Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
125 V |
1 A |
Wraparound |
2.8 J |
-40 °C (-40 °F) |
Gold |
200 A |
Rated Breaking Capacity at 125 VDC: 100 A |
Bag |
0.445 in (11.3 mm) |
0.165 in (4.2 mm) |
e4 |
10 ms |
0.165 x 0.437 in (4.2 x 11.1 mm) |
0.421 x 0.142 x 0.157 in (10.7 x 3.6 x 4 mm) |
0.157 in (4 mm) |
CUL; UL; VDE |
85 °C (185 °F) |
Time Lag |
||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
32 V |
63 V |
1 A |
Wraparound |
42 mJ |
-55 °C (-67 °F) |
Gold Nickel |
50 A |
0.07 |
Tape |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
e4 |
60 s |
1206 |
0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm) |
0.024 in (0.6 mm) |
CUL, UL |
90 °C (194 °F) |
Very Fast |
||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
32 V |
63 V |
1.25 A |
Wraparound |
69 mJ |
-55 °C (-67 °F) |
Gold Nickel |
50 A |
0.12 |
Tape And Reel, 7 inch |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
e4 |
60 s |
1206 |
0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm) |
0.024 in (0.6 mm) |
CUL, UL |
90 °C (194 °F) |
Very Fast |
||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
350 A |
Tab/Blade |
15 kJ |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
1.969 in (50 mm) |
1.969 x 1.614 in (50 x 41 mm) |
1.614 in (41 mm) |
BS 88; CE |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
100 mA |
Pin Wire |
3.8 mJ |
-40 °C (-40 °F) |
Tin |
35 A |
20 ms |
Ammo Pack; Tape |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CCC; CE; CUL; VDE; UL |
85 °C (185 °F) |
Fast |
||||||||||
Eaton Corporation |
Electric Fuse |
Surface Mount |
125 V |
80 V |
400 A |
Tab/Blade |
2.5 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Very Fast |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
8.9 J |
Nickel |
100 A |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
Box |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CSA; KC; MITI; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
12 A |
End Cap |
Nickel |
1 kA |
Box |
0.25 in (6.35 mm) |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
269 mJ |
Nickel |
35 A |
Box |
0.25 in (6.35 mm) |
32 V |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
125 V |
10 A |
End Cap |
280 J |
Nickel |
200 A |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
Box |
0.205 in (5.2 mm) |
125 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
PSE; UL |
Fast |
|||||||||||||
|
Cooper Industries |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
8.9 J |
Nickel |
100 A |
GMC |
Box |
0.205 in (5.2 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CSA; MITI; UL |
Medium Time Delay |
|||||||||||||||
Cooper Industries |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
36 J |
35 A |
S504 |
Bulk |
0.205 in (5.2 mm) |
20 ms |
0.205 x 0.394 in (5.2 x 10 mm) |
0.394 in (10 mm) |
BSI; IMQ; SEMKO; UL; UR; VDE |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
315 mA |
End Cap |
621 mJ |
Nickel |
35 A |
0.621 |
Bag |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; IMQ; SEMKO; UL; VDE |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
3.15 A |
End Cap |
96.4 J |
Nickel |
35 A |
96.4 |
Bag |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; IMQ; PSE; SEMKO; UL; VDE |
Time Delay |
||||||||||||
|
Bel Fuse |
Electric Fuse |
Surface Mount |
125 V |
63 V |
250 mA |
Wraparound |
100 μJ |
-55 °C (-67 °F) |
Matte Tin Over Nickel |
100 A |
Rated Breaking Capacity at 63 VDC: 50 A |
Tape And Reel |
0.126 in (3.2 mm) |
0.062 in (1.58 mm) |
e3 |
125 V |
1206 |
0.126 x 0.062 x 0.023 in (3.2 x 1.58 x 0.58 mm) |
0.023 in (0.58 mm) |
CE; CSA; UL |
125 °C (257 °F) |
Very Fast |
||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
3.2 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
500 mA |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Box |
0.563 in (14.3 mm) |
RK5 |
250 V |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
12 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Box |
0.563 in (14.3 mm) |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
80 A |
End Cap |
600 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Emerson Electric |
Thermal Fuse |
Through Hole Mount |
250 V |
10 A |
Wire |
Tape And Reel, 14 inch |
0.157 in (4 mm) |
250 V |
0.579 in (14.7 mm) |
|||||||||||||||||||||
|
Eaton Corporation |
||||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
10 A |
End Cap |
200 kA |
0.563 in (14.3 mm) |
0.563 x 1.5 in (14.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Very Fast |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
300 mA |
End Cap |
11.1 mJ |
Nickel |
200 kA |
12 s |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
30 A |
End Cap |
100 kA |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA, UL |
Fast |
||||||||||||||||||||
Spc Technology/ Multicomp |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
2.5 A |
Pin Wire |
-55 °C (-67 °F) |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
0.11 in (2.8 mm) |
125 V |
1 s |
125 °C (257 °F) |
Very Fast |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
100 kA |
80 ms |
Bulk |
1.5 in (38.1 mm) |
2.843 in (72.2 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
70 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Vishay Intertechnology |
Electric Fuse |
Surface Mount |
32 V |
4 A |
Wraparound |
40.3 mJ |
15 °C (59 °F) |
Tin Over Nickel |
50 A |
0.0403 |
Tape And Reel |
0.061 in (1.55 mm) |
0.033 in (0.85 mm) |
e3 |
32 V |
19 mΩ |
0603 |
0.061 x 0.033 x 0.018 in (1.55 x 0.85 x 0.45 mm) |
0.018 in (0.45 mm) |
UL; UMF |
35 °C (95 °F) |
Very Fast |
||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
40 mA |
End Cap |
110 μJ |
Silver |
35 A |
0.205 in (5.2 mm) |
e4 |
250 V |
3600 s |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
Fast |
||||||||||||||
|
Conquer Electronics |
Electric Fuse |
Inline/Holder |
250 V |
800 mA |
End Cap |
2.24 J |
-55 °C (-67 °F) |
35 A |
Box |
0.181 in (4.6 mm) |
3 s |
0.181 x 0.571 in (4.6 x 14.5 mm) |
0.571 in (14.5 mm) |
CSA; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
160 A |
Tab/Blade |
60.1 kJ |
200 kA |
10 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
Midget |
1.5 x 3 in (38.1 x 76.2 mm) |
3.012 in (76.5 mm) |
CE; IEC; UL |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
|||||||||||||||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
300 V |
500 mA |
End Cap |
500 mJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Rated Breaking Capacity at 300 VDC: 1500 A |
0.5 |
Box |
0.205 in (5.2 mm) |
5 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CUL; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
11.68 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
10 ms |
11.68 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
500 mA |
Pin Wire |
365 mJ |
-55 °C (-67 °F) |
Tin |
35 A |
1 s |
Rated Breaking Capacity at 125 VDC: 10000 A |
0.365 |
Bulk |
0.189 in (4.8 mm) |
e3 |
250 V |
2AG |
0.185 x 0.57 in (4.7 x 14.48 mm) |
0.587 in (14.9 mm) |
CE, CSA, UL |
125 °C (257 °F) |
Fast |
|||||||
|
Littelfuse |
Electric Fuse |
5 A |
End Cap |
-55 °C (-67 °F) |
Tin |
100 A |
4 h |
17 |
0.189 in (4.8 mm) |
e3 |
250 V |
2AG |
0.189 x 0.587 in (4.8 x 14.9 mm) |
0.587 in (14.9 mm) |
CE, CSA, UL |
125 °C (257 °F) |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
2 A |
Pin Wire |
405 mJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
4 ms |
Rated Breaking Capacity at 125 VDC: 300 A |
Ammo Pack |
0.11 in (2.8 mm) |
e3 |
Pico |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CCC; CSA; PSE; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
200 mA |
Pin Wire |
-55 °C (-67 °F) |
Tin |
100 kA |
4 h |
Bulk |
0.235 in (5.97 mm) |
e3 |
125 V |
Micro |
0.235 x 0.287 in (5.97 x 7.3 mm) |
0.287 in (7.3 mm) |
CSA, UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
600 mA |
Pin Wire |
-55 °C (-67 °F) |
Tin |
100 kA |
4 h |
Bulk |
0.25 in (6.35 mm) |
e3 |
125 V |
Micro |
0.25 x 0.35 in (6.35 x 8.89 mm) |
0.35 in (8.89 mm) |
CSA, UL |
85 °C (185 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
10 A |
Tab/Blade |
115 J |
-40 °C (-40 °F) |
Tin |
1 kA |
80 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm) |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
10 A |
Tab/Blade |
115 J |
-40 °C (-40 °F) |
Tin |
1 kA |
80 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
3.2 A |
End Cap |
209 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
209 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KTL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
5 A |
End Cap |
25 J |
-55 °C (-67 °F) |
Nickel |
400 A |
5 s |
Rated Breaking Capacity at 125 VDC: 10000 A |
25 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Delay |
||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
45 V |
63 V |
5 A |
Wraparound |
2.3 J |
-55 °C (-67 °F) |
Matte Tin Over Nickel |
50 A |
1 s |
2.3 |
Tape And Reel |
0.126 in (3.2 mm) |
0.064 in (1.63 mm) |
e3 |
35 V |
1206 |
0.126 x 0.064 x 0.032 in (3.2 x 1.63 x 0.82 mm) |
0.033 in (0.835 mm) |
CSA; CUL; UL |
150 °C (302 °F) |
Fast |
|||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
45 V |
63 V |
5 A |
Wraparound |
2.3 J |
-55 °C (-67 °F) |
Matte Tin Over Nickel |
50 A |
1 s |
Tape And Reel |
0.126 in (3.2 mm) |
0.064 in (1.63 mm) |
e3 |
1206 |
0.033 in (0.835 mm) |
AEC-Q200; CSA; CUL; UL |
150 °C (302 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
12 V |
32 V |
2 A |
Wraparound |
149 mJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
4 h |
0.15 |
Tape And Reel |
0.061 in (1.54 mm) |
0.033 in (0.85 mm) |
e3 |
32 V |
51 mΩ |
0603 |
0.061 x 0.033 x 0.02 in (1.54 x 0.85 x 0.5 mm) |
0.02 in (0.5 mm) |
CSA; UL |
150 °C (302 °F) |
Fast |
||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
32 V |
5 A |
Wraparound |
4.761 J |
-55 °C (-67 °F) |
Tin Over Nickel |
50 A |
4 h |
0.065 |
Tape And Reel |
0.126 in (3.2 mm) |
0.064 in (1.63 mm) |
e3 |
32 V |
1206 |
0.126 x 0.064 x 0.032 in (3.2 x 1.63 x 0.82 mm) |
0.032 in (0.82 mm) |
CSA; UL |
150 °C (302 °F) |
||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1 A |
Wraparound |
602.9 mJ |
-55 °C (-67 °F) |
Gold |
50 A |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
5 s |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CE; CSA; PSE; TUV; UL |
125 °C (257 °F) |
Very Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.