Fuses

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

BK/PCB-2-R

Cooper Electronic Technologies

Electric Fuse

Through Hole Mount

250 V

450 V

2 A

Pin Wire

200 mJ

50 A

PC

Rated Breaking Capacity at 450 VDC: 300 A

Box

0.35 in (8.89 mm)

0.35 x 0.375 in (8.89 x 9.53 mm)

0.375 in (9.53 mm)

CSA; UL

BK/S505-6.3-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

197 J

Nickel

1.5 kA

111

Box

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; EK; FIMKO; IMQ; PSE; SEMKO; UL; VDE

Time Delay

BK1/ABC-15-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

15 A

End Cap

200.2 J

Nickel

750 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK1/ABC-20-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

550.8 J

Nickel

400 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK1/GMA-1-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

480 mJ

Nickel

35 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

0.48

Bag

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; PSE; UL

Fast

BK8/ABC-15-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

15 A

End Cap

200.2 J

Nickel

750 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK8/ABC-20-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

550.8 J

Nickel

400 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BKPCB-2

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

450 V

2 A

Pin Wire

200 mJ

50 A

10 s

Rated Breaking Capacity at 450 VDC: 300 A

Box

0.35 in (8.89 mm)

0.184 in (4.67 mm)

250 V

0.345 in (8.77 mm)

CUL; UL

Fast

BKPCB-2-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

450 V

2 A

Pin Wire

200 mJ

50 A

10 s

Rated Breaking Capacity at 450 VDC: 300 A

Box

0.35 in (8.89 mm)

0.184 in (4.67 mm)

250 V

0.35 x 0.184 x 0.345 in (8.89 x 4.67 x 8.77 mm)

0.345 in (8.77 mm)

CUL; UL

Fast

BP/ATM-10-RP

Eaton Corporation

Electric Fuse

10 A

Tab/Blade

-40 °C (-40 °F)

Silver

1 kA

0.43 in (10.92 mm)

0.15 in (3.81 mm)

e4

32 V

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

UL

100 °C (212 °F)

Fast

C10G2

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

2 A

End Cap

120 kA

C10

0.394 in (10 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

C14G16

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

690 V

16 A

End Cap

80 kA

C14

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

C14M20I

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

20 A

End Cap

120 kA

C14

0.551 in (14 mm)

Indicator

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

C1Q1

Bel Fuse

Electric Fuse

Surface Mount

125 V

63 V

1 A

Wraparound

4 mJ

-55 °C (-67 °F)

Matte Tin Over Nickel

100 A

Rated Breaking Capacity at 63 VDC: 50 A

Tape And Reel

0.126 in (3.2 mm)

0.062 in (1.58 mm)

e3

125 V

1206

0.126 x 0.062 x 0.023 in (3.2 x 1.58 x 0.58 mm)

0.023 in (0.58 mm)

CE; CSA; UL

125 °C (257 °F)

Very Fast

C1S1

Bel Fuse

Electric Fuse

Surface Mount

63 V

63 V

1 A

Wraparound

121 mJ

-55 °C (-67 °F)

Tin with Nickel barrier

50 A

2 ms

Pre-Arcing Time: Open within 0.002 s, at 800% Rated Current

Tape And Reel

0.126 in (3.2 mm)

0.062 in (1.58 mm)

e3

63 V

1206

0.126 x 0.062 x 0.023 in (3.2 x 1.58 x 0.58 mm)

0.023 in (0.58 mm)

CE; CUL; UL

125 °C (257 °F)

Slow

C22G80I

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

80 A

End Cap

120 kA

C22

0.866 in (22 mm)

Indicator

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

CB61F8A-TR

Cooper Industries

Electric Fuse

Surface Mount

125 V

125 V

8 A

Wraparound

19.5 J

100 A

CB61F

Rated Breaking Capacity at 125 VDC: 300 A

Tape And Reel

0.24 in (6.1 mm)

0.101 in (2.57 mm)

0.24 x 0.101 x 0.101 in (6.1 x 2.57 x 2.57 mm)

0.101 in (2.57 mm)

CQC; PSE; UL

Fast

CC12H1A-TR

Eaton Corporation

Electric Fuse

Surface Mount

63 V

1 A

Wraparound

180 mJ

-55 °C (-67 °F)

50 A

100 ms

Pre Arcing Time: Open within 0.1 s at 300% Rated Current

0.18

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

63 V

1206

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.026 in (0.65 mm)

AEC-Q200; CUL; UL

125 °C (257 °F)

CC12M10A

Eaton Corporation

Electric Fuse

Surface Mount

24 V

10 A

Wraparound

2 J

-55 °C (-67 °F)

Tin with Nickel barrier

150 A

5 s

Pre Arcing Time: Open within 5 s at 350% Rated Current

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

24 V

4.5 mΩ

1206

0.035 in (0.89 mm)

CUL; UL

125 °C (257 °F)

CCMR003.HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

286 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CCMR02.5TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.5 A

End Cap

192 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CCMR025.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

25 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CY14X51G20

Littelfuse

Electric Fuse

Inline/Holder

690 V

20 A

End Cap

80 kA

0.551 in (14 mm)

690 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Fast

CY14X51M20

Littelfuse

Electric Fuse

Inline/Holder

690 V

20 A

End Cap

80 kA

0.551 in (14 mm)

690 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Time Lag

DEO125

Eaton Corporation

Electric Fuse

Inline/Holder

415 V

125 A

Tab/Blade

29.5 kJ

Box

1.22 in (31 mm)

1.22 x 1.85 in (31 x 47 mm)

1.85 in (47 mm)

BS 88; IEC

DFJ-80

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

450 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 450 VDC: 100000 A

1.13 in (28.7 mm)

1.13 x 2.63 in (28.7 x 66.8 mm)

2.63 in (66.8 mm)

CSA; UL

Fast

E86727-000

TE Connectivity

Electric Fuse

Surface Mount

32 V

5 A

Wraparound

5.3 J

50 A

UL

125 °C (257 °F)

Slow

ECNR60

Eaton Corporation

Electric Fuse

EV1K080.ZXBD

Littelfuse

Electric Fuse

Inline/Holder

1 KV

80 A

Tab/Blade

1.58 kJ

-40 °C (-40 °F)

30 kA

Bulk

1 in (25.4 mm)

2.875 in (73.03 mm)

125 °C (257 °F)

EYP2BH115

Panasonic

Thermal Fuse

Through Hole Mount

250 V

2 A

Wire

Tin

Bulk

0.197 in (5 mm)

0.087 in (2.2 mm)

e3

250 V

0.157 in (4 mm)

BEAB; CCC; CSA; PSE; UL; VDE

80 °C (176 °F)

EYP2BN082

Panasonic

Thermal Fuse

Through Hole Mount

250 V

2 A

Wire

Tin

Bulk

0.098 in (2.5 mm)

e3

250 V

BEAB; CCC; CSA; PSE; UL; VDE

60 °C (140 °F)

EYP2BN134

Panasonic

Thermal Fuse

Through Hole Mount

250 V

2 A

Wire

Tin

Bulk

0.098 in (2.5 mm)

e3

250 V

BEAB; CCC; CSA; PSE; UL; VDE

100 °C (212 °F)

F60C500V30AS

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

30 A

End Cap

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

MIL-PRF-15160/60

FLM2

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Slow

FLSR.100ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

Indicator

1.311 x 7.874 in (33.3 x 200 mm)

7.874 in (200 mm)

CSA; QPL; UL

Time Delay

FLSR.100T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLSR.100TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

Indicator

5 in (127 mm)

CSA; UL

Time Delay

FLSR004.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLSR075.VXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

75 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.283 in (32.6 mm)

Indicator

7.874 in (200 mm)

CSA; UL

Time Delay

FLSR100.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.283 in (32.6 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

FLSR100.VXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.283 in (32.6 mm)

Indicator

7.874 in (200 mm)

CSA; UL

Time Delay

FLSR100ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

Indicator

1.311 x 7.874 in (33.3 x 200 mm)

7.874 in (200 mm)

CSA; QPL; UL

Time Delay

FNA-15

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

15 A

End Cap

Silver

10 kA

1.5 in (38.1 mm)

0.817 in (20.75 mm)

e4

125 V

0.406 x 0.817 x 1.5 in (10.31 x 20.75 x 38.1 mm)

0.406 in (10.31 mm)

CSA, UL

Time Lag

FNQ-2-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

2.25 A

End Cap

Nickel

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FR10GR69V1

Mersen S A

Electric Fuse

Inline/Holder

690 V

1 A

End Cap

170 mJ

160 kA

Bulk

0.406 in (10.3 mm)

0.406 x 1.496 in (10.3 x 38 mm)

1.496 in (38 mm)

CCC; CE; CSA; IEC; UL

Very Fast

FRN-R-100

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

100 A

Tab/Blade

200 kA

10 s

Box

1.06 in (26.924 mm)

RK5

250 V

1.06 x 5.88 in (26.92 x 149.35 mm)

5.88 in (149.352 mm)

CE; CSA; UL

Time Delay

FRN-R-300

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 V

300 A

Tab/Blade

200 kA

10 s

Rated Breaking Capacity at 250 VDC: 20000 A

Box

2.38 in (60.452 mm)

RK5

250 V

2.38 x 8.63 in (60.45 x 219.2 mm)

8.63 in (219.202 mm)

CE; CSA; UL

Time Delay

FRN-R-450

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 V

450 A

Tab/Blade

200 kA

10 s

Rated Breaking Capacity at 250 VDC: 20000 A

Box

2.88 in (73.152 mm)

RK5

250 V

2.88 x 10.38 in (73.15 x 263.65 mm)

10.38 in (263.652 mm)

CE; CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.