Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
10 A |
End Cap |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
0.811 in (20.6 mm) |
J |
600 V |
Indicator |
0.811 x 2.252 in (20.6 x 57.2 mm) |
2.252 in (57.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
90 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
1.126 in (28.6 mm) |
J |
600 V |
Indicator |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
150 V |
3.5 A |
End Cap |
200 kA |
Rated Breaking Capacity at 150 VDC: 20000 A |
Box |
0.394 in (10 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
20 A |
Tab/Blade |
490 J |
120 kA |
Box |
1.929 in (49 mm) |
0.827 in (21 mm) |
NH000 |
Indicator |
1.614 in (41 mm) |
CE; DIN; IEC; VDE |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
12 A |
End Cap |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
0.811 in (20.6 mm) |
J |
600 V |
0.811 x 2.252 in (20.6 x 57.2 mm) |
2.252 in (57.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
45 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Box |
0.81 in (20.57 mm) |
0.81 x 1.56 in (20.57 x 39.62 mm) |
1.56 in (39.62 mm) |
CSA; UL |
Time Lag |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
24 V |
30 A |
Wraparound |
43 J |
-55 °C (-67 °F) |
300 A |
5 s |
Pre Arcing Time: Open within 5 s at 350% Rated Current |
43 |
Tape And Reel, 7 inch |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
24 V |
1206 |
0.126 x 0.063 x 0.035 in (3.2 x 1.6 x 0.89 mm) |
0.035 in (0.89 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
|||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
5 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
6.25 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Box |
0.56 in (14.22 mm) |
RK5 |
250 V |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
20 A |
End Cap |
2.44 kJ |
-55 °C (-67 °F) |
Nickel |
1 kA |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
1.438 |
Box |
0.25 in (6.35 mm) |
32 V |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
3 A |
End Cap |
45.9 J |
-55 °C (-67 °F) |
Nickel |
100 A |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
0.0167 |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
2.8 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Surface Mount |
125 V |
80 V |
50 A |
Tab/Blade |
2.5 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Very Fast |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
1 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Through Hole Mount |
250 V |
100 mA |
Pin Wire |
15.155 mJ |
-40 °C (-40 °F) |
35 A |
Bag |
0.335 in (8.5 mm) |
20 ms |
0.335 x 0.319 in (8.5 x 8.1 mm) |
0.319 in (8.1 mm) |
CCC; CUL; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
90 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
2.992 in (76 mm) |
0.984 in (25 mm) |
e3 |
Indicator |
3.01 x 1 x 1.26 in (76.45 x 25.4 x 32 mm) |
1.26 in (32 mm) |
CSA; UL |
80 °C (176 °F) |
Time Delay |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
5 A |
End Cap |
32.83 J |
Nickel |
200 A |
2 m |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
Box |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
20 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
Box |
0.43 in (10.92 mm) |
0.15 in (3.81 mm) |
32 V |
0.43 x 0.15 x 0.347 in (10.92 x 3.81 x 8.81 mm) |
0.347 in (8.81 mm) |
UL |
100 °C (212 °F) |
Fast |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
7 A |
End Cap |
Nickel |
10 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
500 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
|||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
90 A |
Tab/Blade |
Silver |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.126 in (28.6 mm) |
e4 |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Through Hole Mount |
250 V |
100 mA |
Pin Wire |
15.155 mJ |
-40 °C (-40 °F) |
35 A |
Ammo Pack |
0.335 in (8.5 mm) |
20 ms |
0.335 x 0.319 in (8.5 x 8.1 mm) |
0.319 in (8.1 mm) |
CCC; CUL; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
486 J |
-55 °C (-67 °F) |
Nickel |
200 A |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
0.492 |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
5 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
Box |
0.43 in (10.92 mm) |
0.15 in (3.81 mm) |
32 V |
0.43 x 0.15 x 0.347 in (10.92 x 3.81 x 8.81 mm) |
0.347 in (8.81 mm) |
UL |
100 °C (212 °F) |
Fast |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
1.5 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Box |
0.394 in (10 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
2.25 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Box |
0.394 in (10 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
2 A |
End Cap |
2.167 J |
Nickel |
100 A |
2 m |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
Box |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
|||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
15 A |
End Cap |
200.2 J |
750 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; MIL-F-15160/03; UL |
Fast |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
100 A |
Box |
0.406 in (10.3 mm) |
250 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
30 A |
End Cap |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
480 V |
300 V |
60 A |
End Cap |
100 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Box |
0.406 in (10.3 mm) |
G |
480 V |
0.406 x 2.25 in (10.3 x 57.15 mm) |
2.25 in (57.15 mm) |
CSA; UL |
Fast And Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
60 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
2.126 in (54 mm) |
0.984 in (25 mm) |
e3 |
Indicator |
2.13 x 1 x 1.125 in (54.1 x 25.4 x 28.58 mm) |
1.142 in (29 mm) |
CSA; UL |
80 °C (176 °F) |
Time Delay |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
2 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
5 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
315 A |
Tab/Blade |
10 kJ |
200 kA |
Box |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
3 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
300 A |
Tab/Blade |
9.8 kJ |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
1.5 in (38.1 mm) |
1.5 x 2.09 in (38.1 x 53.09 mm) |
2.09 in (53.09 mm) |
CE; CSA; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
3 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
5 A |
End Cap |
380.49 J |
Nickel |
200 A |
2 m |
Rated Breaking Capacity at 125 VDC: 10000 A |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA, UL |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
80 V |
300 A |
End Cap |
2.7 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
25 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
Box |
0.43 in (10.92 mm) |
0.15 in (3.81 mm) |
e3 |
32 V |
0.43 x 0.15 x 0.347 in (10.92 x 3.81 x 8.81 mm) |
0.347 in (8.81 mm) |
UL |
100 °C (212 °F) |
Fast |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
Box |
0.43 in (10.92 mm) |
0.15 in (3.81 mm) |
e3 |
32 V |
0.43 x 0.15 x 0.347 in (10.92 x 3.81 x 8.81 mm) |
0.347 in (8.81 mm) |
UL |
100 °C (212 °F) |
Fast |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
17.5 A |
End Cap |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
35 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Box |
0.81 in (20.57 mm) |
RK5 |
250 V |
0.811 x 3 in (20.6 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
35 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Box |
0.81 in (20.57 mm) |
RK5 |
250 V |
0.811 x 3 in (20.6 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
63 A |
End Cap |
280 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
10 A |
End Cap |
100 kA |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
32 V |
50 V |
500 mA |
Wraparound |
1.93 mJ |
-55 °C (-67 °F) |
Tin with Nickel barrier |
50 A |
1 m |
Rated Breaking Capacity at 50 VDC: 35 A |
0.0019 |
Tape And Reel, Paper, 7 inch |
0.063 in (1.6 mm) |
0.032 in (0.81 mm) |
e3 |
32 V |
0603 |
0.063 x 0.032 x 0.019 in (1.6 x 0.81 x 0.48 mm) |
0.019 in (0.48 mm) |
AEC-Q200; CSA; UL |
125 °C (257 °F) |
Fast |
||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
450 V |
175 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 450 VDC: 100000 A |
1.63 in (41.4 mm) |
1.63 x 3 in (41.4 x 76.2 mm) |
3 in (76.2 mm) |
CSA; UL |
Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.