Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
3 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
7 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
10 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Rocker |
2.5 in (63.5 mm) |
2.265 in (57.53 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; TUV; UL |
3 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
2 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Toggle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
4 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
5 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
25 A |
Quick Connect |
-40 °C (-40 °F) |
7.5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
1 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
7.5 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2.265 in (57.53 mm) |
2 in (50.8 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
3 |
85 °C (185 °F) |
|||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
2 kA |
Toggle Handle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.687 in (42.85 mm) |
VDE |
2 |
85 °C (185 °F) |
||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
8 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
||||||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
1.5 kA |
Toggle Handle |
2 in (50.8 mm) |
2.265 in (57.53 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.73 in (43.94 mm) |
CSA; UL; VDE |
3 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
10 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Rocker |
2.5 in (63.5 mm) |
2.265 in (57.53 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; TUV; UL |
3 |
85 °C (185 °F) |
|||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
160 V |
90 A |
Quick Connect |
5 kA |
Toggle Handle |
5.8 in (147.32 mm) |
2.072 in (52.63 mm) |
Moisture Resistant |
Trip Free |
2.61 in (66.29 mm) |
CSA; CUL; UL |
2 |
|||||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
25 A |
Quick Connect |
-40 °C (-40 °F) |
7.5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
65 V |
73 A |
Stud |
-40 °C (-40 °F) |
1.5 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA, UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
20 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
2.265 in (57.53 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
3 |
85 °C (185 °F) |
|||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
2 kA |
Toggle |
2 in (50.8 mm) |
0.75 in (19.05 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.687 in (42.85 mm) |
CCC; VDE |
1 |
85 °C (185 °F) |
||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
6 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
||||||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
20 A |
Screw |
-40 °C (-40 °F) |
1 kA |
Toggle |
1.562 in (39.67 mm) |
1.281 in (32.53 mm) |
Corrosion Resistant; Sealed |
Series Trip |
1.78 in (45.21 mm) |
2 |
100 °C (212 °F) |
||||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
3.5 A |
Stud |
-40 °C (-40 °F) |
7.5 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
3.5 A |
Stud |
-40 °C (-40 °F) |
7.5 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
80 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
2 kA |
Toggle Handle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.687 in (42.85 mm) |
CCC; VDE |
2 |
85 °C (185 °F) |
|||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
80 V |
10 A |
Quick Connect |
-40 °C (-40 °F) |
1 kA |
Rocker |
1.375 in (34.93 mm) |
0.68 in (17.27 mm) |
Chemical/Corrosion/Moisture Resistant |
Series Trip |
1.53 in (38.86 mm) |
UL; CSA |
1 |
85 °C (185 °F) |
||||||||||
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
65 V |
50 A |
Screw |
2.2 s |
Toggle |
Series Trip |
1 |
||||||||||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
1 A |
Stud |
5 kA |
Toggle Handle |
5.125 in (130.18 mm) |
2.072 in (52.63 mm) |
Moisture Resistant |
Trip Free |
3.55 in (90.17 mm) |
CSA; CUL; UL |
2 |
|||||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
50 A |
Stud |
5 kA |
Toggle Handle |
5.125 in (130.18 mm) |
2.072 in (52.63 mm) |
Moisture Resistant |
Trip Free |
3.55 in (90.17 mm) |
CSA; CUL; UL |
2 |
|||||||||||||
|
Siemens |
Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
63 A |
Screw And Snap On |
-20 °C (-4 °F) |
6 kA |
Rotary Handle |
6.496 in (165 mm) |
2.756 in (70 mm) |
IP20 |
6.496 x 2.756 x 6.85 in (165 x 70 x 174 mm) |
Trip |
6.85 in (174 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
5 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
25 A |
Screw |
-40 °C (-40 °F) |
3 kA |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.73 in (43.94 mm) |
UL; TUV |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
25 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Handle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.73 in (43.94 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
80 V |
25 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Handle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.73 in (43.94 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
1 A |
Stud |
-40 °C (-40 °F) |
Toggle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
10 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
10 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
80 V |
10 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
10 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
1.515 in (38.48 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
2 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
50 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Rocker |
2.5 in (63.5 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.16 in (54.86 mm) |
CSA; UL; VDE |
2 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
10 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
500 V |
20 A |
Screw |
-40 °C (-40 °F) |
10 kA |
Handle |
3.672 in (93.26 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.264 in (57.51 mm) |
UL |
2 |
85 °C (185 °F) |
||||||||||
|
Altech |
Magnetic Circuit Breaker |
DIN Rail Mount |
240 V |
20 A |
Snap On |
10 kA |
Toggle |
4.134 in (105 mm) |
1.378 in (35 mm) |
Trip |
2.362 in (60 mm) |
CUL; UL |
1 |
|||||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
30 A |
Screw |
5 kA |
Toggle Handle |
2.49 in (63.24 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.859 in (47.22 mm) |
CCC; VDE |
2 |
||||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
80 V |
1 A |
Quick Connect |
-40 °C (-40 °F) |
1 kA |
Illuminated Rocker |
1.375 in (34.93 mm) |
0.68 in (17.27 mm) |
Chemical/Corrosion/Moisture Resistant |
Series Trip |
1.53 in (38.86 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
80 V |
1 A |
Quick Connect |
-40 °C (-40 °F) |
1 kA |
Push-Pull |
1.375 in (34.93 mm) |
0.68 in (17.27 mm) |
Chemical/Corrosion/Moisture Resistant |
Series Trip |
1.484 in (37.69 mm) |
UL; CSA |
1 |
85 °C (185 °F) |
||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
30 A |
Quick Connect |
2.5 kA |
2.2 s |
Toggle |
Series Trip |
2 |
||||||||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
40 A |
Stud |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2.5 in (63.5 mm) |
2.25 in (57.15 mm) |
Series Trip |
1.845 in (46.86 mm) |
3 |
85 °C (185 °F) |
|||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
8 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
||||||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
30 A |
Quick Connect |
2.2 s |
Toggle |
Series Trip |
3 |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.