Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 A |
Tab/Blade |
200 kA |
Bulk |
2.5 in (63.5 mm) |
2.5 x 3.752 in (63.5 x 95.3 mm) |
3.752 in (95.3 mm) |
CE; CSA; QPL; UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
1.6 A |
Tab/Blade |
-55 °C (-67 °F) |
10 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CE, UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
80 A |
Tab/Blade |
10 kA |
0.812 in (20.62 mm) |
0.812 x 1.625 in (20.62 x 41.28 mm) |
1.623 in (41.23 mm) |
Fast |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
125 V |
700 mA |
Tab/Blade |
71 mJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
0.071 |
0.25 in (6.35 mm) |
125 V |
Micro |
0.25 x 0.35 in (6.35 x 8.89 mm) |
0.35 in (8.89 mm) |
CSA; UL |
85 °C (185 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
125 A |
Tab/Blade |
15 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.008 in (51 mm) |
GPV |
1.5 KV |
NH |
2.008 in (51 mm) |
UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
225 A |
Tab/Blade |
250 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
5 A |
Tab/Blade |
25 J |
Matte Tin |
1 kA |
Rated Breaking Capacity at 125 VDC: 1000 A |
25 |
0.469 in (11.9 mm) |
0.15 in (3.8 mm) |
e3 |
125 V |
Mini |
0.469 x 0.15 x 0.339 in (11.9 x 3.8 x 8.6 mm) |
0.339 in (8.6 mm) |
UL |
||||||||||||
|
Littelfuse |
Electric Fuse |
30 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
32 V |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
35 A |
Tab/Blade |
8.4 kJ |
-40 °C (-40 °F) |
1 kA |
Bulk |
1.173 in (29.8 mm) |
0.358 in (9.1 mm) |
40 ms |
0.835 in (21.2 mm) |
85 °C (185 °F) |
Time Lag |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
225 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.311 in (33.3 mm) |
300 V |
2.752 in (69.9 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
200 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.559 in (65 mm) |
1.575 in (40 mm) |
Indicator |
2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm) |
2.835 in (72 mm) |
VDE |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
15 A |
Tab/Blade |
340 J |
-40 °C (-40 °F) |
Tin |
1 kA |
80 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm) |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
50 A |
Tab/Blade |
21.3 kJ |
-40 °C (-40 °F) |
1 kA |
10 ms |
Bulk |
1.654 in (42 mm) |
0.472 in (12 mm) |
1.654 x 0.472 x 0.016 in (42 x 12 x 0.4 mm) |
0.016 in (0.4 mm) |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
100 A |
Tab/Blade |
18.3 kJ |
-40 °C (-40 °F) |
2.5 kA |
70 ms |
0.63 in (16 mm) |
0.496 in (12.6 mm) |
0.323 in (8.2 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
90 A |
Tab/Blade |
100 kA |
Bulk |
1 in (25.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
31.1 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.063 in (27 mm) |
300 V |
2.437 in (61.9 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
60 A |
Tab/Blade |
Bulk |
||||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
550 A |
Tab/Blade |
57 J |
100 kA |
2.933 in (74.5 mm) |
2.933 in (74.5 mm) |
Indicator |
2.933 x 2.933 x 2.854 in (74.5 x 74.5 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
80 A |
Tab/Blade |
10 kA |
1.06 in (26.92 mm) |
1 x 3.454 in (25.4 x 87.73 mm) |
4.46 in (113.28 mm) |
Time Delay |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
80 A |
Tab/Blade |
24.6 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
73.2 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.327 in (8.3 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
450 V |
30 A |
Tab/Blade |
993 J |
-40 °C (-40 °F) |
10 kA |
50 ms |
0.406 in (10.3 mm) |
450 V |
1.531 in (38.9 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
480 V |
600 A |
Tab/Blade |
200 kA |
8.626 in (219.1 mm) |
L |
600 V |
8.626 x 3.752 in (219.1 x 95.3 mm) |
3.752 in (95.3 mm) |
CE; CSA; UL |
Time Lag |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
150 A |
Tab/Blade |
97.3 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
1.15 in (29.2 mm) |
0.75 in (19.05 mm) |
e3 |
32 V |
Mega |
0.381 in (9.69 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
225 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 600 VDC: 20000 A |
Bulk |
2.543 in (64.6 mm) |
2.5 x 11.626 in (63.5 x 295.3 mm) |
11.626 in (295.3 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
80 A |
Tab/Blade |
120 kA |
NH |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm) |
2.22 in (56.4 mm) |
DIN 43620; IEC; VDE |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
225 A |
Tab/Blade |
257 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
125 A |
Tab/Blade |
6.9 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A |
1.22 in (31 mm) |
1.22 x 2.874 in (31 x 73 mm) |
2.874 in (73 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
1.51 kJ |
-40 °C (-40 °F) |
Tin |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.74 in (18.8 mm) |
UL |
105 °C (221 °F) |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
250 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.559 in (65 mm) |
1.575 in (40 mm) |
Indicator |
2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm) |
2.835 in (72 mm) |
VDE |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
7 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
100 V |
90 A |
Tab/Blade |
100 kA |
L13S |
Rated Breaking Capacity at 100 VDC: 20000 A |
1 in (25.4 mm) |
1 x 1.157 in (25.4 x 29.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
60 A |
Tab/Blade |
2 kA |
Rated Breaking Capacity at 32 VDC: 2000 A |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
Slow |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
73.2 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
600 A |
200 ms |
Bulk |
1.26 in (32 mm) |
0.866 in (22 mm) |
48 V |
1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm) |
0.413 in (10.5 mm) |
CUL; UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
100 A |
Tab/Blade |
250 A |
Rated Breaking Capacity=250A-80000A |
3 in (76.2 mm) |
Indicator |
3 x 13 in (76.2 x 330.2 mm) |
13 in (330.2 mm) |
Medium |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
50 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.402 in (61 mm) |
1.575 in (40 mm) |
Indicator |
2.402 x 1.575 x 2.835 in (61 x 40 x 72 mm) |
2.835 in (72 mm) |
VDE |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
175 A |
Tab/Blade |
560 kJ |
-40 °C (-40 °F) |
1 kA |
10 ms |
Bulk |
1.654 in (42 mm) |
0.472 in (12 mm) |
1.654 x 0.472 x 0.016 in (42 x 12 x 0.4 mm) |
0.031 in (0.8 mm) |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
73.2 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.327 in (8.3 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
10 kA |
0.812 in (20.62 mm) |
1.623 in (41.23 mm) |
Fast |
||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
14 V |
3 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
80 ms |
Bulk |
0.758 in (19.25 mm) |
0.207 in (5.25 mm) |
0.484 in (12.3 mm) |
105 °C (221 °F) |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
80 A |
Tab/Blade |
Silver |
100 kA |
0.563 in (14.3 mm) |
e4 |
0.563 x 0.88 in (14.3 x 22.35 mm) |
0.88 in (22.35 mm) |
CE; UL |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
40 A |
Tab/Blade |
Blister |
||||||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
10 A |
Tab/Blade |
89 J |
-40 °C (-40 °F) |
Silver |
1 kA |
20 ms |
Bulk |
0.567 in (14.4 mm) |
0.165 in (4.2 mm) |
e4 |
Micro |
0.567 x 0.165 x 0.417 in (14.4 x 4.2 x 10.6 mm) |
0.417 in (10.6 mm) |
125 °C (257 °F) |
||||||||||||
|
Littelfuse |
Electric Fuse |
60 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
32 V |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
1 kJ |
-40 °C (-40 °F) |
1 kA |
20 ms |
Bulk |
0.358 in (9.1 mm) |
0.15 in (3.8 mm) |
32 V |
Micro |
0.311 in (7.9 mm) |
125 °C (257 °F) |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.