Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
40 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Box |
0.81 in (20.57 mm) |
RK5 |
250 V |
0.811 x 3 in (20.6 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
40 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Box |
1.063 in (27 mm) |
1.063 x 5.5 in (27 x 139.7 mm) |
5.5 in (139.7 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
40 A |
End Cap |
200 kA |
0.811 in (20.6 mm) |
0.811 x 1.563 in (20.6 x 39.7 mm) |
1.563 in (39.7 mm) |
CE; CSA; UL |
Very Fast |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
40 A |
Tab/Blade |
60 J |
200 kA |
Rated Breaking Capacity at 250 VDC: 20000 A |
Box |
0.81 in (20.57 mm) |
0.81 x 1.59 in (20.57 x 40.39 mm) |
1.59 in (40.39 mm) |
CE; CSA; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
40 A |
End Cap |
84 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
Box |
0.563 in (14.3 mm) |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
IEC; UL |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
40 A |
End Cap |
50 kA |
Rated Breaking Capacity at 125 VDC: 50000 A |
Box |
0.81 in (20.57 mm) |
K5 |
250 V |
0.81 x 3 in (20.57 x 76.19 mm) |
3 in (76.19 mm) |
CE; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
40 A |
End Cap |
68 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
480 V |
300 V |
40 A |
End Cap |
100 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Box |
0.406 in (10.3 mm) |
G |
480 V |
0.406 x 2.25 in (10.3 x 57.15 mm) |
2.25 in (57.15 mm) |
CSA; UL |
Fast And Time Delay |
||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
40 A |
End Cap |
Box |
0.41 in (10.41 mm) |
0.41 x 1.5 in (10.41 x 38.1 mm) |
1.5 in (38.1 mm) |
Fast |
|||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
40 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
2.126 in (54 mm) |
0.984 in (25 mm) |
e3 |
Indicator |
2.13 x 1 x 1.125 in (54.1 x 25.4 x 28.58 mm) |
1.142 in (29 mm) |
CSA; UL |
80 °C (176 °F) |
Time Delay |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
40 A |
End Cap |
120 kA |
C14 |
0.551 in (14 mm) |
0.551 x 2.008 in (14 x 51 mm) |
2.008 in (51 mm) |
IEC |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.126 in (28.6 mm) |
J |
600 V |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
40 A |
End Cap |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.063 in (27 mm) |
J |
600 V |
1.063 x 2.374 in (27 x 60.3 mm) |
2.374 in (60.3 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
30 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Box |
0.394 in (10 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
40 A |
End Cap |
100 kA |
0.406 in (10.3 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
60 V |
100 mA |
Wraparound |
-40 °C (-40 °F) |
Tin Over Nickel |
100 A |
1 s |
Tape And Reel, 7 inch |
0.138 in (3.5 mm) |
0.071 in (1.8 mm) |
e3 |
60 V |
15 Ω |
1206 |
0.035 in (0.9 mm) |
TUV; UL |
85 °C (185 °F) |
Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
1.126 in (28.6 mm) |
J |
600 V |
Indicator |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
1 KV |
440 mA |
End Cap |
Nickel |
10 kA |
Box |
0.394 in (10 mm) |
1 KV |
0.394 x 1.374 in (10 x 34.9 mm) |
1.374 in (34.9 mm) |
UL |
22 °C (71.6 °F) |
Fast |
||||||||||||||
Eaton Corporation |
Electric Fuse |
||||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
15 A |
Tab/Blade |
-40 °C (-40 °F) |
Silver |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
Box |
0.43 in (10.92 mm) |
0.15 in (3.81 mm) |
e4 |
32 V |
0.43 x 0.15 x 0.347 in (10.92 x 3.81 x 8.81 mm) |
0.347 in (8.81 mm) |
UL |
100 °C (212 °F) |
Fast |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
150 V |
10 A |
End Cap |
200 kA |
Rated Breaking Capacity at 150 VDC: 20000 A |
Box |
0.394 in (10 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
200 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.63 in (41.4 mm) |
J |
600 V |
1.63 x 3 in (41.4 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
||||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
60 V |
50 mA |
Wraparound |
-40 °C (-40 °F) |
Tin with Nickel barrier |
100 A |
1.5 s |
Tape And Reel, 7 inch |
0.138 in (3.5 mm) |
0.071 in (1.8 mm) |
e3 |
60 V |
50 Ω |
1206 |
0.035 in (0.9 mm) |
TUV; UL |
85 °C (185 °F) |
Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
3 A |
End Cap |
100 kA |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA, UL |
Fast |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
10 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
32 V |
0.76 x 0.207 x 0.492 in (19.3 x 5.25 x 12.5 mm) |
0.483 in (12.28 mm) |
UL |
100 °C (212 °F) |
Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
200 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
1.63 in (41.4 mm) |
J |
600 V |
Indicator |
1.63 x 3 in (41.4 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
24 V |
200 mA |
Wraparound |
-40 °C (-40 °F) |
Tin Over Nickel |
100 A |
100 ms |
Tape And Reel, 7 inch |
0.138 in (3.5 mm) |
0.071 in (1.8 mm) |
e3 |
24 V |
2.6 Ω |
1206 |
0.027 in (0.68 mm) |
TUV; UL |
85 °C (185 °F) |
Fast |
||||||||||
Eaton Corporation |
Electric Fuse |
||||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
400 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
2.11 in (53.6 mm) |
J |
600 V |
2.11 x 1.508 in (53.6 x 38.3 mm) |
1.508 in (38.3 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
12 A |
End Cap |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
500 mA |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
1.25 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
11.498 J |
Nickel |
35 A |
Box |
0.25 in (6.35 mm) |
250 V |
0.252 x 1.248 in (6.4 x 31.7 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.4 KV |
1 KV |
10 A |
End Cap |
118 J |
50 kA |
Rated Breaking Capacity at 1000 VDC: 50000 A |
Box |
0.807 in (20.5 mm) |
0.807 x 5 in (20.5 x 127 mm) |
5 in (127 mm) |
CE; IEC |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.63 in (41.4 mm) |
J |
600 V |
1.63 x 3 in (41.4 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
30 V |
160 mA |
Wraparound |
-40 °C (-40 °F) |
Tin Over Nickel |
100 A |
300 ms |
Tape And Reel, 7 inch |
0.138 in (3.5 mm) |
0.071 in (1.8 mm) |
e3 |
30 V |
4.5 Ω |
1206 |
0.027 in (0.68 mm) |
TUV; UL |
85 °C (185 °F) |
Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.4 KV |
1 KV |
10 A |
End Cap |
118 J |
50 kA |
Rated Breaking Capacity at 1000 VDC: 50000 A |
Box |
0.807 in (20.5 mm) |
Indicator |
0.807 x 5 in (20.5 x 127 mm) |
5 in (127 mm) |
CE; IEC |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
1 KV |
440 mA |
End Cap |
Nickel |
10 kA |
Rated Breaking Capacity at 1000 VDC: 10000 A |
Box |
0.394 in (10 mm) |
1 KV |
0.394 x 1.374 in (10 x 34.9 mm) |
1.374 in (34.9 mm) |
UL |
Fast |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
40 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
32 V |
0.76 x 0.207 x 0.492 in (19.3 x 5.25 x 12.5 mm) |
0.483 in (12.28 mm) |
UL |
100 °C (212 °F) |
Fast |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
150 V |
3 A |
End Cap |
200 kA |
Rated Breaking Capacity at 150 VDC: 20000 A |
Box |
0.394 in (10 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
150 V |
15 A |
End Cap |
200 kA |
Rated Breaking Capacity at 150 VDC: 20000 A |
Box |
0.394 in (10 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
Silver |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.126 in (28.6 mm) |
e4 |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
15 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
125 V |
10 A |
End Cap |
Silver |
10 kA |
0.406 in (10.31 mm) |
e4 |
125 V |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA, UL |
Time Lag |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
10 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
15 A |
End Cap |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
20 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Box |
0.394 in (10 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.