Fuses

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

MIC2005.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

17 J

-40 °C (-40 °F)

1 kA

20 ms

Bulk

0.358 in (9.1 mm)

0.15 in (3.8 mm)

Micro

0.311 in (7.9 mm)

125 °C (257 °F)

MST3.15A250V

Spc Technology/ Multicomp

Electric Fuse

Through Hole Mount

250 V

250 V

3.15 A

Pin Wire

84.341 J

-55 °C (-67 °F)

100 A

0.329 in (8.35 mm)

0.169 in (4.3 mm)

20 ms

0.329 x 0.169 x 0.303 in (8.35 x 4.3 x 7.7 mm)

0.303 in (7.7 mm)

125 °C (257 °F)

Slow

NON-150

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

150 A

Tab/Blade

10 kA

Rated Breaking Capacity at 125 VDC: 10000 A

Box

1.56 in (39.62 mm)

H

250 V

1.56 x 7.13 in (39.62 x 181.1 mm)

7.13 in (181.1 mm)

CE; CSA; UL

PSR030FL0200Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

200 A

Threaded

3.012 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR070FS0160Z

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

160 A

Threaded

2.377 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.913 in (74 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

PV-15A10F

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

15 A

End Cap

22 J

-40 °C (-40 °F)

50 kA

Box

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

0.409 x 1.516 in (10.4 x 38.5 mm)

1.496 in (38 mm)

CCC; CSA; IEC; UL

90 °C (194 °F)

RES-60

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

60 A

End Cap

10 kA

Box

1.06 in (26.92 mm)

5.5 in (139.7 mm)

RF1567-000

TE Connectivity

Electric Fuse

Surface Mount

32 V

3.5 A

Wraparound

730 mJ

35 A

UL

125 °C (257 °F)

Very Fast

SC-2

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

170 V

2 A

End Cap

100 kA

Rated Breaking Capacity at 170 VDC: 10000 A

Box

0.406 in (10.3 mm)

G

600 V

0.406 x 1.31 in (10.3 x 33.27 mm)

1.31 in (33.27 mm)

CSA; UL

Fast

SC-3

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

170 V

3 A

End Cap

100 kA

Rated Breaking Capacity at 170 VDC: 10000 A

Box

0.406 in (10.3 mm)

G

600 V

0.406 x 1.31 in (10.3 x 33.27 mm)

1.31 in (33.27 mm)

CSA; UL

Fast

SF-1206S200M-2

Bourns

Electric Fuse

Surface Mount

63 V

2 A

Wraparound

75.8 mJ

-55 °C (-67 °F)

50 A

50 ms

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

1 ms

1206

0.126 x 0.063 x 0.038 in (3.2 x 1.6 x 0.97 mm)

0.038 in (0.97 mm)

UL

125 °C (257 °F)

Slow

SF-1206SP700-2

Bourns

Electric Fuse

Surface Mount

32 V

7 A

Wraparound

10.17 J

-20 °C (-4 °F)

Tin Over Nickel

50 A

1 s

Tape And Reel, 7 inch

0.122 in (3.1 mm)

0.061 in (1.55 mm)

e3

1206

0.024 in (0.6 mm)

UL

105 °C (221 °F)

Time Lag

SPFJ450.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

450 A

Tab/Blade

565.333 kJ

200 kA

14 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

2.5 in (63.5 mm)

Midget

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE; IEC; UL; VDE

T-3

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

3 A

10 kA

Box

CE; CSA; UL

Time Delay

TDC600-10A

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

10 A

End Cap

Silver

200 A

0.248 in (6.3 mm)

e4

0.248 x 1 in (6.3 x 25.4 mm)

1 in (25.4 mm)

UL

Fast

TR2/C515S-250-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

250 mA

Pin Wire

467 mJ

-55 °C (-67 °F)

Tin

35 A

3 s

Pre Arcing Time: Open within 3 s at 200% Rated Current

Tape And Reel

0.217 in (5.5 mm)

e3

250 V

3 s

0.197 x 0.591 in (5 x 15 mm)

0.217 x 0.598 in (5.5 x 15.2 mm)

0.598 in (15.2 mm)

CSA, UL

85 °C (185 °F)

Time Delay

TR2/C515S-500-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

500 mA

Pin Wire

2.28 J

-55 °C (-67 °F)

Tin

35 A

3 s

Pre Arcing Time: Open within 3 s at 200% Rated Current

Tape And Reel

0.217 in (5.5 mm)

e3

250 V

3 s

0.197 x 0.591 in (5 x 15 mm)

0.217 x 0.598 in (5.5 x 15.2 mm)

0.598 in (15.2 mm)

CSA, UL

85 °C (185 °F)

Time Delay

TR2/C515S-750-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

750 mA

Pin Wire

9.162 J

-55 °C (-67 °F)

Tin

35 A

3 s

Pre Arcing Time: Open within 3 s at 200% Rated Current

Tape And Reel

0.217 in (5.5 mm)

e3

250 V

3 s

0.197 x 0.591 in (5 x 15 mm)

0.217 x 0.598 in (5.5 x 15.2 mm)

0.598 in (15.2 mm)

CSA, UL

85 °C (185 °F)

Time Delay

TR2/C515S-800-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

800 mA

Pin Wire

10.544 J

-55 °C (-67 °F)

Tin

35 A

3 s

Pre Arcing Time: Open within 3 s at 200% Rated Current

Tape And Reel

0.217 in (5.5 mm)

e3

250 V

3 s

0.197 x 0.591 in (5 x 15 mm)

0.217 x 0.598 in (5.5 x 15.2 mm)

0.598 in (15.2 mm)

CSA, UL

85 °C (185 °F)

Time Delay

V300697

Mersen S A

Electric Fuse

Inline/Holder

690 V

200 A

Tab/Blade

2.6 kJ

200 kA

Bulk

1.874 in (47.6 mm)

2.008 in (51 mm)

Indicator

2.224 in (56.5 mm)

CCC; CE; CSA; EAC; IEC; UL; VDE

Ultra Fast

0001.2505

Schurter Ag

Electric Fuse

Inline/Holder

250 V

300 V

1.25 A

End Cap

1.86 J

-55 °C (-67 °F)

Nickel

1.5 kA

Rated Breaking Capacity at 300 VDC: 1500 A

1.86

Box

0.205 in (5.2 mm)

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; KTL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0001.2716.11

Schurter Ag

Electric Fuse

Inline/Holder

250 V

125 V

16 A

End Cap

1.272 kJ

-55 °C (-67 °F)

Gold

500 A

Rated Breaking Capacity at 125 VDC: 1500 A

Bulk

0.205 in (5.2 mm)

e4

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

125 °C (257 °F)

Time Lag

0034.3120G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

16 J

-55 °C (-67 °F)

Nickel

35 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.3120.G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

16 J

-55 °C (-67 °F)

Nickel

35 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.3122

Schurter Ag

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

47 J

-55 °C (-67 °F)

Nickel

35 A

Box

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.3123G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

68.3 J

-55 °C (-67 °F)

Nickel

40 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.3123.G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

68.3 J

-55 °C (-67 °F)

Nickel

40 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.6705

Schurter Ag

Electric Fuse

Through Hole Mount

250 V

63 V

100 mA

Pin Wire

80 mJ

-55 °C (-67 °F)

Tin

35 A

0.08

Bulk

0.335 in (8.5 mm)

e3

20 ms

0.335 x 0.335 in (8.5 x 8.5 mm)

0.335 in (8.5 mm)

CCC; CUL; KTL; UL; VDE

125 °C (257 °F)

Time Lag

0034.6918

Schurter Ag

Electric Fuse

Through Hole Mount

250 V

2 A

Pin Wire

16 J

-40 °C (-40 °F)

Tin

100 A

Bag

0.335 in (8.5 mm)

e3

20 ms

0.335 x 0.354 in (8.5 x 9 mm)

0.335 in (8.5 mm)

CCC; CUL; KTL; METI; UL; VDE

85 °C (185 °F)

Time Lag

0157.125.DR

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

125 mA

Wraparound

2.86 mJ

-55 °C (-67 °F)

Gold

50 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

UL

125 °C (257 °F)

Very Fast

0157.125DR

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

125 mA

Wraparound

2.86 mJ

-55 °C (-67 °F)

Matte Tin

50 A

5 s

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e3

Nano

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

UL

125 °C (257 °F)

Very Fast

0157.750.DR

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

750 mA

Wraparound

185 mJ

-55 °C (-67 °F)

Silver

50 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

UL

125 °C (257 °F)

Very Fast

0157.750DR

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

750 mA

Wraparound

185 mJ

-55 °C (-67 °F)

Matte Tin

50 A

5 s

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e3

Nano

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

UL

125 °C (257 °F)

Very Fast

0157005.DRT

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

5 A

Wraparound

53.72 J

-55 °C (-67 °F)

Matte Tin

50 A

100 ms

Tape And Reel

0.256 in (6.5 mm)

0.106 in (2.69 mm)

e3

Nano

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

CUL; PSE; UL

125 °C (257 °F)

Time Lag

0157005DRT

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

5 A

Wraparound

53.72 J

-55 °C (-67 °F)

Matte Tin

50 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e3

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

PSE; UL

125 °C (257 °F)

Time Lag

01571.25DR

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

1.25 A

Wraparound

664 mJ

-55 °C (-67 °F)

Silver

50 A

5 s

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

Nano

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

PSE; UL

125 °C (257 °F)

Very Fast

0213.315MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

315 mA

Pin Wire

1.14 J

-55 °C (-67 °F)

Tin

35 A

20 ms

1.14

Bulk

0.217 in (5.5 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.846 in (21.5 mm)

CCC; CE; CSA; IEC; SEV; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

02130.25MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

555 mJ

-55 °C (-67 °F)

35 A

20 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

02130.63MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

4.8 J

-55 °C (-67 °F)

35 A

20 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

021302.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

138 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

138

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEV; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

021306.3MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

600 J

-55 °C (-67 °F)

Nickel

63 A

20 ms

600

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEV; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

02133.15MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

3.15 A

Pin Wire

202 J

-55 °C (-67 °F)

Tin

35 A

20 ms

202

Bulk

0.217 in (5.5 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.846 in (21.5 mm)

CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0216005.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

5 A

Pin Wire

27.46 J

-55 °C (-67 °F)

Matte Tin

1.5 kA

20 ms

27.46

Bulk

0.228 in (5.8 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.886 in (22.5 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Fast

0216005MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

250 V

5 A

Wire

27.46 J

-55 °C (-67 °F)

Tin

1.5 kA

10 ms

Bulk

0.228 in (5.8 mm)

e3

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CCC, CE, CSA, PSE, UL, VDE

125 °C (257 °F)

Fast

0217.500HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

215 mJ

-55 °C (-67 °F)

Nickel

35 A

10 ms

0.215

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CE; CSA; IEC; KC; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Very Fast

0218.100MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

79 mJ

-55 °C (-67 °F)

Nickel

35 A

10 ms

0.079

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; KC; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0218.250MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

540.5 mJ

-55 °C (-67 °F)

Tin

35 A

0.5405

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0218.250TXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

540.5 mJ

-55 °C (-67 °F)

Matte Tin

35 A

20 ms

0.5405

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CE, CSA, KC, SEMKO, UL, VDE

125 °C (257 °F)

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.