Broadcom ATM/SONET/SDH Circuits 669

Reset All
Part RoHS Manufacturer Telecom IC Type Temperature Grade Terminal Form No. of Terminals Package Code Package Shape Package Body Material Applications Surface Mount No. of Functions No. of Channels Technology Nominal Negative Supply Voltage Maximum Supply Current Nominal Supply Voltage Power Supplies (V) Package Style (Meter) Package Equivalence Code Sub-Category Terminal Pitch Maximum Operating Temperature Minimum Operating Temperature Terminal Finish Terminal Position Data Rate JESD-30 Code Moisture Sensitivity Level (MSL) Maximum Seated Height Width Qualification Additional Features JESD-609 Code Maximum Time At Peak Reflow Temperature (s) Peak Reflow Temperature (C) Length

C488T227

Broadcom

ATM/SONET/SDH TRANSMITTER

COMMERCIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

NO

1

-5.2 V

5 V

FIBER OPTIC

70 Cel

0 Cel

TIN LEAD

DUAL

R-XDFO-X

Not Qualified

e0

NOT SPECIFIED

NOT SPECIFIED

LG1600KXH2666

Broadcom

ATM/SONET/SDH CLOCK RECOVERY CIRCUIT

COMMERCIAL

GULL WING

68

QFP

SQUARE

PLASTIC/EPOXY

YES

1

5 V

FLATPACK

1.27 mm

70 Cel

0 Cel

TIN LEAD

QUAD

S-PQFP-G68

4.3942 mm

29.972 mm

Not Qualified

e0

30

225

29.972 mm

1319MR

Broadcom

ATM/SONET/SDH RECEIVER

GULL WING

14

RECTANGULAR

UNSPECIFIED

YES

1

-5.2 V

FIBER OPTIC

TIN LEAD

DUAL

R-XDFO-G14

Not Qualified

e0

NOT SPECIFIED

NOT SPECIFIED

TMXL33625BL-2

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

INDUSTRIAL

BALL

1152

BGA

SQUARE

PLASTIC/EPOXY

YES

1

1.5 V

GRID ARRAY

1.27 mm

85 Cel

-40 Cel

TIN LEAD

BOTTOM

S-PBGA-B1152

2.51 mm

45 mm

Not Qualified

e0

30

225

45 mm

HFBR-5102#0FN

Broadcom

ATM/SONET/SDH TRANSCEIVER

COMMERCIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

NO

1

5 V

FIBER OPTIC

70 Cel

0 Cel

UNSPECIFIED

R-XXFO-X

Not Qualified

D2570H61

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

LSC2110-622-SF

Broadcom

ATM/SONET/SDH TRANSMITTER

INDUSTRIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

NO

1

FIBER OPTIC

85 Cel

-40 Cel

UNSPECIFIED

R-XXFO-X

Not Qualified

D2570H904

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

LSC2606-FP

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

COMMERCIAL

FLAT

14

RECTANGULAR

UNSPECIFIED

YES

1

FIBER OPTIC

70 Cel

-20 Cel

DUAL

R-XDFO-F14

Not Qualified

LSC2684-FP

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

COMMERCIAL

FLAT

14

RECTANGULAR

UNSPECIFIED

YES

1

FIBER OPTIC

70 Cel

-20 Cel

DUAL

R-XDFO-F14

Not Qualified

LSC2110-622-DN

Broadcom

ATM/SONET/SDH TRANSMITTER

INDUSTRIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

NO

1

FIBER OPTIC

85 Cel

-40 Cel

UNSPECIFIED

R-XXFO-X

Not Qualified

D171C004BAA

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

INDUSTRIAL

THROUGH-HOLE

4

RECTANGULAR

UNSPECIFIED

NO

1

FIBER OPTIC

85 Cel

-40 Cel

TIN LEAD

DUAL

R-XDFO-T4

Not Qualified

e0

NOT SPECIFIED

NOT SPECIFIED

1310N

Broadcom

ATM/SONET/SDH RECEIVER

INDUSTRIAL

PIN/PEG

14

RECTANGULAR

UNSPECIFIED

NO

1

5 V

FIBER OPTIC

85 Cel

-40 Cel

TIN LEAD

DUAL

R-XDFO-P14

Not Qualified

e0

NOT SPECIFIED

NOT SPECIFIED

D2555G25

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

1319PC

Broadcom

ATM/SONET/SDH RECEIVER

INDUSTRIAL

GULL WING

14

RECTANGULAR

UNSPECIFIED

YES

1

-5.2 V

5 V

FIBER OPTIC

85 Cel

-40 Cel

TIN LEAD

DUAL

R-XDFO-G14

Not Qualified

e0

NOT SPECIFIED

NOT SPECIFIED

D2570H22

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

D2526G877

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

P171A014BAA

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

INDUSTRIAL

THROUGH-HOLE

4

RECTANGULAR

METAL

NO

1

5 V

FIBER OPTIC

85 Cel

-40 Cel

TIN LEAD

DUAL

R-MDFO-T4

Not Qualified

e0

HFBR-5208M

Broadcom

ATM/SONET/SDH TRANSCEIVER

COMMERCIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

ATM; SDH; SONET

NO

1

5 V

FIBER OPTIC

70 Cel

0 Cel

UNSPECIFIED

R-XXFO-X

Not Qualified

NOT SPECIFIED

NOT SPECIFIED

D2570H889

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

HFCT-5208AM

Broadcom

ATM/SONET/SDH TRANSCEIVER

INDUSTRIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

ATM; SDH; SONET

NO

1

5 V

FIBER OPTIC

85 Cel

-40 Cel

UNSPECIFIED

R-XXFO-X

Not Qualified

NOT SPECIFIED

NOT SPECIFIED

LSC2658-FP

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

COMMERCIAL

FLAT

14

RECTANGULAR

UNSPECIFIED

YES

1

FIBER OPTIC

70 Cel

-20 Cel

DUAL

R-XDFO-F14

Not Qualified

XMT5170B-622-SC

Broadcom

ATM/SONET/SDH TRANSMITTER

COMMERCIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

NO

1

5 V

FIBER OPTIC

70 Cel

0 Cel

UNSPECIFIED

R-XXFO-X

Not Qualified

D2570H895

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

D2555G34

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

C488T219

Broadcom

ATM/SONET/SDH TRANSMITTER

COMMERCIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

NO

1

-5.2 V

5 V

FIBER OPTIC

70 Cel

0 Cel

TIN LEAD

DUAL

R-XDFO-X

Not Qualified

e0

NOT SPECIFIED

NOT SPECIFIED

L-TMXL846221BL-3

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

INDUSTRIAL

BALL

700

BGA

SQUARE

PLASTIC/EPOXY

YES

1

1.5 V

GRID ARRAY

1 mm

85 Cel

-40 Cel

TIN SILVER COPPER

BOTTOM

S-PBGA-B700

2.51 mm

35 mm

Not Qualified

e1

40

250

35 mm

D2526G867

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

XMT5170B-622-FP

Broadcom

ATM/SONET/SDH TRANSMITTER

COMMERCIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

NO

1

5 V

FIBER OPTIC

70 Cel

0 Cel

UNSPECIFIED

R-XXFO-X

Not Qualified

HFBR-5101#ALL

Broadcom

ATM/SONET/SDH TRANSCEIVER

COMMERCIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

NO

1

5 V

FIBER OPTIC

70 Cel

0 Cel

UNSPECIFIED

R-XXFO-X

Not Qualified

D2526G884

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

D2555G39

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

HFBR-5208

Broadcom

ATM/SONET/SDH TRANSCEIVER

COMMERCIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

NO

1

5 V

FIBER OPTIC

70 Cel

0 Cel

UNSPECIFIED

R-XXFO-X

Not Qualified

NOT SPECIFIED

NOT SPECIFIED

D2570H866

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

D171C004BAF

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

INDUSTRIAL

THROUGH-HOLE

4

RECTANGULAR

UNSPECIFIED

NO

1

FIBER OPTIC

85 Cel

-40 Cel

TIN LEAD

DUAL

R-XDFO-T4

Not Qualified

e0

NOT SPECIFIED

NOT SPECIFIED

D2570H897

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

LSC2110-622-ST

Broadcom

ATM/SONET/SDH TRANSMITTER

INDUSTRIAL

UNSPECIFIED

RECTANGULAR

UNSPECIFIED

NO

1

FIBER OPTIC

85 Cel

-40 Cel

UNSPECIFIED

R-XXFO-X

Not Qualified

D2526G897

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

L-TMXL336251BL-3

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

INDUSTRIAL

BALL

1152

BGA

SQUARE

PLASTIC/EPOXY

YES

1

1.5 V

GRID ARRAY

1.27 mm

85 Cel

-40 Cel

TIN SILVER COPPER

BOTTOM

S-PBGA-B1152

2.51 mm

45 mm

Not Qualified

e1

40

245

45 mm

PPA1052-D-FP

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

INDUSTRIAL

UNSPECIFIED

4

UNSPECIFIED

UNSPECIFIED

NO

1

5 V

FIBER OPTIC

85 Cel

-40 Cel

UNSPECIFIED

X-XXFO-X4

Not Qualified

M-TDAT162G52-3BAL2

Broadcom

INDUSTRIAL

BALL

792

BGA

SQUARE

PLASTIC/EPOXY

YES

CMOS

1.6/3.3

GRID ARRAY

BGA792,39X39,40

ATM/SONET/SDH ICs

1 mm

85 Cel

-40 Cel

BOTTOM

S-PBGA-B792

Not Qualified

D171C004CAN

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

INDUSTRIAL

THROUGH-HOLE

4

RECTANGULAR

UNSPECIFIED

NO

1

FIBER OPTIC

85 Cel

-40 Cel

TIN LEAD

DUAL

R-XDFO-T4

Not Qualified

e0

D2526G27

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

TLMA0110G

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

COMMERCIAL

GULL WING

24

QFP

RECTANGULAR

PLASTIC/EPOXY

YES

1

-5.2 V

FLATPACK

.8 mm

70 Cel

0 Cel

TIN LEAD

QUAD

R-PQFP-G24

6.9596 mm

Not Qualified

e0

30

240

8.4328 mm

LST2525-T-ST

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

INDUSTRIAL

UNSPECIFIED

4

UNSPECIFIED

UNSPECIFIED

SDH; SONET

NO

1

FLANGE MOUNT

85 Cel

-40 Cel

UNSPECIFIED

X-XXFM-X4

Not Qualified

NOT SPECIFIED

NOT SPECIFIED

L644360A2WV3E41FAA

Broadcom

ATM/SONET/SDH SEGMENTATION AND REASSEMBLY DEVICE

COMMERCIAL

GULL WING

208

QFP

SQUARE

METAL

YES

CMOS

5 V

5

FLATPACK

QFP208,1.2SQ,20

ATM/SONET/SDH ICs

.5 mm

70 Cel

0 Cel

Tin/Lead (Sn/Pb)

QUAD

S-MQFP-G208

Not Qualified

e0

D2526G898

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

D2526G32

Broadcom

ATM/SONET/SDH SUPPORT CIRCUIT

FLAT

14

RECTANGULAR

UNSPECIFIED

SDH; SONET

YES

1

FIBER OPTIC

DUAL

R-XDFO-F14

Not Qualified

ATM/SONET/SDH Circuits

ATM (Asynchronous Transfer Mode), SONET (Synchronous Optical Network), and SDH (Synchronous Digital Hierarchy) circuits are high-speed communication technologies used in telecommunications networks.

ATM is a cell-based network technology that enables high-speed data transfer, video and voice communication. It divides data into fixed-size cells and sends them across the network using time-division multiplexing (TDM).

SONET and SDH are both standard protocols for optical telecommunications transport. They use synchronous timing signals to enable high-speed communication over fiber optic networks. SONET is used primarily in North America, while SDH is used primarily in Europe and other regions.

ATM, SONET, and SDH circuits offer several advantages over other communication technologies. They provide high-speed communication with low latency, allowing for efficient data transfer and real-time voice and video communication. They also provide a high level of reliability and fault tolerance, making them ideal for use in mission-critical applications such as banking, healthcare, and defense.

However, these circuits also require specialized hardware and software, and can be more expensive to implement and maintain than other communication technologies. They also require a high level of expertise to configure and manage.