Part | RoHS | Manufacturer | Fiber Optic Type | Mounting Feature | Maximum Supply Voltage | Terminal Finish | Maximum Operating Temperature | Minimum Operating Temperature | Emitter or Detector Type | Responsivity | Fiber Type | Connection Type | Nominal Supply Voltage | Packing Method | Body Length/Diameter | Body Width | Package Style (Meter) | Reception Type | Sub-Category | Body Height | Nominal Operating Wavelength | Minimum Supply Voltage | Minimum Operating Wavelength | Communication Standard | Maximum Operating Wavelength | Data Rate | Minimum Return Loss | Additional Features | JESD-609 Code | Built-in Features | Sensitivity Level |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
TIN |
85 Cel |
-40 Cel |
PHOTODIODE |
PCS, POF |
3.3 V |
DIGITAL |
Fiber Optic Receivers |
658 nm |
3.135 V |
630 nm |
RS-232, RS-485 |
685 nm |
IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 VOLTS |
e3 |
AMPLIFIER |
|||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
TIN |
85 Cel |
-40 Cel |
LED |
POF |
3.3 V |
DIGITAL |
Fiber Optic Receivers |
658 nm |
3.135 V |
RS-232, RS-485 |
ITSS ALSO OPERATES IN 4.75 TO 5.25 V SUPPLY VOLTAGE |
e3 |
||||||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
Tin (Sn) |
95 Cel |
-40 Cel |
PHOTODIODE |
PCS, POF |
3.3 V |
ANALOG |
7.6 mm |
3.135 V |
IT ALSO HAS NOM-SUPPLY VOLTAGE 5V AND DATA RATE 10 MBD |
e3 |
AMPLIFIER |
|||||||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
Tin (Sn) |
95 Cel |
-40 Cel |
POF |
3.3 V |
DIGITAL |
Fiber Optic Receivers |
650 nm |
3.135 V |
IT ALSO OPERATES AT 5V NOMINAL SUPPLY VOLTAGE |
e3 |
PHOTODIODE |
|||||||||||||||
Glenair |
RECEIVER |
3.465 V |
85 Cel |
-40 Cel |
PIN PHOTODIODE |
50/125, 62.5/125, MMF |
3.3 V |
845 nm |
3.135 V |
830 nm |
GBE |
860 nm |
1250 Mbps |
AMPLIFIER, QUANTIZER |
-17 dBm |
||||||||||||||||
|
Infineon Technologies |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
95 Cel |
-40 Cel |
PIN PHOTODIODE |
POF |
3.3 V |
9.7 mm |
5.6 inch |
DIGITAL |
7.89 mm |
650 nm |
3.135 V |
630 nm |
685 nm |
25 Mbps |
OTHER VALUE FOR SUPPLY VOLTAGE FROM 4.75VDC TO 5.25VDC |
-25 dBm |
|||||||||||
Renesas Electronics |
RECEIVER |
SURFACE MOUNT |
3.465 V |
85 Cel |
-40 Cel |
Fiber Optic Receivers |
|||||||||||||||||||||||||
Renesas Electronics |
RECEIVER |
SURFACE MOUNT |
3.465 V |
85 Cel |
-40 Cel |
Fiber Optic Receivers |
|||||||||||||||||||||||||
Renesas Electronics |
RECEIVER |
SURFACE MOUNT |
3.465 V |
75 Cel |
0 Cel |
Fiber Optic Receivers |
|||||||||||||||||||||||||
Renesas Electronics |
RECEIVER |
SURFACE MOUNT |
3.465 V |
75 Cel |
0 Cel |
Fiber Optic Receivers |
|||||||||||||||||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
95 Cel |
-40 Cel |
PHOTODIODE |
POF |
3.3 V |
2.72 inch |
DIGITAL |
Fiber Optic Receivers |
650 nm |
3.135 V |
635 nm |
675 nm |
150 Mbps |
AMPLIFIER |
|||||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
95 Cel |
-40 Cel |
Fiber Optic Receivers |
650 nm |
|||||||||||||||||||||||
|
Broadcom |
RECEIVER |
BOARD/PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
34.12 mm |
17.5 inch |
DIGITAL |
Fiber Optic Receivers |
12.9 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2500 Mbps |
12 dB |
10 X 10 ARRYA |
AMPLIFIER |
-11.8 dBm |
||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
95 Cel |
-40 Cel |
3.3 V |
DIGITAL |
Fiber Optic Receivers |
650 nm |
3.135 V |
630 nm |
685 nm |
IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 VOLTS |
-25 dBm |
||||||||||||||||
|
Broadcom |
RECEIVER |
BOARD/PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
34.12 mm |
17.5 inch |
DIGITAL |
Fiber Optic Receivers |
13.12 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2500 Mbps |
12 dB |
10 X 10 ARRYA |
AMPLIFIER |
-11.8 dBm |
||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
95 Cel |
-40 Cel |
PIN PHOTODIODE |
POF |
3.3 V |
9.6 mm |
3.4 inch |
DIGITAL |
Fiber Optic Receivers |
6.2 mm |
650 nm |
3.135 V |
630 nm |
685 nm |
25 Mbps |
IT ALSO OPERATES VOLTAGE RANGES FROM 4.75V TO 5.25V |
-25 dBm |
||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
95 Cel |
-40 Cel |
3.3 V |
2.72 inch |
DIGITAL |
Fiber Optic Receivers |
650 nm |
3.135 V |
630 nm |
685 nm |
IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 VOLTS |
-25 dBm |
|||||||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
95 Cel |
-40 Cel |
PIN PHOTODIODE |
POF |
3.3 V |
9.6 mm |
3.4 inch |
DIGITAL |
Fiber Optic Receivers |
6.2 mm |
650 nm |
3.135 V |
630 nm |
685 nm |
25 Mbps |
IT ALSO OPERATES VOLTAGE RANGES FROM 4.75V TO 5.25V |
-25 dBm |
||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
Tin (Sn) |
95 Cel |
-40 Cel |
POF |
3.3 V |
DIGITAL |
Fiber Optic Receivers |
650 nm |
3.135 V |
IT ALSO OPERATES AT 5V NOMINAL SUPPLY VOLTAGE |
e3 |
PHOTODIODE |
|||||||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
95 Cel |
-40 Cel |
3.3 V |
8.98 mm |
2.72 inch |
DIGITAL |
Fiber Optic Receivers |
650 nm |
3.135 V |
630 nm |
685 nm |
IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 VOLT |
-25 dBm |
||||||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
95 Cel |
-40 Cel |
3.3 V |
DIGITAL |
Fiber Optic Receivers |
650 nm |
3.135 V |
630 nm |
685 nm |
IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 VOLTS |
-25 dBm |
||||||||||||||||
|
Broadcom |
RECEIVER |
3.465 V |
85 Cel |
0 Cel |
PIN PHOTODIODE |
SMF |
FC CONNECTOR |
TO-46 |
ANALOG |
Fiber Optic Receivers |
1310 nm |
850 nm |
1600 nm |
IT ALSO HAS NOM-WAVELENGTH 1550 NM |
AMPLIFIER |
|||||||||||||||
|
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
95 Cel |
-40 Cel |
3.3 V |
8.98 mm |
2.72 inch |
DIGITAL |
Fiber Optic Receivers |
650 nm |
3.135 V |
630 nm |
685 nm |
IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 VOLT |
-25 dBm |
||||||||||||||
|
Broadcom |
RECEIVER |
BOARD/PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
DIGITAL |
Fiber Optic Receivers |
850 nm |
3.135 V |
830 nm |
860 nm |
2500 Mbps |
12 dB |
10 X 10 ARRYA |
AMPLIFIER |
-11.8 dBm |
|||||||||||
|
Broadcom |
RECEIVER |
BOARD/PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
34.12 mm |
17.5 inch |
DIGITAL |
Fiber Optic Receivers |
7.56 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2720 Mbps |
12 dB |
10 X 10 ARRYA |
AMPLIFIER |
-15.5 dBm |
||||||||
|
Broadcom |
RECEIVER |
PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
41.47 mm |
17.5 inch |
DIGITAL |
Fiber Optic Receivers |
16 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2700 Mbps |
19 dB |
10X10 ARRAY |
AMPLIFIER |
-15.5 dBm |
||||||||
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
62.5/125, MMF |
3.3 V |
41.07 mm |
17.6 inch |
DIGITAL |
Fiber Optic Receivers |
16 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2700 Mbps |
19 dB |
10X10 ARRAY |
AMPLIFIER |
-18.5 dBm |
|||||||||
|
Broadcom |
RECEIVER |
BOARD/PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
62.5/125, MMF |
3.3 V |
DIGITAL |
Fiber Optic Receivers |
850 nm |
3.135 V |
830 nm |
860 nm |
2720 Mbps |
12 dB |
10 X 10 ARRAY |
AMPLIFIER |
-15.5 dBm |
|||||||||||
|
Broadcom |
RECEIVER |
BOARD/PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
34.12 mm |
DIGITAL |
Fiber Optic Receivers |
7.56 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2720 Mbps |
12 dB |
10 X 10 ARRYA |
AMPLIFIER |
-15.5 dBm |
|||||||||
|
Broadcom |
RECEIVER |
PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
34.12 mm |
17.5 inch |
DIGITAL |
Fiber Optic Receivers |
16 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2700 Mbps |
19 dB |
10X10 ARRAY |
AMPLIFIER |
-15.5 dBm |
||||||||
Broadcom |
RECEIVER |
THROUGH HOLE MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
62.5/125, MMF |
3.3 V |
41.07 mm |
17.6 inch |
DIGITAL |
Fiber Optic Receivers |
16 mm |
850 nm |
830 nm |
860 nm |
2700 Mbps |
19 dB |
AMPLIFIER |
-18.5 dBm |
|||||||||||
|
Broadcom |
RECEIVER |
BOARD/PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
62.5/125, MMF |
3.3 V |
41.07 mm |
17.6 inch |
DIGITAL |
Fiber Optic Receivers |
12.9 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2720 Mbps |
12 dB |
10 X 10 ARRAY |
AMPLIFIER |
-15.5 dBm |
||||||||
|
Broadcom |
RECEIVER |
BOARD/PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
62.5/125, MMF |
3.3 V |
41.37 mm |
17.6 inch |
DIGITAL |
Fiber Optic Receivers |
13.1 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2720 Mbps |
12 dB |
10 X 10 ARRAY |
AMPLIFIER |
-15.5 dBm |
||||||||
|
Broadcom |
RECEIVER |
PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
34.12 mm |
17.5 inch |
DIGITAL |
Fiber Optic Receivers |
12.9 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2700 Mbps |
19 dB |
10X10 ARRAY |
AMPLIFIER |
-15.5 dBm |
||||||||
|
Broadcom |
RECEIVER |
BOARD/PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
34.12 mm |
17.5 inch |
DIGITAL |
Fiber Optic Receivers |
13.2 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2720 Mbps |
12 dB |
10 X 10 ARRYA |
AMPLIFIER |
-15.5 dBm |
||||||||
|
Broadcom |
RECEIVER |
PANEL MOUNT |
3.465 V |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
DIGITAL |
3.135 V |
830 nm |
860 nm |
2.7 Mbps |
19 dB |
AMPLIFIER |
-18.5 dBm |
||||||||||||||||
|
Broadcom |
RECEIVER |
BOARD/PANEL MOUNT |
3.465 V |
80 Cel |
0 Cel |
PIN PHOTODIODE |
50/125, MMF |
3.3 V |
34.12 mm |
17.5 inch |
DIGITAL |
Fiber Optic Receivers |
12.9 mm |
850 nm |
3.135 V |
830 nm |
860 nm |
2720 Mbps |
12 dB |
10 X 10 ARRYA |
AMPLIFIER |
-15.5 dBm |
Fiber optic receivers are electronic devices that are used in fiber optic communication systems to detect and convert optical signals into electrical signals. They are a critical component of fiber optic networks, enabling high-speed data transmission and processing over long distances.
Fiber optic receivers typically consist of a photodetector, an amplifier, and a demodulator. The photodetector detects the optical signal and converts it into an electrical signal. The amplifier amplifies the electrical signal, making it strong enough for further processing. The demodulator extracts the data from the electrical signal, enabling it to be decoded and processed by the receiving device.
There are different types of photodetectors used in fiber optic receivers, including PIN photodiodes, avalanche photodiodes, and photomultiplier tubes. These photodetectors convert the incoming optical signal into an electrical current, which is then amplified and demodulated.
Fiber optic receivers come in different configurations and designs, depending on the application and the required performance. They can be integrated into a fiber optic network or mounted in a separate enclosure, depending on the application and the space available.