Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
6.3 A |
End Cap |
62.465 J |
-55 °C (-67 °F) |
Nickel |
63 A |
10 ms |
62.465 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
63 mA |
End Cap |
560 μJ |
-55 °C (-67 °F) |
Tin |
35 A |
3 ms |
Pre Arcing Time: Open within 0.01 s at 400% Rated Current |
Bulk |
0.205 in (5.2 mm) |
e3 |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
630 mA |
End Cap |
410 mJ |
-55 °C (-67 °F) |
35 A |
10 ms |
Pre Arcing Time: Open within 10 ms at 400% Rated Current |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; CUL; KC; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
40 A |
Tab/Blade |
3.3 kJ |
-40 °C (-40 °F) |
Tin |
1 kA |
80 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm) |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
5 A |
Pin Wire |
54.8 J |
-60 °C (-76 °F) |
Tin |
50 A |
2 ms |
Pre Arcing Time: Blow within 0.002 s at 800% Rated Current |
54.8 |
Tape And Reel |
0.135 in (3.43 mm) |
e3 |
125 V |
Pico |
0.135 x 0.28 in (3.43 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Time Delay |
|||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
10 A |
Wraparound |
10.385 J |
-55 °C (-67 °F) |
Matte Tin Over Nickel |
150 A |
4 h |
10.385 |
Tape And Reel |
0.126 in (3.2 mm) |
0.064 in (1.62 mm) |
e3 |
32 V |
4.27 mΩ |
1206 |
0.126 x 0.064 x 0.032 in (3.2 x 1.62 x 0.82 mm) |
0.032 in (0.82 mm) |
CSA; UL |
150 °C (302 °F) |
Fast |
|||||||
Eaton Corporation |
Electric Fuse |
||||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
250 V |
3 A |
Tab/Blade |
200 kA |
0.543 in (13.8 mm) |
0.543 x 1.398 in (13.8 x 35.5 mm) |
1.398 in (35.5 mm) |
||||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
400 V |
50 A |
End Cap |
7.8 kJ |
50 kA |
Bulk |
0.591 in (15 mm) |
D02 |
0.591 x 1.417 in (15 x 36 mm) |
1.417 in (36 mm) |
DIN 49515; IEC60269 |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.142 x 2.638 in (29 x 67 mm) |
4.606 in (117 mm) |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.787 in (45.4 mm) |
Indicator |
9.626 in (244.5 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.787 in (45.4 mm) |
Indicator |
9.626 in (244.5 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 mA |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
400 mA |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
1.4 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Box |
0.394 in (10 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
100 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
15 A |
End Cap |
365 J |
-55 °C (-67 °F) |
20 kA |
4 m |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
20 A |
End Cap |
804.3 J |
-55 °C (-67 °F) |
20 kA |
4 m |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
25 A |
End Cap |
1.202 kJ |
-55 °C (-67 °F) |
20 kA |
4 m |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
30 A |
End Cap |
2.229 kJ |
-55 °C (-67 °F) |
20 kA |
4 m |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
15 A |
Tab/Blade |
365 J |
-55 °C (-67 °F) |
20 kA |
4 m |
Tray |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
25 A |
Tab/Blade |
1.202 kJ |
-55 °C (-67 °F) |
20 kA |
4 m |
Tray |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Mersen S A |
Electric Fuse |
Panel Mount |
1.25 KV |
250 A |
Threaded |
9.58 kJ |
150 kA |
Bulk |
2.913 in (74 mm) |
1.567 in (39.8 mm) |
AR |
70 |
Indicator |
1.831 in (46.5 mm) |
CCC; CE; CSA; CUL; EAC; IEC; UL; VDE |
Ultra Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
30 A |
Tab/Blade |
1.15 kJ |
-40 °C (-40 °F) |
20 kA |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
30 A |
Tab/Blade |
1.15 kJ |
-40 °C (-40 °F) |
20 kA |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
21.9 J |
-55 °C (-67 °F) |
Nickel |
35 A |
Box |
0.205 in (5.2 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
8 A |
End Cap |
209.88 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
209.88 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
8 A |
End Cap |
209.88 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
209.88 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.6 A |
End Cap |
1.005 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
20 ms |
1.005 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
16 A |
End Cap |
462.5 J |
-55 °C (-67 °F) |
Tin |
750 A |
462.5 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; PSE; SEMKO; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
250 V |
100 mA |
Wraparound |
980 μJ |
-40 °C (-40 °F) |
Matte Tin Over Nickel |
4 kA |
4 h |
Rated Breaking Capacity at 250 VDC: 4000 A |
0.0009 |
Tape And Reel |
0.119 in (3.02 mm) |
e3 |
250 V |
0.119 x 0.331 in (3.02 x 8.4 mm) |
0.331 in (8.4 mm) |
UL |
125 °C (257 °F) |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
77 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
77 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
25 A |
Pin Wire |
1.45 kJ |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 400 A |
1450 |
Bulk |
0.275 in (6.99 mm) |
e3 |
250 V |
3AB |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CE; CUL; KC; PSE; UL |
125 °C (257 °F) |
Fast |
||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1.5 A |
Wraparound |
4.7 J |
-55 °C (-67 °F) |
Gold |
50 A |
2 ms |
4.7 |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
125 V |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CUL; UL |
125 °C (257 °F) |
Slow |
|||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
250 mA |
Wraparound |
15.8 mJ |
-55 °C (-67 °F) |
Gold |
50 A |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
5 s |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
2.5 A |
Wraparound |
1.029 J |
-55 °C (-67 °F) |
Gold with Nickel barrier |
50 A |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
72 V |
25 A |
Wraparound |
45 J |
-55 °C (-67 °F) |
Silver |
100 A |
Rated Breaking Capacity at 72 VDC: 500 A |
45 |
Tape And Reel |
0.397 in (10.08 mm) |
0.12 in (3.05 mm) |
e4 |
125 V |
0.398 x 0.123 x 0.123 in (10.1 x 3.12 x 3.12 mm) |
0.12 in (3.05 mm) |
CSA; CUL; PSE; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
12 A |
Wraparound |
20.341 J |
-55 °C (-67 °F) |
Tin Over Nickel |
150 A |
4 h |
20.341 |
Tape And Reel |
0.126 in (3.2 mm) |
0.064 in (1.63 mm) |
e3 |
32 V |
3.21 mΩ |
1206 |
0.126 x 0.064 x 0.033 in (3.2 x 1.63 x 0.835 mm) |
0.033 in (0.835 mm) |
CSA; UL |
150 °C (302 °F) |
Fast |
|||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
15 A |
Wraparound |
36.1 J |
-55 °C (-67 °F) |
Matte Tin Over Nickel |
150 A |
4 h |
36.1 |
Tape And Reel |
0.126 in (3.2 mm) |
0.064 in (1.62 mm) |
e3 |
32 V |
2.5 mΩ |
1206 |
0.126 x 0.064 x 0.032 in (3.2 x 1.62 x 0.82 mm) |
0.032 in (0.82 mm) |
CSA; UL |
150 °C (302 °F) |
Fast |
|||||||
|
Bel Fuse |
Electric Fuse |
Surface Mount |
250 V |
125 V |
40 A |
Wraparound |
1 kJ |
-55 °C (-67 °F) |
100 A |
1 m |
Rated Breaking Capacity at 125 VDC: 1000 A |
Tape And Reel, 13 inch |
0.386 in (9.8 mm) |
0.12 in (3.05 mm) |
250 V |
3912 |
0.12 in (3.05 mm) |
AEC-Q200; CUL; CE; UL |
125 °C (257 °F) |
|||||||||||
|
Bel Fuse |
Electric Fuse |
100 mA |
-55 °C (-67 °F) |
Matte Tin |
35 A |
Tape And Reel |
0.329 in (8.35 mm) |
e3 |
250 V |
Micro |
0.329 x 0.303 in (8.35 x 7.7 mm) |
0.303 in (7.7 mm) |
CSA, SEMKO, UL, VDE |
125 °C (257 °F) |
Fast |
|||||||||||||||
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
250 V |
63 V |
5 A |
Pin Wire |
94 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Bulk |
0.329 in (8.35 mm) |
0.157 in (4 mm) |
e3 |
20 ms |
Micro |
0.329 x 0.157 x 0.307 in (8.35 x 4 x 7.8 mm) |
0.307 in (7.8 mm) |
CCC, CQC, CUL, IEC60127-3, PSE, UL, VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
1 KV |
300 A |
Tab/Blade |
17 kJ |
-40 °C (-40 °F) |
Tin |
50 kA |
Bulk |
2.913 in (74 mm) |
1.772 in (45 mm) |
e3 |
0.984 in (25 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
25 A |
End Cap |
10 kA |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
2.5 A |
End Cap |
10 kA |
0.406 in (10.31 mm) |
500 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
3 A |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
160 A |
Tab/Blade |
6.25 kJ |
150 kA |
1.929 in (49 mm) |
1.181 in (30 mm) |
Indicator |
1.929 x 1.181 x 2.362 in (49 x 30 x 60 mm) |
2.362 in (60 mm) |
CE; DIN 43620; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
32 A |
Tab/Blade |
32 J |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
1.89 in (48 mm) |
1.89 x 0.752 in (48 x 19.1 mm) |
0.752 in (19.1 mm) |
BS 88; CE |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.