Fuses

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

5019906.16

Siba

Electric Fuse

Inline/Holder

1 KV

1 KV

16 A

End Cap

30 J

30 kA

Bulk

0.394 in (10 mm)

1 ms

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

UL

5MF4-R

Bel Fuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

22 J

-55 °C (-67 °F)

Nickel

10 kA

5 s

Bulk

0.201 in (5.1 mm)

125 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.201 x 0.787 in (5.1 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Fast

6CT

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

6 A

Tab/Blade

1.8 J

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

2.157 in (54.8 mm)

2.157 x 0.343 in (54.8 x 8.7 mm)

0.343 in (8.7 mm)

BS 88; CE

6C/T

Altech

Electric Fuse

Inline/Holder

380 V

6 A

End Cap

Bulk

0.335 in (8.5 mm)

Indicator

1.26 in (32 mm)

CEI, IEC

Slow

7010.7070.37

Schurter Ag

Electric Fuse

Through Hole Mount

125 V

1 A

Pin Wire

300 mJ

-55 °C (-67 °F)

Tin

50 A

Tape And Reel, 13 inch

0.093 in (2.36 mm)

e3

4 ms

0.091 x 0.315 in (2.3 x 8 mm)

0.093 x 0.315 in (2.36 x 8 mm)

0.315 in (8 mm)

CSA; GAMT1; UL

85 °C (185 °F)

Very Fast

7012540.10

Siba

Electric Fuse

Inline/Holder

600 V

10 A

End Cap

12 J

Nickel

50 kA

Bulk

0.25 in (6.35 mm)

1 ms

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

Very Fast

7017240.0,5

Siba

Electric Fuse

Inline/Holder

1 KV

1 KV

500 mA

End Cap

120 mJ

30 kA

Bulk

0.25 in (6.35 mm)

6 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Very Fast

8020.0603

Schurter Ag

Electric Fuse

Inline/Holder

250 V

12 A

End Cap

72 J

-40 °C (-40 °F)

500 A

Box

0.25 in (6.35 mm)

5 s

3AB

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.0603.G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

12 A

End Cap

72 J

-40 °C (-40 °F)

500 A

Bulk

0.25 in (6.35 mm)

5 s

3AB

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.0603.H

Schurter Ag

Electric Fuse

Inline/Holder

250 V

100 V

12 A

End Cap

788 J

-40 °C (-40 °F)

Nickel

500 A

Bulk

0.25 in (6.35 mm)

5 s

3AG

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.0603.H.PT

Schurter Ag

Electric Fuse

Through Hole Mount

250 V

100 V

12 A

Pin Wire

788 J

-40 °C (-40 °F)

500 A

Bulk

0.27 in (6.85 mm)

5 s

3AG

1.291 in (32.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.0603G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

12 A

End Cap

72 J

-40 °C (-40 °F)

500 A

Bulk

0.25 in (6.35 mm)

5 s

3AB

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.2090

Schurter Ag

Electric Fuse

Through Hole Mount

1 KV

10 A

Pin Wire

62 J

-40 °C (-40 °F)

20 kA

Bulk

0.425 in (10.8 mm)

30 ms

0.406 x 1.496 in (10.3 x 38 mm)

1.531 in (38.9 mm)

UL

125 °C (257 °F)

AAO16

Eaton Corporation

Electric Fuse

Inline/Holder

550 V

16 A

Tab/Blade

120 J

80 kA

Box

0.539 in (13.7 mm)

0.539 x 1.378 in (13.7 x 35 mm)

1.378 in (35 mm)

IEC

ABC-1/2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

500 mA

End Cap

39 mJ

Nickel

35 A

4 h

Rated Breaking Capacity at 125 VDC: 10000 A

0.25 in (6.35 mm)

250 V

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

ABC-12-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

12 A

End Cap

133.3 J

Nickel

750 A

Rated Breaking Capacity at 125 VDC: 10000 A

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

AGW-4

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

4 A

End Cap

Nickel

100 A

0.252 in (6.4 mm)

32 V

0.252 x 0.874 in (6.4 x 22.2 mm)

0.874 in (22.2 mm)

Fast

AGW4

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

4 A

End Cap

0.25 in (6.35 mm)

32 V

7AG

0.875 in (22.225 mm)

AGX-15

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

15 A

End Cap

Nickel

200 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

0.25 in (6.35 mm)

250 V

0.248 x 1 in (6.3 x 25.4 mm)

0.252 x 1 in (6.4 x 25.4 mm)

1 in (25.4 mm)

CSA; UL

Fast

AGX-3

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

Nickel

100 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

0.25 in (6.35 mm)

250 V

0.248 x 1 in (6.3 x 25.4 mm)

0.252 x 1 in (6.4 x 25.4 mm)

1 in (25.4 mm)

CUL

Fast

AGX-3/4

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

750 mA

End Cap

Nickel

35 A

Pre Arcing Time: Open within 5 s at 200% Rated Current

0.25 in (6.35 mm)

250 V

0.248 x 1 in (6.3 x 25.4 mm)

0.252 x 1 in (6.4 x 25.4 mm)

1 in (25.4 mm)

CUL

Fast

AGX3

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

3 A

End Cap

0.25 in (6.35 mm)

32 V

8AG

1 in (25.4 mm)

ANL-130

Eaton Corporation

Electric Fuse

Inline/Holder

80 V

130 A

End Cap

2.7 kA

3.189 in (81 mm)

Indicator

3.189 x 0.874 in (81 x 22.2 mm)

0.874 in (22.2 mm)

CSA; UL

Time Delay

ANL-50

Eaton Corporation

Electric Fuse

Inline/Holder

80 V

50 A

Tab/Blade

2.7 kA

3.189 in (81 mm)

80 V

Indicator

3.189 x 0.874 in (81 x 22.2 mm)

0.874 in (22.2 mm)

CSA; UL

Time Delay

ATM1

Mersen S A

Electric Fuse

Inline/Holder

600 V

600 V

1 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 100000 A

0.394 in (10 mm)

600 V

Midget

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Fast

ATMR25

Mersen S A

Electric Fuse

Inline/Holder

600 V

600 V

25 A

End Cap

200 kA

Rated Breaking Capacity = 33.75A-10kA

Bulk

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

ATMR4

Mersen S A

Electric Fuse

Inline/Holder

600 V

4 A

End Cap

200 kA

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

ATQ1

Mersen S A

Electric Fuse

Inline/Holder

500 V

1 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ1/10

Mersen S A

Electric Fuse

Inline/Holder

500 V

100 mA

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ1/2

Mersen S A

Electric Fuse

Inline/Holder

500 V

500 mA

End Cap

10 kA

0.394 in (10 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ1/8

Mersen S A

Electric Fuse

Inline/Holder

500 V

125 mA

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ12

Mersen S A

Electric Fuse

Inline/Holder

500 V

12 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ8

Mersen S A

Electric Fuse

Inline/Holder

500 V

8 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

BAF-25

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

25 A

End Cap

200 A

Bulk

0.406 in (10.3 mm)

CC

250 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE

Fast

BAO63

Eaton Corporation

Electric Fuse

Inline/Holder

550 V

63 A

Tab/Blade

6.7 kJ

80 kA

Box

0.827 in (21 mm)

0.827 x 2.126 in (21 x 54 mm)

2.126 in (54 mm)

IEC

BBS-30

Eaton Corporation

Electric Fuse

30 A

End Cap

0.41 in (10.41 mm)

48 V

0.41 x 1.38 in (10.41 x 35.05 mm)

1.38 in (35.05 mm)

CE

Fast

BK-AGC-20-R

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

20 A

End Cap

2.44 kJ

-55 °C (-67 °F)

Nickel

1 kA

Pre Arcing Time: Open within 120 s at 200% Rated Current

1.438

Box

0.25 in (6.35 mm)

32 V

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

125 °C (257 °F)

Fast

BK-AGC-5-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

131.5 J

-55 °C (-67 °F)

Nickel

200 A

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.045

Box

0.25 in (6.35 mm)

250 V

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

125 °C (257 °F)

Fast

BK-GMC-3-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

19 J

Nickel

100 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; KC; MITI; UL

Time Delay

BK-S505-6-3-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

111 J

-55 °C (-67 °F)

1.5 kA

Bulk

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CSA, CUL, IMQ, KC, PSE, SEMKO, UL, VDE

125 °C (257 °F)

Time Delay

BK/ABC-25-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

25 A

End Cap

839.3 J

Nickel

200 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK/AGC-20-R

Cooper Industries

Electric Fuse

Inline/Holder

32 V

20 A

End Cap

1.438 J

Nickel

1 kA

AGC

Box

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK/AGC-5-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

45 mJ

Nickel

200 A

0.04

Box

0.25 in (6.35 mm)

250 V

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK/AGX-30

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

30 A

End Cap

Nickel

100 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

Box

0.25 in (6.35 mm)

125 V

0.248 x 1 in (6.3 x 25.4 mm)

0.25 x 1.042 in (6.35 x 26.47 mm)

1 in (25.4 mm)

CSA; UL

Fast

BK/GBB-30-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

30 A

End Cap

Nickel

200 A

Rated Breaking Capacity at 125 VDC: 200 A

Box

0.25 in (6.35 mm)

250 V

0.236 x 1.26 in (6 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Very Fast

BK/GDA-50MA

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

50 mA

End Cap

1.7 mJ

Nickel

1.5 kA

0.0017

Box

0.205 in (5.2 mm)

250 V

3 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CSA; IMQ; SEMKO; UL

Fast

BK/GMC-3-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

19 J

Nickel

100 A

GMC

Box

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CSA; MITI; UL

Medium Time Delay

BK/PCB-2

Cooper Industries

Electric Fuse

Through Hole Mount

250 V

450 V

2 A

Pin Wire

200 mJ

50 A

Rated Breaking Capacity at 450 VDC: 5900 A

Box

0.35 in (8.89 mm)

0.184 in (4.67 mm)

250 V

150 mΩ

0.35 x 0.184 x 0.375 in (8.89 x 4.67 x 9.53 mm)

0.375 in (9.53 mm)

CSA; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.