Part | RoHS | Manufacturer | Connector Accessory Type | Connector Side-1 | Connector Side-2 | Rated Voltage | Rated Current | Shielding | Approvals (V) | Cross Section Area | Finish Thickness | Conductor Material | Construction | Minimum Wire Size | Jacket Material | Terminal Type | Resistance | Conductor Finish | MIL Conformity | Maximum Wire Size | Insulator Material | Maximum Operating Temperature | DIN Conformity | Application | Cable Types | IEC Conformity | Minimum Operating Temperature | Wire Gauge (AWG) | Design | Diameter | No. of Conductors | Mounting Style | Additional Features | Material | Mounting Option-2 | Length | Mounting Option-1 | Wire & Cable Name | Stranding | Rated DC Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FTDI |
CABLE ASSEMBLY |
USB |
5 V |
.25 A |
NO |
CE; FCC |
TIN |
85 Cel |
INPUT/OUTPUT APPLICATION |
-40 Cel |
24 |
5 mm |
6 |
FTDICHIP-ID |
5 mm |
COMMUNICATION CABLE |
|||||||||||||||||||||||
|
FTDI |
CABLE ASSEMBLY |
USB |
UART |
NO |
CE; UL |
NO |
85 Cel |
NO |
INSTRUMENTATION AND CONTROL USE |
NO |
-40 Cel |
24 |
5 mm |
6 |
1.8 mm |
CABLE ASSEMBLY |
|||||||||||||||||||||||
|
Tag-connect |
CABLE ASSEMBLY |
TAG6PIN |
RJ12 |
NO |
NO |
NO |
NO |
||||||||||||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
MIL-DTL-27500 |
COPPER ALLOY |
TIN |
22 AWG |
MODIFIED RADIATION CROSS-LINKED ETFE POLYMER |
150 Cel |
SPEC 55 |
-65 Cel |
22 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
600 V |
NO |
BS; CUL; DIN; IEC; UL; VDE |
.75 mm2 |
BARE COPPER |
STRANDED |
POLYMER |
NO |
POLYMER |
80 Cel |
NO |
FIXED INSTALLATION |
NO |
-40 Cel |
19 |
10.7 mm |
7 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||
|
FTDI |
CABLE ASSEMBLY |
USB |
UART |
NO |
UL |
85 Cel |
-40 Cel |
24 |
5 mm |
COMMUNICATION CABLE |
|||||||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE |
.09 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYL CHLORIDE |
.23 ohm |
TIN |
NO |
POLYVINYL CHLORIDE |
80 Cel |
NO |
QUICK AND ECONOMICAL, CONNECTION IN IDC-TECHNIQUE |
NO |
-20 Cel |
28 |
7.3 mm |
20 |
FLAT CABLE |
7X0.127 |
|||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE |
.09 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYL CHLORIDE |
.23 ohm |
TIN |
NO |
POLYVINYL CHLORIDE |
80 Cel |
NO |
QUICK AND ECONOMICAL, CONNECTION IN IDC-TECHNIQUE |
NO |
-20 Cel |
28 |
8.6 mm |
24 |
FLAT CABLE |
7X0.127 |
|||||||||||||||||
|
Habia Cable Ab |
WIRE AND CABLE |
600 V |
52 A |
NO |
MIL |
4 mm2 |
COPPER |
STRANDED |
.005 ohm |
TIN |
NO |
HFI140 |
120 Cel |
SEAGUARD PRODUCT, DEFENCE, HABIATRON AND RAILGUARD |
-30 Cel |
3.2 mm |
1 |
FLAME RESISTANT, LOW SMOKE GENERATION, STANDARD: DEF STAN 61-12 PART 18 |
FLEXIBLE CORD AND FIXTURE WIRE |
56X0.300 |
|||||||||||||||||||
|
Habia Cable Ab |
WIRE AND CABLE |
600 V |
68 A |
NO |
MIL |
6 mm2 |
COPPER |
STRANDED |
.003 ohm |
TIN |
NO |
HFI140 |
120 Cel |
SEAGUARD PRODUCT, DEFENCE, HABIATRON AND RAILGUARD |
-30 Cel |
4 mm |
1 |
FLAME RESISTANT, LOW SMOKE GENERATION, STANDARD: DEF STAN 61-12 PART 18 |
FLEXIBLE CORD AND FIXTURE WIRE |
84X0.300 |
|||||||||||||||||||
|
Tag-connect |
CABLE ASSEMBLY |
IDC |
TAG-CONNECT |
NO |
PLUG-OF-NAILS |
||||||||||||||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER ALLOY |
STRANDED |
.053 ohm |
TIN |
YES |
22 AWG |
ETFE |
150 Cel |
NO |
MIL-DTL-22759 |
NO |
-65 Cel |
22 |
1.09 mm |
1 |
STANDARD: MIL-DTL-22759 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
|||||||||||||||||
J S T Mfg |
CABLE ASSEMBLY |
SSHL-002T-P0.2 |
SSHL-002T-P0.2 |
50 V |
1 A |
NO |
UL |
.08 mm2 |
NO |
NO |
NO |
28 |
1 |
.213 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||||||||
J S T Mfg |
CABLE ASSEMBLY |
SSHL-002T-P0.2 |
SSHL-002T-P0.2 |
50 V |
1 A |
NO |
UL |
.08 mm2 |
NO |
NO |
NO |
28 |
1 |
.162 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||||||||
Tag-connect |
CABLE ASSEMBLY |
TAG6PIN |
IDC |
NO |
PLUG-OF-NAILS |
|||||||||||||||||||||||||||||||||||
JST |
CABLE ASSEMBLY |
SPHD-001T-P0.5 |
SPHD-001T-P0.5 |
250 V |
3 A |
NO |
UL |
NO |
NO |
NO |
22 |
.3048 mm |
||||||||||||||||||||||||||||
|
Cinch Connectivity Solutions |
WIRE AND CABLE |
750000 V |
NO |
STRANDED |
TEFLON |
YES |
NO |
NO |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||||||||
|
Bulgin |
CABLE ASSEMBLY |
USB B MALE |
USB A MALE |
30 V |
1 A |
NO |
UL |
.08 mm2 |
POLYVINYLCHLORIDE |
NO |
70 Cel |
NO |
NO |
0 Cel |
28 |
4 |
3 mm |
COMMUNICATION CABLE |
|||||||||||||||||||||
|
Carlisle Interconnect Technologies |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
.0495 ohm |
SILVER |
YES |
PTFE |
200 Cel |
SMOKE EMISSION, OVERLOAD STABILITY AND FLAMMABILITY |
-55 Cel |
22 |
1.3 mm |
1 |
STANDARD: MIL-W-22759/11 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
MIL-DTL-22759 |
.82 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
YES |
18 AWG |
CROSSLINKED ETHYLENE-TETRAFLUOROETHYLENE |
150 Cel |
NO |
MIL-DTL-22759 |
NO |
-65 Cel |
18 |
1.52 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X30 |
||||||||||||||||||
|
Carlisle Interconnect Technologies |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
.0301 ohm |
SILVER |
YES |
PTFE |
200 Cel |
NO |
SMOKE EMISSION, OVERLOAD STABILITY AND FLAMMABILITY |
NO |
-55 Cel |
20 |
1.52 mm |
1 |
STANDARD: MIL-W-22759/11 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||
Consolidated Electronic Wire & Cable |
WIRE AND CABLE |
300 V |
NO |
CM; CSA; UL |
.823 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYL CHLORIDE |
TIN |
NO |
POLYVINYL CHLORIDE |
80 Cel |
NO |
NO |
18 |
13.97 mm |
25 |
FLEXIBLE CORD AND FIXTURE WIRE |
16X30 |
|||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
SOCKET |
SOCKET |
NO |
UL |
.081 mm2 |
COPPER ALLOY |
TIN |
POLYVINYL CHLORIDE |
80 Cel |
-10 Cel |
28 |
40 |
.864 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; CUL; MSHA; UL |
2.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
888 ohm |
PVC/NYLON |
90 Cel |
INDUSTRIAL PLANT EXPANSIONS, AUTOMOTIVE PLANTS, TRAY WIRING |
-25 Cel |
14 |
16.2 mm |
12 |
VNTC CABLES |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||||
|
Tag Connect |
CABLE ASSEMBLY |
IDC |
TAG-CONNECT |
NO |
|||||||||||||||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER ALLOY |
STRANDED |
.032 ohm |
TIN |
YES |
20 AWG |
ETFE |
150 Cel |
NO |
MIL-DTL-22759 |
NO |
-65 Cel |
20 |
1.27 mm |
1 |
STANDARD: MIL-DTL-22759 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
|||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
300 V |
NO |
CE; EAC; VDE |
2.5 mm2 |
BARE COPPER |
STRANDED |
POLYMER |
NO |
POLYETHYLENE |
NO |
IN DRY, DAMP OR WET INTERIORS |
NO |
13 |
9.4 mm |
3 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||
|
Tag-connect |
CABLE ASSEMBLY |
IDC CONNECTOR |
10P TAG-CONNECT |
NO |
|||||||||||||||||||||||||||||||||||
Startech.com |
CABLE ASSEMBLY |
IDC |
USB A 2.0 FEMALE |
NO |
CE |
|||||||||||||||||||||||||||||||||||
Carlisle Interconnect Technologies |
WIRE AND CABLE |
250 V |
NO |
MIL |
COPPER |
STRANDED |
.126 ohm |
SILVER |
YES |
EXTRUDED PTFE |
200 Cel |
NO |
NO |
-55 Cel |
26 |
.84 mm |
1 |
STANDARD: MIL-W-16878 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||
Standard Wire & Cable |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
NYLON |
.02 ohm |
TIN |
YES |
POLYVINYLCHLORIDE |
105 Cel |
18 |
2.24 mm |
1 |
STANDARD: MIL-DTL-5086 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X30 |
||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
NO |
DIN; VDE |
NO |
60 Cel |
NO |
PATCHING, CROSSING, INDOOR CABLING |
NO |
-20 Cel |
13.5 mm |
36 |
COMMUNICATION CABLE |
||||||||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
CSA, CAA, MIL, UL |
COPPER ALLOY |
STRANDED |
.053 ohm |
TIN |
22 AWG |
150 Cel |
SPEC 55 |
-65 Cel |
22 |
1.09 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
||||||||||||||||||||||
|
Bulgin |
CABLE ASSEMBLY |
USB B MALE |
USB A MALE |
30 V |
1 A |
NO |
UL |
.08 mm2 |
POLYVINYLCHLORIDE |
NO |
70 Cel |
NO |
NO |
0 Cel |
28 |
4 |
2 mm |
COMMUNICATION CABLE |
|||||||||||||||||||||
|
Tag-connect |
CABLE ASSEMBLY |
TAG6PIN |
IDC |
NO |
PLUG-OF-NAILS |
||||||||||||||||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
NO |
.326 mm2 |
TINNED COPPER |
SOLID |
NO |
NO |
NO |
22 |
1 |
.003 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X22 |
||||||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
.38 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
22 AWG |
150 Cel |
GENERAL PURPOSE, LIGHTWEIGHT |
MIL-DTL-81044 |
-65 Cel |
22 |
1.19 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
||||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
SOCKET |
SOCKET |
2.3 A |
NO |
UL |
.051 mm2 |
STRANDED |
TIN |
POLYVINYL CHLORIDE |
105 Cel |
-40 Cel |
30 |
10 |
.064 mm |
FLAT CABLE |
7X38 |
||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE; DIN; EAC |
.75 mm2 |
BARE COPPER |
STRANDED |
POLYURETHANE |
NO |
THERMOPLASTIC ELASTOMER |
90 Cel |
YES |
ROBUST, FLEXIBLE CABLE FOR USE IN DRY, DAMP AND WET ROOMS |
NO |
-40 Cel |
19 |
8.1 mm |
5 |
STANDARDS: DIN VDE 0285-525-2-21; DIN EN 50525-2-21 |
COMMUNICATION AND CONTROL CABLE |
||||||||||||||||||||
FTDI |
CABLE ASSEMBLY |
USB |
UART |
5.25 V |
.015 A |
NO |
CE; FCC |
NO |
85 Cel |
NO |
RASPBERRY PI |
NO |
-40 Cel |
3 |
1 mm |
COMMUNICATION CABLE |
||||||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
PLUG |
PLUG |
425 V |
3 A |
NO |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-20 Cel |
28 |
14 |
.127 mm |
FLAT CABLE |
7X36 |
||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
2.5 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
14 |
3.8 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
320X0.1 |
||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
.62 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
20 AWG |
150 Cel |
GENERAL PURPOSE, LIGHTWEIGHT |
SPEC 44 |
-65 Cel |
20 |
1.4 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
.38 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
22 AWG |
150 Cel |
GENERAL PURPOSE, LIGHTWEIGHT |
SPEC 44 |
-65 Cel |
22 |
1.19 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
.518 mm2 |
COPPER ALLOY |
STRANDED |
.031 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-55 Cel |
20 |
1.52 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
.62 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
20 AWG |
150 Cel |
GENERAL PURPOSE, LIGHTWEIGHT |
SPEC 44 |
-65 Cel |
20 |
1.4 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE; DIN; EAC |
.75 mm2 |
BARE COPPER |
STRANDED |
POLYURETHANE |
NO |
THERMOPLASTIC ELASTOMER |
90 Cel |
YES |
ROBUST, FLEXIBLE CABLE FOR USE IN DRY, DAMP AND WET ROOMS |
NO |
-40 Cel |
19 |
8.1 mm |
5 |
STANDARDS: DIN VDE 0285-525-2-21; DIN EN 50525-2-21 |
COMMUNICATION AND CONTROL CABLE |
||||||||||||||||||||
|
Habia Cable Ab |
WIRE AND CABLE |
600 V |
101 A |
NO |
MIL |
10 mm2 |
COPPER |
STRANDED |
.002 ohm |
TIN |
NO |
HFI140 |
120 Cel |
SEAGUARD PRODUCT, DEFENCE, HABIATRON AND RAILGUARD |
-30 Cel |
5.1 mm |
1 |
FLAME RESISTANT, LOW SMOKE GENERATION, STANDARD: DEF STAN 61-12 PART 18 |
FLEXIBLE CORD AND FIXTURE WIRE |
80X0.400 |
Electrical wires and cables are conductive materials that are used to transmit electrical power and signals from one location to another. They are an essential component of any electrical system, ranging from small electronic devices to large industrial installations.
Electrical wires are typically made of a conductive material, such as copper or aluminum, that is coated in an insulating material to prevent electrical leakage or short-circuits. They are available in various gauges and thicknesses to handle different levels of electrical current and resistance.
Cables, on the other hand, are bundles of two or more electrical wires that are wrapped in an outer jacket for protection and insulation. They are designed for specific purposes, such as transmitting high-speed data, audio, or video signals, and can be shielded or unshielded to reduce electromagnetic interference.
Both electrical wires and cables are critical components of modern electrical systems and are used in a wide range of applications, including residential and commercial buildings, automotive and aerospace industries, telecommunications, and more.