300

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

300 A

Tab/Blade

100 kA

L13S

Rated Breaking Capacity at 100 VDC: 20000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

Fast

0337003.PX2S

Littelfuse

Electric Fuse

Inline/Holder

32 V

3 A

Tab/Blade

9 J

-40 °C (-40 °F)

1 kA

20 ms

Bulk

0.567 in (14.4 mm)

0.165 in (4.2 mm)

32 V

Micro

0.417 in (10.6 mm)

125 °C (257 °F)

LA50QS1200-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

1.2 kA

Tab/Blade

930 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

3 in (76.2 mm)

500 V

3 x 3.22 in (76.2 x 81.8 mm)

3.22 in (81.8 mm)

CSA; UL

Fast

0498040.MXM6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

10 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

0998225.U-2M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

225 A

Tab/Blade

250 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.21 mm)

0.75 in (19.05 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

0891002H

Littelfuse

Electric Fuse

Inline/Holder

58 V

2 A

Tab/Blade

3 J

-40 °C (-40 °F)

Silver

1 kA

Bulk

0.429 in (10.9 mm)

0.15 in (3.8 mm)

e4

0.429 x 0.15 x 0.331 in (10.9 x 3.8 x 8.4 mm)

0.331 in (8.4 mm)

125 °C (257 °F)

PSX3XLUB0500X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

500 A

Tab/Blade

98.57 kJ

-55 °C (-67 °F)

250 kA

Bulk

5.067 in (128.7 mm)

2.894 in (73.5 mm)

Indicator

2.894 in (73.5 mm)

CUL; UL

125 °C (257 °F)

Fast

FLSR3.50ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; QPL; UL

Time Delay

PSR070UL0160Z

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

160 A

Tab/Blade

2.377 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.823 in (71.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR030US0315Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

315 A

Tab/Blade

7.131 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

TLN300

Littelfuse

Electric Fuse

Inline/Holder

170 V

300 A

Tab/Blade

Rated Breaking Capacity at 170 VDC: 100000 A

2.094 in (53.2 mm)

2.094 x 4.764 in (53.2 x 121 mm)

4.764 in (121 mm)

UL

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.