Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LMIN030.V

Littelfuse

Electric Fuse

Inline/Holder

58 V

30 A

Tab/Blade

1.1 kJ

-40 °C (-40 °F)

1 kA

30 ms

Box

0.429 in (10.9 mm)

0.15 in (3.8 mm)

Mini

0.299 in (7.6 mm)

125 °C (257 °F)

EV1K600.ZXBD

Littelfuse

Electric Fuse

Inline/Holder

1 KV

600 A

Tab/Blade

-40 °C (-40 °F)

30 kA

Bulk

2 in (50.8 mm)

2.844 in (72.24 mm)

125 °C (257 °F)

02400112P

Littelfuse

Electric Fuse

Inline/Holder

Tab/Blade

-40 °C (-40 °F)

Bulk

125 °C (257 °F)

MIC2015.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

190 J

-40 °C (-40 °F)

1 kA

20 ms

Bulk

0.358 in (9.1 mm)

0.15 in (3.8 mm)

Micro

0.311 in (7.9 mm)

125 °C (257 °F)

0MAX060.X

Littelfuse

Electric Fuse

Inline/Holder

32 V

60 A

Tab/Blade

15.3 kJ

-40 °C (-40 °F)

1 kA

40 ms

Box

1.15 in (29.2 mm)

0.346 in (8.8 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Slow

0MAX020.XP

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

1.1 kJ

-40 °C (-40 °F)

1 kA

40 ms

Bulk

1.15 in (29.2 mm)

0.346 in (8.8 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Slow

EV1K250.ZXBD

Littelfuse

Electric Fuse

Inline/Holder

1 KV

250 A

Tab/Blade

-40 °C (-40 °F)

30 kA

Bulk

2 in (50.8 mm)

2.844 in (72.24 mm)

125 °C (257 °F)

10EV040.ZXPY

Littelfuse

Electric Fuse

Inline/Holder

500 V

40 A

Tab/Blade

4.45 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

ATO30BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.5 kJ

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0ATO003.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

3 A

Tab/Blade

7.4 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV040.ZXPCB

Littelfuse

Electric Fuse

Inline/Holder

500 V

40 A

Tab/Blade

4.45 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

0ATO07.5ZXPRO

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

60 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0ATO001.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

1 A

Tab/Blade

400 mJ

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV010.ZXPCB

Littelfuse

Electric Fuse

Inline/Holder

500 V

10 A

Tab/Blade

316 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

0ATO004.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

4 A

Tab/Blade

14 J

-40 °C (-40 °F)

1 kA

100 ms

Box

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV020.ZXISO

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

ATO7.5BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

60 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV050.ZXISO

Littelfuse

Electric Fuse

Inline/Holder

500 V

50 A

Tab/Blade

7.803 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

0ATO015.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

340 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0ATO001.ZXPRO

Littelfuse

Electric Fuse

Inline/Holder

32 V

1 A

Tab/Blade

400 mJ

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

ATO2

Littelfuse

Electric Fuse

Inline/Holder

32 V

2 A

Tab/Blade

1.4 J

-40 °C (-40 °F)

1 kA

100 ms

Box

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV010.ZXPCBL

Littelfuse

Electric Fuse

Inline/Holder

500 V

10 A

Tab/Blade

316 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

MIC3005.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

17 J

-40 °C (-40 °F)

1 kA

20 ms

Bulk

0.567 in (14.4 mm)

0.165 in (4.2 mm)

Micro

0.417 in (10.6 mm)

125 °C (257 °F)

0ATO005.ZXPRO

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

26 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV050.ZXPY

Littelfuse

Electric Fuse

Inline/Holder

500 V

50 A

Tab/Blade

7.803 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

ATO10BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

115 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

ATO15BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

340 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV050.ZXPCB

Littelfuse

Electric Fuse

Inline/Holder

500 V

50 A

Tab/Blade

7.803 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

0ATO005.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

26 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

ATO40BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

3.3 kJ

-40 °C (-40 °F)

1 kA

150 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

ATO25BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

1 kJ

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV015.ZXISO

Littelfuse

Electric Fuse

Inline/Holder

500 V

15 A

Tab/Blade

803 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

MIC3015.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

189 J

-40 °C (-40 °F)

1 kA

20 ms

Box

0.567 in (14.4 mm)

0.165 in (4.2 mm)

Micro

0.417 in (10.6 mm)

125 °C (257 °F)

ATO40

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

3.3 kJ

-40 °C (-40 °F)

1 kA

150 ms

Box

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0ATO025.ZXPRO

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

1 kJ

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0ATO004.ZXPRO

Littelfuse

Electric Fuse

Inline/Holder

32 V

4 A

Tab/Blade

14 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV020.ZXBDP

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

0ATO07.5VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

60 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0ATO002.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

2 A

Tab/Blade

1.4 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV030.ZXPCB

Littelfuse

Electric Fuse

Inline/Holder

500 V

30 A

Tab/Blade

1.527 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

0ATO030.ZXPRO

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.5 kJ

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0ATO010.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

115 J

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

10EV040.ZXPCBL

Littelfuse

Electric Fuse

Inline/Holder

500 V

40 A

Tab/Blade

4.45 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV015.ZXPY

Littelfuse

Electric Fuse

Inline/Holder

500 V

15 A

Tab/Blade

803 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV015.ZXPCBL

Littelfuse

Electric Fuse

Inline/Holder

500 V

15 A

Tab/Blade

803 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV015.ZXPCB

Littelfuse

Electric Fuse

Inline/Holder

500 V

15 A

Tab/Blade

803 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV010.ZXBDP

Littelfuse

Electric Fuse

Inline/Holder

500 V

10 A

Tab/Blade

316 J

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

10EV030.ZXBDP

Littelfuse

Electric Fuse

Inline/Holder

500 V

30 A

Tab/Blade

1.527 kJ

-40 °C (-40 °F)

20 kA

50 ms

Bulk

0.406 in (10.3 mm)

1.531 in (38.9 mm)

125 °C (257 °F)

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.