Magnetic Circuit Breaker Circuit Breaker 327

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

209-1-1-62-4-9-10

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

10 A

Stud

5 kA

Toggle

5.125 in (130.18 mm)

1.026 in (26.06 mm)

Moisture Resistant

Trip Free

3.55 in (90.17 mm)

CSA; CUL; UL

1

209-1-1-62-4-9-15-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

15 A

Stud

5 kA

Toggle

5.125 in (130.18 mm)

1.026 in (26.06 mm)

Moisture Resistant

Trip Free

3.55 in (90.17 mm)

CSA; CUL; UL; VDE

1

S202MUC-Z10

Abb

Magnetic Circuit Breaker

DIN Rail Mount

480 V

500 V

10 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle Handle

Bulk

3.465 in (88 mm)

1.378 in (35 mm)

IP20; IP40

Trip

2.717 in (69 mm)

CSA; UL; VDE

2

55 °C (131 °F)

203-22-1-66-103-4-1-1

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

Quick Connect

-40 °C (-40 °F)

2 kA

Rocker

2 in (50.8 mm)

1.54 in (39.12 mm)

Series Trip

1.77 in (44.96 mm)

CSA; UL

2

85 °C (185 °F)

CA1-B0-54-430-5B1-BA

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

3 A

Screw

-40 °C (-40 °F)

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

1

85 °C (185 °F)

W67-X2Q12-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

0.75 in (19.05 mm)

Fungus Resistant; Moisture Resistant

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

Standard

W67-X2Q1220

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

20 A

Quick Connect

2.2 s

Toggle

Series Trip

1

AC2-B2-26-610-144-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

W92-X112-30

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Moisture Resistant

Series Trip

1.985 in (50.42 mm)

CSA; UL; VDE

2

85 °C (185 °F)

Standard

1393255-8

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

2.25 in (57.15 mm)

Series Trip

1.845 in (46.86 mm)

3

85 °C (185 °F)

W68-X2Q12-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Fungus Resistant; Moisture Resistant

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

Standard

BA1-B0-14-450-225-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

5 A

Screw

-40 °C (-40 °F)

7.5 kA

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL

1

85 °C (185 °F)

BB3-B0-46-618-211-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

18 A

Screw

-40 °C (-40 °F)

3 kA

Handle

2.265 in (57.53 mm)

2 in (50.8 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

3

85 °C (185 °F)

W68-X2Q12-5

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

5 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Fungus Resistant; Moisture Resistant

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

Standard

W67-X2Q12-15

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

15 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

0.75 in (19.05 mm)

Fungus Resistant; Moisture Resistant

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

Standard

W67-X2Q1215

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

15 A

Quick Connect

2.2 s

Toggle

Series Trip

1

AA1-B0-34-615-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

3RV1342-4FC10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

12 kA

Rotary Handle

6.496 in (165 mm)

2.756 in (70 mm)

IP20

6.496 x 2.756 x 6.85 in (165 x 70 x 174 mm)

Trip

6.85 in (174 mm)

3

60 °C (140 °F)

AD1-B2-26-610-143-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AP12-1-51-502

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Trip Free

1.78 in (45.21 mm)

2

100 °C (212 °F)

AA1-B0-34-625-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Toggle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

W91-X112-30

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

W91-X11230

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

M55629/2-079

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

10 A

Wire/Solder

-40 °C (-40 °F)

1 kA

Rated breaking capacity at 50 VDC: 2000 A

Toggle Lever

2.53 in (64.26 mm)

0.78 in (19.81 mm)

Unsealed

2.53 x 0.78 x 2.8 in (64.26 x 19.81 x 71.12 mm)

Trip Free

2.8 in (71.12 mm)

MIL-PRF-55629/2

1

85 °C (185 °F)

Instantaneous

AA1-B0-34-620-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

20 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

W68-X2Q12-15

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

15 A

Quick Connect

5 kA

2.2 s

Toggle

50.8mm X 38.1mm X 51.89mm

Series Trip

2

W68X-2Q12-15

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

15 A

Quick Connect

2.2 s

Toggle

Series Trip

2

3RV2311-1JC10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2021-4FA10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

40 °C (104 °F)

3RV2021-4NA10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

28 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

AC1-B0-14-620-343-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

20 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

AM1-B0-14-615-901-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

15 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

2 in (50.8 mm)

0.74 in (18.8 mm)

Corrosion/Moisture Resistant

Series Trip

1.817 in (46.15 mm)

CSA; UL

1

85 °C (185 °F)

AM1-B0-14-610-901-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

10 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

2 in (50.8 mm)

0.74 in (18.8 mm)

Corrosion/Moisture Resistant

Series Trip

1.817 in (46.15 mm)

CSA; UL

1

85 °C (185 °F)

AN1-B0-20-615-113-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

15 A

Quick Connect

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Push To Reset

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

AP12-1-51-252

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

2.5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

GA1-B0-20-615-11-DC

Carling Technologies

Magnetic Circuit Breaker

DIN Rail Mount

240 V

15 A

Snap On

-40 °C (-40 °F)

3 kA

Handle

3.625 in (92.08 mm)

0.688 in (17.48 mm)

Corrosion/Moisture Resistant

Series Trip

2.62 in (66.55 mm)

CSA, UL

1

85 °C (185 °F)

MS2-B-20-615-1-1CB-A-0DC

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

15 A

Quick Connect

-40 °C (-40 °F)

2 kA

Sealed Toggle

1.375 in (34.93 mm)

1.3 in (33.02 mm)

Moisture Resistant; IP68;

Series Trip

2.158 in (54.81 mm)

CUL; UL

2

85 °C (185 °F)

W92-X112-3

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

3 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

2

85 °C (185 °F)

AP17-1-64-502

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

5 A

Screw

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

CA1-B0-34-450-A21-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

5 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B2-34-450-A21-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

5 A

Screw

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

MS1-B-10-430-2-1CB-A-A

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

3 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

1.375 in (34.93 mm)

0.656 in (16.66 mm)

IP68

Series Trip

1.634 in (41.5 mm)

1

85 °C (185 °F)

CA2-B0-21-620-622-DG

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

120 V

20 A

Stud

-40 °C (-40 °F)

10 kA

Handle

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL

2

85 °C (185 °F)

W91-X112-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

W91-X11220

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

W67-X2Q12-10

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

0.75 in (19.05 mm)

Fungus Resistant; Moisture Resistant

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

Standard

1-1393255-3

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

50 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

2.25 in (57.15 mm)

Series Trip

1.845 in (46.86 mm)

3

85 °C (185 °F)

W92-X112-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

2

85 °C (185 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.