Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
100 A |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.218 x 0.831 in (5.54 x 21.1 mm) |
0.787 in (20 mm) |
UL; VDE |
Fast |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
|||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
3.5 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
200 A |
Tab/Blade |
10 kA |
Rated Breaking Capacity at 125 VDC: 10000 A |
Box |
1.56 in (39.62 mm) |
H |
250 V |
1.56 x 7.13 in (39.62 x 181.1 mm) |
7.13 in (181.1 mm) |
CE; CSA; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Through Hole Mount |
250 V |
1 A |
Pin Wire |
7.5 J |
-40 °C (-40 °F) |
35 A |
Bag |
0.335 in (8.5 mm) |
20 ms |
0.335 x 0.319 in (8.5 x 8.1 mm) |
0.319 in (8.1 mm) |
CCC; CUL; KC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
125 V |
4 A |
End Cap |
19 J |
Nickel |
10 kA |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
Box |
0.205 in (5.2 mm) |
125 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CSA; PSE; UL |
Fast |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
18 kJ |
200 kA |
Box |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
240 V |
150 V |
80 A |
Tab/Blade |
300 J |
200 kA |
Rated Breaking Capacity at 150 VDC: 200000 A |
Box |
0.697 in (17.7 mm) |
0.697 x 1.031 in (17.7 x 26.2 mm) |
1.031 in (26.2 mm) |
CE; IEC; UL |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Surface Mount |
125 V |
80 V |
40 A |
Tab/Blade |
2.5 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Very Fast |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Through Hole Mount |
250 V |
500 mA |
Pin Wire |
2.28 J |
Tin |
35 A |
Pre Arcing Time: Open within 3 s at 200% Rated Current |
Box |
0.217 in (5.5 mm) |
e3 |
250 V |
0.197 x 0.591 in (5 x 15 mm) |
0.217 x 0.598 in (5.5 x 15.2 mm) |
0.598 in (15.2 mm) |
CSA; UL |
Time Delay |
||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
208 V |
125 V |
5 A |
Tab/Blade |
Silver |
4.2 kA |
Rated Breaking Capacity at 125 VDC: 6000 A |
0.484 in (12.3 mm) |
e4 |
0.484 x 1.331 in (12.3 x 33.8 mm) |
1.331 in (33.8 mm) |
Fast |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
|||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
250 V |
60 V |
50 A |
Wraparound |
600 J |
-55 °C (-67 °F) |
Silver with Nickel barrier |
300 A |
Interrupting Current Max(DC): 600 A; Pre Arcing Time: Open within 60 s at 200% Rated Current |
Tape And Reel, 13 inch |
0.488 in (12.4 mm) |
0.177 in (4.5 mm) |
e4 |
0.488 x 0.177 x 0.177 in (12.4 x 4.5 x 4.5 mm) |
0.177 in (4.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
30 A |
Tab/Blade |
-40 °C (-40 °F) |
50 kA |
1.89 in (48 mm) |
0.748 in (19 mm) |
240 s |
0.984 in (25 mm) |
CE; CUL; UL |
90 °C (194 °F) |
Fast |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
800 V |
350 A |
Tab/Blade |
17 kJ |
50 kA |
2.126 in (54 mm) |
1.429 in (36.3 mm) |
0.945 in (24 mm) |
UL |
||||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
16 kJ |
50 kA |
2.835 in (72 mm) |
1.429 in (36.3 mm) |
0.945 in (24 mm) |
IEC; UL |
||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
700 A |
Tab/Blade |
44.5 kJ |
200 kA |
Rated Breaking Capacity at 700 VDC: 200000 A |
Box |
2.992 in (76 mm) |
2.008 in (51 mm) |
Indicator |
2.992 x 2.008 x 2.992 in (76 x 51 x 76 mm) |
2.992 in (76 mm) |
CE; IEC; UL |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
6.45 J |
Nickel |
35 A |
6.45 |
Bag |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; IMQ; PSE; SEMKO; UL; VDE |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
300 V |
160 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 160 VDC: 20000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 0.843 in (22.2 x 21.4 mm) |
0.843 in (21.4 mm) |
CE; CSA; UL |
Very Fast |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
200 A |
Tab/Blade |
4.2 kJ |
200 kA |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
Indicator |
2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm) |
1.575 in (40 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
160 A |
Tab/Blade |
1.9 kJ |
200 kA |
Box |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
350 A |
Tab/Blade |
21.5 kJ |
150 kA |
3.15 in (80 mm) |
2.008 in (51 mm) |
Indicator |
3.15 x 2.008 x 2.008 in (80 x 51 x 51 mm) |
2.008 in (51 mm) |
CE; DIN 43653; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
6.45 J |
Nickel |
35 A |
6.45 |
Bulk |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; IMQ; PSE; SEMKO; UL; VDE |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
Nickel |
100 A |
Bag |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CSA; CUL; SEMKO; UL; VDE |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
25 A |
End Cap |
120 kA |
C10 |
0.394 in (10 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
IEC |
||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
5.5 KV |
5.5 KV |
500 A |
Tab/Blade |
Silver |
63 kA |
ECL055 |
e4 |
Indicator |
||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
80 A |
Tab/Blade |
-40 °C (-40 °F) |
200 kA |
Pre Arcing Time: Clear within 8 m at 200% Rated Current; Rated Breaking Capacity at 600 VDC: 50000 A |
Box |
2.992 in (76 mm) |
0.984 in (25 mm) |
1.26 in (32 mm) |
CE; CSA; UL |
80 °C (176 °F) |
Fast |
||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
150 V |
150 V |
350 A |
Tab/Blade |
15.7 kJ |
100 kA |
Rated Breaking Capacity at 150 VDC: 20000 A |
Box |
1 in (25.4 mm) |
1 x 1.156 in (25.4 x 29.36 mm) |
1.156 in (29.36 mm) |
CE; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Through Hole Mount |
250 V |
2.5 A |
Pin Wire |
40.3 J |
-40 °C (-40 °F) |
Tin |
35 A |
40.3 |
Bag |
0.335 in (8.5 mm) |
0.169 in (4.3 mm) |
e3 |
250 V |
0.335 x 0.169 x 0.329 in (8.5 x 4.3 x 8.35 mm) |
0.329 in (8.35 mm) |
CQC; EK; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Delay |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
24 V |
15 A |
Wraparound |
25.5 J |
-55 °C (-67 °F) |
150 A |
5 s |
Pre Arcing Time: Open within 5 s at 350% Rated Current |
25 |
Tape And Reel, 7 inch |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
24 V |
1206 |
0.126 x 0.063 x 0.035 in (3.2 x 1.6 x 0.89 mm) |
0.035 in (0.89 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
|||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
32 V |
63 V |
1.5 A |
Wraparound |
93 mJ |
-55 °C (-67 °F) |
50 A |
5 s |
Pre Arcing Time: Open within 5 s at 250% Rated Current |
0.093 |
Tape And Reel, 7 inch |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
63 V |
1206 |
0.126 x 0.063 x 0.035 in (3.2 x 1.6 x 0.89 mm) |
0.035 in (0.89 mm) |
AEC-Q200; CSA; UL |
125 °C (257 °F) |
Fast |
||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
250 V |
125 V |
1 A |
End Cap |
9.91 J |
50 A |
4 h |
Rated Breaking Capacity at 125 VDC: 50 A |
9.91 |
Tape And Reel |
0.405 in (10.29 mm) |
0.109 in (2.77 mm) |
250 V |
0.405 x 0.109 x 0.109 in (10.29 x 2.77 x 2.77 mm) |
0.109 in (2.77 mm) |
CSA; UL |
Time Delay |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
250 A |
Tab/Blade |
4.2 kJ |
200 kA |
Box |
1.772 in (45 mm) |
1.772 in (45 mm) |
Indicator |
1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
15 kJ |
200 kA |
Box |
1.772 in (45 mm) |
1.772 in (45 mm) |
Indicator |
1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
10 kJ |
150 kA |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; DIN 43653; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 A |
Tab/Blade |
60.5 kJ |
200 kA |
Box |
1.969 in (50 mm) |
2.402 in (61 mm) |
Indicator |
1.969 x 2.402 x 2.402 in (50 x 61 x 61 mm) |
2.402 in (61 mm) |
CE; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
1.1 kA |
End Cap |
575 kJ |
100 kA |
3.189 in (81 mm) |
2.992 in (76 mm) |
Indicator |
3.189 x 2.992 x 2.992 in (81 x 76 x 76 mm) |
2.992 in (76 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
2 kA |
Tab/Blade |
600 kJ |
200 kA |
Box |
4.134 in (105 mm) |
2.087 in (53 mm) |
Indicator |
4.134 x 2.087 x 4.134 in (105 x 53 x 105 mm) |
4.134 in (105 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
32 A |
Tab/Blade |
1.8 kJ |
120 kA |
Box |
1.929 in (49 mm) |
0.827 in (21 mm) |
NH000 |
Indicator |
1.614 in (41 mm) |
CE; DIN; IEC; VDE |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
3.15 A |
End Cap |
13 J |
Nickel |
35 A |
Bag |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE |
Fast |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
315 mA |
End Cap |
580 mJ |
Nickel |
35 A |
Bag |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE |
Fast |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
20 A |
End Cap |
120 kA |
C10 |
0.394 in (10 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
IEC |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
450 V |
30 A |
End Cap |
200 kA |
Rated Breaking Capacity at 450 VDC: 100000 A |
0.81 in (20.57 mm) |
0.81 x 2.25 in (20.57 x 57.15 mm) |
2.25 in (57.15 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
480 mJ |
Nickel |
1.5 kA |
Tape And Reel |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; SEMKO; UL |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
32 V |
63 V |
250 mA |
Wraparound |
380 μJ |
-55 °C (-67 °F) |
50 A |
5 s |
Pre Arcing Time: Open within 5 s at 250% Rated Current |
0.0003 |
Tape And Reel, 7 inch |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
63 V |
1206 |
0.126 x 0.063 x 0.035 in (3.2 x 1.6 x 0.89 mm) |
0.035 in (0.89 mm) |
AEC-Q200; CSA; UL |
125 °C (257 °F) |
Fast |
||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
250 A |
Tab/Blade |
7.9 kJ |
200 kA |
1.378 in (35 mm) |
0.807 in (20.5 mm) |
1.378 x 0.807 x 1.957 in (35 x 20.5 x 49.7 mm) |
1.957 in (49.7 mm) |
CE; CSA; IEC; UL |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
200 A |
Tab/Blade |
3.4 kJ |
200 kA |
Box |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
160 A |
Tab/Blade |
4.35 kJ |
300 kA |
1.929 in (49 mm) |
1.181 in (30 mm) |
Indicator |
1.929 x 1.181 x 2.362 in (49 x 30 x 60 mm) |
2.362 in (60 mm) |
CE; DIN 43620; IEC; UL |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.