8 Logic Gates 2,400+

Reset All
Part RoHS Manufacturer Logic IC Type Temperature Grade Terminal Form No. of Terminals Package Code Package Shape Total Dose (V) Package Body Material Schmitt Trigger Surface Mount No. of Functions Technology Screening Level No. of Inputs No. of Bits Translation Packing Method Nominal Supply Voltage / Vsup (V) Power Supplies (V) Load Capacitance (CL) Package Style (Meter) Package Equivalence Code Propagation Delay (tpd) Maximum I (ol) Sub-Category Terminal Pitch Maximum Operating Temperature Output Characteristics Minimum Operating Temperature Terminal Finish Terminal Position Control Type Minimum fmax JESD-30 Code Moisture Sensitivity Level (MSL) Maximum Supply Voltage (Vsup) Maximum Seated Height Width Qualification Output Polarity Minimum Supply Voltage (Vsup) Maximum Power Supply Current (ICC) Additional Features JESD-609 Code Maximum Time At Peak Reflow Temperature (s) Peak Reflow Temperature (C) Length Family

SN74AUP2G02DCUR

Texas Instruments

NOR GATE

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.2

1.2/3.3

30 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

25.5 ns

4 Amp

Gates

.5 mm

85 Cel

-40 Cel

Nickel/Palladium/Gold (Ni/Pd/Au)

DUAL

R-PDSO-G8

1

3.6 V

.9 mm

2 mm

Not Qualified

.8 V

.0009 mA

e4

NOT SPECIFIED

260

2.3 mm

AUP/ULP/V

SN74LVC2G04DCTR

Texas Instruments

INVERTER

INDUSTRIAL

GULL WING

8

LSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

3

CMOS

1

1.8

SMALL OUTLINE, LOW PROFILE, SHRINK PITCH

.65 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

1.3 mm

2.8 mm

Not Qualified

1.65 V

2.95 mm

LVC/LCX/Z

SN74AUC2G02YEPR

Texas Instruments

NOR GATE

INDUSTRIAL

BALL

8

VFBGA

RECTANGULAR

UNSPECIFIED

NO

YES

2

CMOS

2

TR

1.2

1.2/2.5

15 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA8,2X4,20

3.5 ns

5 Amp

Gates

.5 mm

85 Cel

3-STATE

-40 Cel

BOTTOM

R-XBGA-B8

2.7 V

.5 mm

.9 mm

Not Qualified

.8 V

NOT SPECIFIED

NOT SPECIFIED

1.9 mm

AUC

SN74LVC2G02YZPR

Texas Instruments

NOR GATE

AUTOMOTIVE

BALL

8

VFBGA

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.8

3.3

50 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA8,2X4,20

8.9 ns

32 Amp

Gates

.5 mm

125 Cel

3-STATE

-40 Cel

Tin/Silver/Copper (Sn/Ag/Cu)

BOTTOM

R-PBGA-B8

1

5.5 V

.5 mm

.9 mm

Not Qualified

1.65 V

.01 mA

e1

NOT SPECIFIED

260

1.9 mm

LVC/LCX/Z

74LVC2G132DCUTG4

Texas Instruments

NAND GATE

AUTOMOTIVE

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

YES

2

CMOS

2

1.8

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

17 ns

32 Amp

.5 mm

125 Cel

-40 Cel

Nickel/Palladium/Gold (Ni/Pd/Au)

DUAL

R-PDSO-G8

1

5.5 V

.9 mm

2 mm

1.65 V

e4

NOT SPECIFIED

260

2.3 mm

LVC/LCX/Z

SN74LVC2G00YZPR

Texas Instruments

NAND GATE

AUTOMOTIVE

BALL

8

VFBGA

RECTANGULAR

UNSPECIFIED

NO

YES

2

CMOS

2

TR

1.8

3.3

50 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA8,2X4,20

8.6 ns

32 Amp

Gates

.5 mm

125 Cel

3-STATE

-40 Cel

Tin/Silver/Copper (Sn/Ag/Cu)

BOTTOM

R-XBGA-B8

1

5.5 V

.5 mm

.9 mm

Not Qualified

1.65 V

.01 mA

e1

NOT SPECIFIED

260

1.9 mm

LVC/LCX/Z

SN74LVC2G02DCUTG4

Texas Instruments

NOR GATE

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.8

3.3

50 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

8.9 ns

24 Amp

Gates

.5 mm

85 Cel

3-STATE

-40 Cel

NICKEL PALLADIUM GOLD

DUAL

R-PDSO-G8

1

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

e4

30

260

2.3 mm

LVC/LCX/Z

CD40107BH

Texas Instruments

NAND GATE

MILITARY

NO LEAD

8

DIE

RECTANGULAR

UNSPECIFIED

YES

2

CMOS

2

5

UNCASED CHIP

200 ns

125 Cel

OPEN-DRAIN

-55 Cel

UPPER

R-XUUC-N8

18 V

Not Qualified

3 V

4000/14000/40000

SN74LVC2GU04DCT

Texas Instruments

INVERTER

INDUSTRIAL

GULL WING

8

LSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

3

CMOS

1

1.8

SMALL OUTLINE, LOW PROFILE, SHRINK PITCH

.65 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

1.3 mm

2.8 mm

Not Qualified

1.65 V

2.95 mm

LVC/LCX/Z

SN74LVC2G02DCT

Texas Instruments

NOR GATE

INDUSTRIAL

GULL WING

8

LSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

2

CMOS

2

1.8

SMALL OUTLINE, LOW PROFILE, SHRINK PITCH

8.9 ns

.65 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

1.3 mm

2.8 mm

Not Qualified

1.65 V

2.95 mm

LVC/LCX/Z

SN74LVC2G32IDCTREP

Texas Instruments

OR GATE

INDUSTRIAL

GULL WING

8

SSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

5

3.3

50 pF

SMALL OUTLINE, SHRINK PITCH

SSOP8,.16

8 ns

24 Amp

Gates

.635 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

Not Qualified

1.65 V

SN7400PS

Texas Instruments

NAND GATE

COMMERCIAL

GULL WING

8

SOP

RECTANGULAR

PLASTIC/EPOXY

YES

2

TTL

2

5

SMALL OUTLINE

22 ns

1.27 mm

70 Cel

0 Cel

DUAL

R-PDSO-G8

5.25 V

2 mm

5.3 mm

4.75 V

6.2 mm

TTL/H/L

SN74LVC1404YZPR

Texas Instruments

INVERTER/BUFFER

INDUSTRIAL

BALL

8

VFBGA

RECTANGULAR

UNSPECIFIED

YES

YES

2

CMOS

1

TR

1.8

50 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

25.7 ns

32 Amp

.5 mm

85 Cel

-40 Cel

Tin/Silver/Copper (Sn/Ag/Cu)

BOTTOM

R-XBGA-B8

1

5.5 V

.5 mm

.9 mm

Not Qualified

1.65 V

.01 mA

e1

NOT SPECIFIED

260

1.9 mm

LVC/LCX/Z

SN74AUC2G00DCURE4

Texas Instruments

NAND GATE

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.2

1.2/2.5

15 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

2.5 ns

5 Amp

Gates

.5 mm

85 Cel

3-STATE

-40 Cel

NICKEL PALLADIUM GOLD

DUAL

R-PDSO-G8

1

2.7 V

.9 mm

2 mm

Not Qualified

.8 V

e4

30

260

2.3 mm

AUC

SN74LVC3G07MDCUREP

Texas Instruments

BUFFER

MILITARY

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

3

CMOS

1

TR

1.8

3.3

50 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

.5 ns

32 Amp

Gates

.5 mm

125 Cel

OPEN-DRAIN

-55 Cel

Nickel/Palladium/Gold (Ni/Pd/Au)

DUAL

R-PDSO-G8

1

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

.01 mA

e4

NOT SPECIFIED

260

2.3 mm

LVC/LCX/Z

SN54ALS8003JG

Texas Instruments

NAND GATE

MILITARY

THROUGH-HOLE

8

DIP

RECTANGULAR

CERAMIC, GLASS-SEALED

NO

NO

2

TTL

2

5

5

50 pF

IN-LINE

DIP8,.3

10 ns

Gates

2.54 mm

125 Cel

-55 Cel

DUAL

R-GDIP-T8

5.5 V

Not Qualified

4.5 V

1.5 mA

NOT SPECIFIED

NOT SPECIFIED

ALS

SN74LVC2G08YZAR

Texas Instruments

AND GATE

INDUSTRIAL

BALL

8

VFBGA

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.8

3.3

50 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA8,2X4,20

9 ns

24 Amp

Gates

.5 mm

85 Cel

-40 Cel

TIN SILVER COPPER

BOTTOM

R-PBGA-B8

1

5.5 V

.5 mm

.9 mm

Not Qualified

1.65 V

e1

1.9 mm

LVC/LCX/Z

SN74LVC2G32DCU

Texas Instruments

OR GATE

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

2

CMOS

2

1.8

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

8 ns

.5 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

2.3 mm

LVC/LCX/Z

SN74LVC3G34YZAR

Texas Instruments

BUFFER

INDUSTRIAL

BALL

8

VFBGA

RECTANGULAR

UNSPECIFIED

NO

YES

3

CMOS

1

TR

1.8

3.3

50 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA6,2X3,20

7.9 ns

24 Amp

Gates

.5 mm

85 Cel

-40 Cel

BOTTOM

R-XBGA-B8

5.5 V

.5 mm

.9 mm

Not Qualified

1.65 V

NOT SPECIFIED

NOT SPECIFIED

1.9 mm

LVC/LCX/Z

SN74LVC2GU04DCUR

Texas Instruments

INVERTER

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

3

CMOS

1

TR

1.8

3.3

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

24 Amp

Gates

.5 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

NOT SPECIFIED

NOT SPECIFIED

2.3 mm

LVC/LCX/Z

SN74LVC3G04YZAR

Texas Instruments

INVERTER

INDUSTRIAL

BALL

8

VFBGA

RECTANGULAR

UNSPECIFIED

NO

YES

3

CMOS

1

TR

1.8

3.3

50 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA8,2X4,20

7.9 ns

24 Amp

Gates

.5 mm

85 Cel

-40 Cel

TIN SILVER COPPER

BOTTOM

R-XBGA-B8

1

5.5 V

.5 mm

.9 mm

Not Qualified

1.65 V

e1

1.9 mm

LVC/LCX/Z

SN74AHC2G32HDCT3

Texas Instruments

OR GATE

INDUSTRIAL

GULL WING

8

SOP

RECTANGULAR

PLASTIC/EPOXY

YES

2

CMOS

2

5

SMALL OUTLINE

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

2 V

AHC/VHC/H/U/V

SN74AHC2G02HDCU3

Texas Instruments

NOR GATE

INDUSTRIAL

GULL WING

8

SOP

RECTANGULAR

PLASTIC/EPOXY

YES

2

CMOS

2

5

SMALL OUTLINE

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

2 V

AHC/VHC/H/U/V

SN74HCU7204PWR

Texas Instruments

INVERTER

INDUSTRIAL

GULL WING

8

TSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

1

TR

5

2/6

50 pF

SMALL OUTLINE, THIN PROFILE, SHRINK PITCH

TSSOP8,.25

100 ns

.02 Amp

Gates

.65 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

6 V

1.2 mm

3 mm

Not Qualified

2 V

NOT SPECIFIED

NOT SPECIFIED

4.4 mm

HC/UH

SN74LVC2G06DCUR

Texas Instruments

INVERTER

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

2

CMOS

1

1.8

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

.5 mm

85 Cel

OPEN-DRAIN

-40 Cel

DUAL

R-PDSO-G8

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

2.3 mm

LVC/LCX/Z

SN74AUC2G02DCTRG4

Texas Instruments

NOR GATE

INDUSTRIAL

GULL WING

8

LSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

2

CMOS

2

1.2

SMALL OUTLINE, LOW PROFILE, SHRINK PITCH

3.5 ns

.65 mm

85 Cel

-40 Cel

NICKEL PALLADIUM GOLD

DUAL

R-PDSO-G8

1

2.7 V

1.3 mm

2.8 mm

Not Qualified

.8 V

e4

30

260

2.95 mm

AUC

SN74LVC3G06YEPR

Texas Instruments

INVERTER

INDUSTRIAL

BALL

8

VFBGA

RECTANGULAR

UNSPECIFIED

NO

YES

3

CMOS

1

TR

1.8

3.3

50 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA8,2X4,20

7.2 ns

24 Amp

Gates

.5 mm

85 Cel

OPEN-DRAIN

-40 Cel

BOTTOM

R-XBGA-B8

5.5 V

.5 mm

.9 mm

Not Qualified

1.65 V

NOT SPECIFIED

NOT SPECIFIED

1.9 mm

LVC/LCX/Z

SNJ54S8003J

Texas Instruments

NAND GATE

MILITARY

THROUGH-HOLE

8

DIP

RECTANGULAR

CERAMIC

NO

NO

TTL

38535Q/M;38534H;883B

5

5

IN-LINE

DIP8,.3

20 Amp

Gates

2.54 mm

125 Cel

-55 Cel

DUAL

R-XDIP-T8

Not Qualified

20 mA

SN74LVC2G32MDCUREP

Texas Instruments

OR GATE

MILITARY

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.8

3.3

50 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

11 ns

32 Amp

Gates

.5 mm

125 Cel

-55 Cel

Nickel/Palladium/Gold (Ni/Pd/Au)

DUAL

R-PDSO-G8

1

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

.01 mA

e4

NOT SPECIFIED

260

2.3 mm

LVC/LCX/Z

SN74LVC1G99DCUT

Texas Instruments

MAJORITY LOGIC GATE

AUTOMOTIVE

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

YES

1

CMOS

4

TR

1.8

3.3

50 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

32.8 ns

32 Amp

Gates

.5 mm

125 Cel

3-STATE

-40 Cel

Matte Tin (Sn)

DUAL

R-PDSO-G8

1

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

.01 mA

e3

NOT SPECIFIED

260

2.3 mm

LVC/LCX/Z

SN74AUC2G08DCURG4

Texas Instruments

AND GATE

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.2

1.2/2.5

15 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

3 ns

9 Amp

Gates

.5 mm

85 Cel

3-STATE

-40 Cel

Nickel/Palladium/Gold (Ni/Pd/Au)

DUAL

R-PDSO-G8

1

2.7 V

.9 mm

2 mm

Not Qualified

.8 V

.01 mA

e4

NOT SPECIFIED

260

2.3 mm

AUC

SN74LVC2G86YZAR

Texas Instruments

XOR GATE

INDUSTRIAL

BALL

8

VFBGA

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.8

3.3

50 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA8,2X4,20

9.9 ns

24 Amp

Gates

.5 mm

85 Cel

-40 Cel

TIN SILVER COPPER

BOTTOM

R-PBGA-B8

1

5.5 V

.5 mm

.9 mm

Not Qualified

1.65 V

e1

1.9 mm

LVC/LCX/Z

SN74LVC2G38DCURG4

Texas Instruments

NAND GATE

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.8

3.3

50 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

10 ns

24 Amp

Gates

.5 mm

85 Cel

OPEN-DRAIN

-40 Cel

NICKEL PALLADIUM GOLD

DUAL

R-PDSO-G8

1

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

e4

30

260

2.3 mm

LVC/LCX/Z

SN74AHC2G00HDCU3

Texas Instruments

NAND GATE

INDUSTRIAL

GULL WING

8

SOP

RECTANGULAR

PLASTIC/EPOXY

YES

2

CMOS

2

5

SMALL OUTLINE

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

2 V

AHC/VHC/H/U/V

SN74LVC2GU04DCTR

Texas Instruments

INVERTER

INDUSTRIAL

GULL WING

8

LSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

3

CMOS

1

TR

5

3.3

SMALL OUTLINE, LOW PROFILE, SHRINK PITCH

SSOP8,.16

24 Amp

Gates

.65 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

1.3 mm

2.8 mm

Not Qualified

1.65 V

NOT SPECIFIED

NOT SPECIFIED

2.95 mm

LVC/LCX/Z

SN74LVC2G08IDCURQ1

Texas Instruments

AND GATE

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

AEC-Q100

2

TR

1.8

3.3

50 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

9 ns

24 Amp

Gates

.5 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

2.3 mm

LVC/LCX/Z

SN74AUP2G08RSER

Texas Instruments

AND GATE

INDUSTRIAL

NO LEAD

8

HVQCCN

SQUARE

UNSPECIFIED

NO

YES

2

CMOS

2

TR

3

1.2/3.3

30 pF

CHIP CARRIER, HEAT SINK/SLUG, VERY THIN PROFILE

LCC8,.06SQ,20

27 ns

4 Amp

Gates

.5 mm

85 Cel

3-STATE

-40 Cel

NICKEL PALLADIUM GOLD SILVER

QUAD

S-XQCC-N8

1

3.6 V

.6 mm

1.5 mm

Not Qualified

.8 V

.0009 mA

e4

30

260

1.5 mm

AUP/ULP/V

SN74LVC3G17YEPR

Texas Instruments

BUFFER

INDUSTRIAL

BALL

8

VFBGA

RECTANGULAR

UNSPECIFIED

YES

YES

3

CMOS

1

TR

1.8

3.3

50 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA8,2X4,20

9.2 ns

24 Amp

Gates

.5 mm

85 Cel

-40 Cel

TIN LEAD

BOTTOM

R-XBGA-B8

1

5.5 V

.5 mm

.9 mm

Not Qualified

1.65 V

e0

1.9 mm

LVC/LCX/Z

74LVC2G132DCURE4

Texas Instruments

NAND GATE

AUTOMOTIVE

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

YES

2

CMOS

2

TR

1.8

3.3

50 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

16 ns

24 Amp

Gates

.5 mm

125 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

NOT SPECIFIED

NOT SPECIFIED

2.3 mm

LVC/LCX/Z

SN74AS8003PSR

Texas Instruments

NAND GATE

COMMERCIAL

GULL WING

8

SOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

TTL

2

TR

5

5

SMALL OUTLINE

SOP8,.3

4.5 ns

20 Amp

Gates

1.27 mm

70 Cel

0 Cel

DUAL

R-PDSO-G8

5.5 V

2 mm

5.3 mm

Not Qualified

4.5 V

8.7 mA

NOT SPECIFIED

NOT SPECIFIED

6.2 mm

AS

SN74AUP3G06DQER

Texas Instruments

INVERTER

INDUSTRIAL

NO LEAD

8

HSON

RECTANGULAR

PLASTIC/EPOXY

NO

YES

3

CMOS

1

N/A

TR

1.2

1.2/3.3

30 pF

SMALL OUTLINE, HEAT SINK/SLUG

SOLCC8,.04,14

19.3 ns

4 Amp

Gates

.35 mm

85 Cel

OPEN-DRAIN

-40 Cel

NICKEL PALLADIUM GOLD SILVER

DUAL

R-PDSO-N8

1

3.6 V

.4 mm

1 mm

Not Qualified

.8 V

.01 mA

e4

30

260

1.4 mm

AUP/ULP/V

SN74AUC2G32YZPR

Texas Instruments

OR GATE

INDUSTRIAL

BALL

8

VFBGA

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.2

1.2/2.5

15 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA8,2X4,20

3.3 ns

9 Amp

Gates

.5 mm

85 Cel

3-STATE

-40 Cel

Tin/Silver/Copper (Sn/Ag/Cu)

BOTTOM

R-PBGA-B8

1

2.7 V

.5 mm

.9 mm

Not Qualified

.8 V

.01 mA

e1

NOT SPECIFIED

260

1.4 mm

AUC

SN74AUC2G00YEPR

Texas Instruments

NAND GATE

INDUSTRIAL

BALL

8

VFBGA

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.2

1.2/2.5

15 pF

GRID ARRAY, VERY THIN PROFILE, FINE PITCH

BGA8,2X4,20

2.5 ns

5 Amp

Gates

.5 mm

85 Cel

3-STATE

-40 Cel

BOTTOM

R-PBGA-B8

2.7 V

.5 mm

.9 mm

Not Qualified

.8 V

NOT SPECIFIED

NOT SPECIFIED

1.9 mm

AUC

CD40107BPS

Texas Instruments

NAND GATE

MILITARY

GULL WING

8

SOP

RECTANGULAR

PLASTIC/EPOXY

YES

2

CMOS

2

5

SMALL OUTLINE

200 ns

1.27 mm

125 Cel

OPEN-DRAIN

-55 Cel

NICKEL PALLADIUM GOLD

DUAL

R-PDSO-G8

1

18 V

2 mm

5.3 mm

Not Qualified

3 V

e4

6.2 mm

4000/14000/40000

SN74LVC2G00DCT

Texas Instruments

NAND GATE

INDUSTRIAL

GULL WING

8

LSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

2

CMOS

2

1.8

SMALL OUTLINE, LOW PROFILE, SHRINK PITCH

8.6 ns

.65 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

1.3 mm

2.8 mm

Not Qualified

1.65 V

2.95 mm

LVC/LCX/Z

74LVC2G132DCURG4

Texas Instruments

NAND GATE

AUTOMOTIVE

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

YES

YES

2

CMOS

2

TR

1.8

3.3

50 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

16 ns

32 Amp

Gates

.5 mm

125 Cel

-40 Cel

Nickel/Palladium/Gold (Ni/Pd/Au)

DUAL

R-PDSO-G8

1

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

.01 mA

e4

NOT SPECIFIED

260

2.3 mm

LVC/LCX/Z

SN74AUC2G02DCURE4

Texas Instruments

NOR GATE

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

2

CMOS

2

TR

1.2

1.2/2.5

15 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

3.5 ns

5 Amp

Gates

.5 mm

85 Cel

3-STATE

-40 Cel

NICKEL PALLADIUM GOLD

DUAL

R-PDSO-G8

1

2.7 V

.9 mm

2 mm

Not Qualified

.8 V

e4

30

260

2.3 mm

AUC

SN74LVC3GU04DCUT

Texas Instruments

INVERTER

INDUSTRIAL

GULL WING

8

VSSOP

RECTANGULAR

PLASTIC/EPOXY

NO

YES

3

CMOS

1

TR

1.8

3.3

50 pF

SMALL OUTLINE, VERY THIN PROFILE, SHRINK PITCH

TSSOP8,.12,20

9.2 ns

24 Amp

Gates

.5 mm

85 Cel

-40 Cel

DUAL

R-PDSO-G8

5.5 V

.9 mm

2 mm

Not Qualified

1.65 V

2.3 mm

LVC/LCX/Z

Logic Gates

Logic gates are electronic circuits that perform basic logical operations on one or more inputs to produce a single output. They are the building blocks of digital circuits and are used to implement digital logic functions, such as AND, OR, NOT, XOR, and NAND.

Logic gates are designed using various technologies, including transistor-transistor logic (TTL), complementary metal-oxide-semiconductor (CMOS), and field-programmable gate arrays (FPGAs). They can be classified into three main types based on their operation: combinational logic gates, sequential logic gates, and programmable logic gates.

Combinational logic gates are logic gates that produce an output based solely on the current input values. These gates include the AND gate, OR gate, NOT gate, XOR gate, and NAND gate. The output of a combinational logic gate depends on the input values and the logic function implemented by the gate.

Sequential logic gates are logic gates that have memory elements and can store information. These gates include the SR flip-flop, D flip-flop, JK flip-flop, and T flip-flop. The output of a sequential logic gate depends on the current input values and the previous state of the gate.

Programmable logic gates are logic gates that can be programmed to implement different logic functions. These gates include programmable logic arrays (PLAs), programmable array logic (PALs), and field-programmable gate arrays (FPGAs). Programmable logic gates can be reprogrammed to adapt to changing system requirements.

Logic gates are used in various applications, including digital signal processing, control systems, and memory systems. They are essential components of digital systems and can be found in many electronic devices, such as computers, mobile phones, and digital cameras.