Part | RoHS | Manufacturer | Connector Accessory Type | Connector Side-1 | Connector Side-2 | Rated Voltage | Rated Current | Shielding | Approvals (V) | Cross Section Area | Finish Thickness | Conductor Material | Construction | Minimum Wire Size | Jacket Material | Terminal Type | Resistance | Conductor Finish | MIL Conformity | Maximum Wire Size | Insulator Material | Maximum Operating Temperature | DIN Conformity | Application | Cable Types | IEC Conformity | Minimum Operating Temperature | Wire Gauge (AWG) | Design | Diameter | No. of Conductors | Mounting Style | Additional Features | Material | Mounting Option-2 | Length | Mounting Option-1 | Wire & Cable Name | Stranding | Rated DC Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
MIL |
2.081 mm2 |
COPPER ALLOY |
STRANDED |
.009 ohm |
TIN |
YES |
POLYVINYLCHLORIDE |
80 Cel |
NO |
NO |
-20 Cel |
14 |
4.17 mm |
1 |
STANDARD: MIL-W-76B |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
41X30 |
|||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
CUL; UL |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
POLYVINYL CHLORIDE |
105 Cel |
NO |
NO |
-20 Cel |
28 |
50 |
.508 mm |
FLAT CABLE |
7X36 |
||||||||||||||||||||
|
Volex Plc |
CABLE ASSEMBLY |
NEMA5-15P |
IEC 60320 C13 |
125 V |
10 A |
NO |
CSA; CUL; UL |
POLYVINYL CHLORIDE |
60 Cel |
8 mm |
POWER CABLE |
||||||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
NO |
CEC; CUL; NEC; UL |
.205 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYL CHLORIDE |
.09 ohm |
NO |
POLYOLEFIN |
75 Cel |
NO |
GIGABIT ETHERNET, 100BASETX, DIGITAL VIDEO |
NO |
-20 Cel |
24 |
5.588 mm |
8 |
304.8 mm |
COMMUNICATION CABLE |
7X32 |
|||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
NO |
UL |
COPPER |
SOLID |
.341 ohm |
SILVER |
NO |
ETHYLENE-TETRAFLUOROETHYLENE COPOLYMER |
150 Cel |
NO |
NO |
-70 Cel |
30 |
.51 mm |
1 |
30.5 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X1 |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
NO |
UL |
COPPER |
SOLID |
SILVER |
ETHYLENE-TETRAFLUOROETHYLENE COPOLYMER |
150 Cel |
-70 Cel |
24 |
.76 mm |
1 |
30.5 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
.205 mm2 |
COPPER ALLOY |
STRANDED |
.082 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-55 Cel |
24 |
1.12 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X32 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
.205 mm2 |
COPPER ALLOY |
STRANDED |
.082 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-55 Cel |
24 |
1.12 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X32 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
MIL-W-76B; MIL-W-16878E/1 |
.326 mm2 |
COPPER ALLOY |
STRANDED |
.053 ohm |
TIN |
YES |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-55 Cel |
22 |
1.27 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
||||||||||||||||||
|
Amphenol |
WIRE AND CABLE |
300 V |
1 A |
NO |
CSA, UL |
TINNED COPPER |
POLYVINYL CHLORIDE |
105 Cel |
28 |
64 |
FLAT RIBBON CABLE |
7X36 |
|||||||||||||||||||||||||||
Amphenol |
WIRE AND CABLE |
1.3 A |
NO |
CSA; UL |
TINNED COPPER |
.213 ohm |
POLYVINYL CHLORIDE |
105 Cel |
28 |
7 |
PLANAR CABLE |
7X36 |
||||||||||||||||||||||||||||
|
Aries Electronics |
WIRE AND CABLE |
300 V |
3 A |
NO |
UL |
.129 mm2 |
COPPER |
SOLID |
NO |
105 Cel |
NO |
NO |
-55 Cel |
26 |
20 |
.076 mm |
FLAT CABLE |
||||||||||||||||||||||
|
TE Connectivity |
MALE-ON-WIRE |
MALE-ON-WIRE |
NO |
159.88 mm2 |
28 AWG |
28 |
.075 mm |
COMMUNICATION CABLE |
|||||||||||||||||||||||||||||||
|
Molex |
CABLE ASSEMBLY |
MICRO-FIT 3.0 |
MICRO-FIT 3.0 |
300 V |
NO |
UL |
POWER |
20 |
5.5 mm |
MICRO-FIT 3.0 |
|||||||||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE; DIN; EAC; VDE |
1.5 mm2 |
BARE COPPER |
STRANDED |
NO |
80 Cel |
YES |
CABLE FOR MACHINE ,EQUIPMENT AND APPLIANCES |
NO |
-40 Cel |
16 |
26.3 mm |
37 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
UL |
.963 mm2 |
COPPER ALLOY |
STRANDED |
NICKEL |
NO |
POLYTETRAFLUOROETHYLENE |
300 Cel |
NO |
NO |
-150 Cel |
18 |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X30 |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
250 V |
NO |
.081 mm2 |
COPPER ALLOY |
STRANDED |
.19 ohm |
SILVER |
POLYTETRAFLUOROETHYLENE |
200 Cel |
-60 Cel |
28 |
.69 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X40 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
250 V |
NO |
.205 mm2 |
COPPER ALLOY |
STRANDED |
.073 ohm |
SILVER |
POLYTETRAFLUOROETHYLENE |
200 Cel |
-60 Cel |
24 |
.91 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X36 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
NO |
3.31 mm2 |
COPPER ALLOY |
SOLID |
.005 ohm |
TIN |
NO |
200 Cel |
NO |
NO |
0 Cel |
12 |
2.057 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
NO |
.081 mm2 |
COPPER ALLOY |
SOLID |
.226 ohm |
TIN |
NO |
150 Cel |
NO |
ELECTRICAL WIRING INDUSTRY |
NO |
0 Cel |
28 |
.33 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X28 |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
NO |
.0509 mm2 |
COPPER ALLOY |
SOLID |
.364 ohm |
TIN |
NO |
150 Cel |
NO |
NO |
0 Cel |
30 |
.254 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1 |
|||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE; DIN VDE 0285-525-3-11; DIN EN 50525-3-11 |
.75 mm2 |
BARE COPPER |
STRANDED |
POLYETHYLENE |
NO |
POLYETHYLENE |
70 Cel |
YES |
COOKING AND HEATING APPARATUS |
YES |
-40 Cel |
19 |
6.3 mm |
2 |
CONTROL CABLE |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.051 mm2 |
COPPER ALLOY |
STRANDED |
.331 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
30 |
1.12 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X38 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.051 mm2 |
COPPER ALLOY |
STRANDED |
.331 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
30 |
1.12 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X38 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.129 mm2 |
COPPER ALLOY |
STRANDED |
.135 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
26 |
1.3 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X34 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.326 mm2 |
COPPER ALLOY |
STRANDED |
.053 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
22 |
1.57 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.518 mm2 |
COPPER ALLOY |
SOLID |
.034 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
20 |
1.63 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X20 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.518 mm2 |
COPPER ALLOY |
SOLID |
.034 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
20 |
1.63 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X20 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
TINNED COPPER |
STRANDED |
.023 ohm |
NO |
PVC |
105 Cel |
NO |
NO |
-40 Cel |
18 |
2.01 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
16X30 |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
1.309 mm2 |
COPPER ALLOY |
STRANDED |
.014 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
16 |
3.15 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
26X30 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
2.081 mm2 |
COPPER ALLOY |
STRANDED |
.009 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
14 |
3.51 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
41X30 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
250 V |
NO |
MIL-W-16878/6; UL |
.032 mm2 |
COPPER ALLOY |
SOLID |
.531 ohm |
SILVER |
YES |
POLYTETRAFLUOROETHYLENE |
200 Cel |
NO |
NO |
-60 Cel |
32 |
.483 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X32 |
||||||||||||||||||
|
3m Electronic Products Division |
CABLE ASSEMBLY |
300 V |
NO |
CUL, UL |
STRANDED |
TIN |
28 |
7 |
30.48 mm |
FLAT FLEXIBLE CABLE |
|||||||||||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
UL |
TINNED COPPER |
STRANDED |
TIN |
POLYVINYL CHLORIDE |
105 Cel |
-20 Cel |
28 |
9 |
3M |
11.43 mm |
FLAT FLEXIBLE CABLE |
7X36 |
|||||||||||||||||||||||
|
3m Electronic Products Division |
CABLE ASSEMBLY |
300 V |
NO |
CUL, UL |
STRANDED |
TIN |
28 |
7 |
30.48 mm |
FLAT FLEXIBLE CABLE |
|||||||||||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
UL |
.129 mm2 |
COPPER |
STRANDED |
TIN |
NO |
THERMOPLASTIC ELASTOMER |
105 Cel |
NO |
NO |
-40 Cel |
26 |
37 |
30.48 mm |
FLAT CABLE |
7 |
||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
REDUCED CROSSTALK IN BALANCED DRIVE |
-20 Cel |
28 |
10 |
30.48 mm |
FLAT CABLE |
7X36 |
||||||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
CUL; UL |
.129 mm2 |
COPPER |
STRANDED |
TIN |
NO |
POLYVINYL CHLORIDE |
105 Cel |
NO |
HIGH POWER AND FLEXIBLE APPLICATION |
NO |
-20 Cel |
26 |
16 |
30.48 mm |
FLAT CABLE |
7X34 |
|||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
CUL; UL |
.129 mm2 |
COPPER |
STRANDED |
TIN |
NO |
POLYVINYL CHLORIDE |
105 Cel |
NO |
HIGH POWER AND FLEXIBLE APPLICATION |
NO |
-20 Cel |
26 |
44 |
30.48 mm |
FLAT CABLE |
7X34 |
|||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
10000 V |
NO |
UL |
5.261 mm2 |
COPPER ALLOY |
STRANDED |
.004 ohm |
TIN |
NO |
SILICONE RUBBER |
150 Cel |
NO |
NO |
-40 Cel |
10 |
5.03 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
105X30 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
10000 V |
NO |
5.261 mm2 |
COPPER ALLOY |
STRANDED |
.004 ohm |
TIN |
SILICONE RUBBER |
150 Cel |
-40 Cel |
10 |
5.03 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
105X30 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
10000 V |
NO |
2.081 mm2 |
COPPER ALLOY |
STRANDED |
.009 ohm |
TIN |
SILICONE RUBBER |
150 Cel |
-40 Cel |
14 |
3.91 mm |
1 |
152.4 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
41X30 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
2.081 mm2 |
COPPER ALLOY |
STRANDED |
.009 ohm |
TIN |
SILICONE RUBBER |
150 Cel |
-40 Cel |
14 |
4.27 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
41X30 |
||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; HAR; UL |
2.5 mm2 |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
105 Cel |
CABLING |
-40 Cel |
14 |
4 mm |
OIL RESISTANT, FLAME RESISTANT |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.518 mm2 |
COPPER ALLOY |
STRANDED |
.037 ohm |
TIN |
POLYVINYLCHLORIDE |
80 Cel |
-10 Cel |
20 |
1.45 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
10X30 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.129 mm2 |
COPPER ALLOY |
SOLID |
.144 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
80 Cel |
NO |
NO |
-10 Cel |
26 |
.91 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X26 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.129 mm2 |
COPPER ALLOY |
SOLID |
.144 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
80 Cel |
NO |
NO |
-10 Cel |
26 |
.914 mm |
1 |
1524 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.129 mm2 |
COPPER ALLOY |
SOLID |
.144 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
80 Cel |
NO |
NO |
-10 Cel |
26 |
.914 mm |
1 |
1524 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1 |
Electrical wires and cables are conductive materials that are used to transmit electrical power and signals from one location to another. They are an essential component of any electrical system, ranging from small electronic devices to large industrial installations.
Electrical wires are typically made of a conductive material, such as copper or aluminum, that is coated in an insulating material to prevent electrical leakage or short-circuits. They are available in various gauges and thicknesses to handle different levels of electrical current and resistance.
Cables, on the other hand, are bundles of two or more electrical wires that are wrapped in an outer jacket for protection and insulation. They are designed for specific purposes, such as transmitting high-speed data, audio, or video signals, and can be shielded or unshielded to reduce electromagnetic interference.
Both electrical wires and cables are critical components of modern electrical systems and are used in a wide range of applications, including residential and commercial buildings, automotive and aerospace industries, telecommunications, and more.