Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0CNL035.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

35 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

UL

Fast

164.6185.5106

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

110 J

Tin

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

164.6185.4502

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

35 J

Tin

1 kA

Bulk

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

L50S60

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

60 A

Tab/Blade

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 1.626 in (20.6 x 41.3 mm)

1.626 in (41.3 mm)

CSA; UL

Fast

033707.5LXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

47 J

-40 °C (-40 °F)

1 kA

20 ms

Bulk

0.567 in (14.4 mm)

0.165 in (4.2 mm)

32 V

Micro

0.417 in (10.6 mm)

125 °C (257 °F)

PSX1XLUB0100X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

100 A

Tab/Blade

3.54 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

TLS-V005

Littelfuse

Electric Fuse

Inline/Holder

170 V

5 A

Tab/Blade

Silver

Rated Breaking Capacity at 170 VDC: 100000

0.563 in (14.3 mm)

e4

0.563 x 1.26 in (14.3 x 32.004 mm)

1.26 in (32.004 mm)

UL

10-1003

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

-40 °C (-40 °F)

1 kA

80 ms

Pre Arcing Time: Open within 80 ms at 350% Rated Current

Blister

0.76 in (19.3 mm)

0.207 in (5.25 mm)

Indicator

0.76 x 0.207 x 0.48 in (19.3 x 5.25 x 12.2 mm)

0.48 in (12.2 mm)

125 °C (257 °F)

L13S250

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

250 A

Tab/Blade

100 kA

L13S

Rated Breaking Capacity at 100 VDC: 20000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

Fast

KLH600

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

600 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

2 in (50.8 mm)

2 x 2.22 in (50.8 x 56.4 mm)

2.22 in (56.4 mm)

CSA; UL

Fast

581700

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

700 A

Tab/Blade

2.5 kA

1.535 in (39 mm)

1.195 in (30.35 mm)

1.535 x 1.195 x 0.683 in (39 x 30.35 x 17.35 mm)

0.683 in (17.35 mm)

UL

Fast

0ATO007.5HXGLO

Littelfuse

Electric Fuse

Inline/Holder

14 V

7.5 A

Tab/Blade

-40 °C (-40 °F)

1 kA

80 ms

Bulk

0.758 in (19.25 mm)

0.207 in (5.25 mm)

0.484 in (12.3 mm)

105 °C (221 °F)

162.6185.5202

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

Tin

1 kA

Pre Arcing Time: Open within 0.020 s at 600% Rated Current

Bulk

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

CUL; UL

KLKD1/10-R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

100 mA

Tab/Blade

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

47 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.53 in (10.31 x 38.86 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Fast

TLS035LS

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

Silver

100 kA

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

KLPC4000.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

4 kA

Tab/Blade

200 kA

10.752 in (273.1 mm)

L

600 V

10.752 x 4 in (273.1 x 101.6 mm)

4 in (101.6 mm)

CE; CSA; UL

Time Lag

0287005.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

26 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

CNN400

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

400 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

2.43 in (61.72 mm)

UL

Very Fast

0298040.UX1M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

8.7 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

PSR070UL0250Z

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

250 A

Tab/Blade

8.629 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.823 in (71.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

0283140.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

140 A

Tab/Blade

-40 °C (-40 °F)

40 ms

1.874 in (47.6 mm)

0.593 in (15.05 mm)

32 V

0.898 x 0.638 x 0.846 in (22.8 x 16.2 x 21.5 mm)

0.846 in (21.5 mm)

125 °C (257 °F)

MIN2

Littelfuse

Electric Fuse

Inline/Holder

32 V

2 A

Tab/Blade

2.8 J

-40 °C (-40 °F)

1 kA

30 ms

Box

0.429 in (10.9 mm)

0.15 in (3.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0337005.PXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

17 J

-40 °C (-40 °F)

Silver

1 kA

20 ms

Bulk

0.567 in (14.4 mm)

0.165 in (4.2 mm)

e4

Micro

0.567 x 0.165 x 0.417 in (14.4 x 4.2 x 10.6 mm)

0.417 in (10.6 mm)

125 °C (257 °F)

CCK010

Littelfuse

Electric Fuse

Inline/Holder

125 V

10 A

Tab/Blade

10 kA

0.56 in (14.22 mm)

0.51 x 2.204 in (12.95 x 55.98 mm)

3.07 in (77.98 mm)

Time Delay

TLS-L080

Littelfuse

Electric Fuse

Inline/Holder

170 V

80 A

Tab/Blade

Silver

Rated Breaking Capacity at 170 VDC: 100000

0.563 in (14.3 mm)

e4

0.563 x 1.74 in (14.3 x 44.196 mm)

1.74 in (44.196 mm)

UL

70-2R-1BI-8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

70 A

Tab/Blade

190 A

Rated Breaking Capacity=190A-80000A

3 in (76.2 mm)

Indicator

3 x 18 in (76.2 x 457.2 mm)

18 in (457.2 mm)

Medium

SPNH0400.X3LDLMS

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

400 A

Tab/Blade

85 kJ

50 kA

Bulk

5.165 in (131.2 mm)

2.874 in (73 mm)

NH

2.874 in (73 mm)

UL

0998175.UX-1M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

175 A

Tab/Blade

79.3 kJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

2CM200

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

200 A

Tab/Blade

200 kA

2CM

Rated Breaking Capacity at 250 VDC: 80000 A

1.614 in (41 mm)

1.614 x 3.031 in (41 x 77 mm)

3.031 in (77 mm)

CSA

0JLS175.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

175 A

Tab/Blade

200 kA

Bulk

1.5 in (38.1 mm)

J

600 V

1.5 x 3 in (38.1 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; QPL; UL

Fast

0498150.SXT

Littelfuse

Electric Fuse

150 A

Tab/Blade

-40 °C (-40 °F)

1 kA

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

UL

125 °C (257 °F)

Time Lag

0891002.U

Littelfuse

Electric Fuse

Inline/Holder

58 V

2 A

Tab/Blade

3 J

-40 °C (-40 °F)

1 kA

30 ms

Bulk

0.429 in (10.9 mm)

0.15 in (3.8 mm)

58 V

Mini

0.299 in (7.6 mm)

ISO

125 °C (257 °F)

153.5631.5702

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

22 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

22000

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

FLSR4.50ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3.094 in (78.6 mm)

Indicator

3.094 x 13.374 in (78.6 x 339.7 mm)

13.374 in (339.7 mm)

CSA; QPL; UL

Time Delay

0898100.U-1M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

100 A

Tab/Blade

24 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

JLLS900.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

900 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.626 in (66.7 mm)

600 V

2.303 in (58.5 mm)

CE; CSA; UL

Fast

0298200.UX1M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

204 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

LVSP0005TXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

5 A

Tab/Blade

359 J

200 kA

0.41 in (10.41 mm)

1.53 in (38.86 mm)

UL

LA070URD31KI0700

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 A

Tab/Blade

95 J

200 kA

2.008 in (51 mm)

2.008 in (51 mm)

Indicator

2.008 x 2.008 x 1.874 in (51 x 51 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

NH00M40

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

40 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

153.7000.6202

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

126 kJ

-40 °C (-40 °F)

Tin

1.5 kA

100 ms

126000

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

CUL; ISO; UL

125 °C (257 °F)

KLSR350

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

350 A

Tab/Blade

200 kA

KLSR

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

11.626 in (295.3 mm)

CSA; UL

Fast

0498023.M-CN

Littelfuse

Electric Fuse

23 A

Tab/Blade

-40 °C (-40 °F)

Tin

1 kA

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

KLA500

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

500 A

Tab/Blade

100 kA

KLA

Rated Breaking Capacity at 100 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

CSA; UL

Fast

125E-1CL-5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

125 A

Tab/Blade

80 kA

4.75 in (120.65 mm)

4.75 x 15.13 in (120.65 x 384.3 mm)

15.13 in (384.3 mm)

Medium

07945894355

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

25 A

Tab/Blade

834.529 J

-55 °C (-67 °F)

100 kA

1.007 ms

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

2.085 ms

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

262.800

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

800 mA

Tab/Blade

-55 °C (-67 °F)

Gold

10 kA

Rated Breaking Capacity at 125 VDC: 10000 A

0.235 in (5.97 mm)

e4

0.235 x 0.29 in (5.97 x 7.37 mm)

0.29 in (7.37 mm)

CSA; UL

125 °C (257 °F)

Very Fast

LA070URD30LI0250

Littelfuse

Electric Fuse

Inline/Holder

700 V

250 A

Tab/Blade

5.8 J

200 kA

1.575 in (40 mm)

1.575 in (40 mm)

Indicator

1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.