Magnetic Circuit Breaker Circuit Breaker 327

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

NC1V-1111F-20AA

Idec

Magnetic Circuit Breaker

DIN Rail Mount

250 V

65 V

20 A

Snap On

-10 °C (14 °F)

2.5 kA

Toggle

2.811 in (71.4 mm)

0.689 in (17.5 mm)

IP20

Series Trip

2.598 in (66 mm)

CCC; CE; CSA; PSE; TUV; UL

1

60 °C (140 °F)

NC1V-3113-1AA

Idec

Magnetic Circuit Breaker

DIN Rail Mount

250 V

1 A

Snap On

-10 °C (14 °F)

2.5 kA

Toggle Handle

2.811 in (71.4 mm)

2.067 in (52.5 mm)

IP20

Series Trip

2.598 in (66 mm)

CCC; CE; CSA; PSE; TUV; UL

3

60 °C (140 °F)

W67-X2Q52-25

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

65 V

25 A

Quick Connect

2.2 s

Toggle

Series Trip

1

0903041

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

24 V

500 mA

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

219-3-1-66-8-2-30-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

30 A

Quick Connect

10 kA

Toggle Handle

5.8 in (147.32 mm)

3.108 in (78.94 mm)

Moisture Resistant

Trip Free

2.61 in (66.29 mm)

CSA; CUL; UL; VDE

3

AA1-B0-24-620-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-26-625-3D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Toggle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-620-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

20 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-630-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

30 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AP1-1-72-103

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

10 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

0.656 in (16.66 mm)

Corrosion Resistant; Sealed

Trip Free

1.605 in (40.77 mm)

1

100 °C (212 °F)

AP12-1-61F-252

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

2.5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle Handle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Sealed

Series Trip

1.78 in (45.21 mm)

UL

2

100 °C (212 °F)

AP12-1R-41-502

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle Handle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Sealed

Series Trip

1.78 in (45.21 mm)

UL

2

100 °C (212 °F)

AP12-1RC-62-252

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

2.5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

BB2-B0-26-625-522-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

3 kA

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

2

85 °C (185 °F)

BB2-B2-26-625-522-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

3 kA

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

2

85 °C (185 °F)

CA1-B0-12-225-321-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

250 mA

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B0-16-625-622-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

25 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B0-46-625-622-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

25 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA2-B0-34-615-121-E

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

15 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

1.515 in (38.48 mm)

Series Trip

2.5 in (63.5 mm)

UL

2

85 °C (185 °F)

CA2-B0-34-615-121-I

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

15 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

1.515 in (38.48 mm)

Series Trip

2.5 in (63.5 mm)

UL

2

85 °C (185 °F)

CA2-B0-34-615-121-R

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

15 A

Stud

-40 °C (-40 °F)

5 kA

Handle

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

2

85 °C (185 °F)

CA2-B2-46-635-622-E

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

35 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

1.515 in (38.48 mm)

Series Trip

2.5 in (63.5 mm)

UL

2

85 °C (185 °F)

CA3-B0-20-615-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

15 A

Stud

-40 °C (-40 °F)

3 kA

Handle

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA, UL

3

85 °C (185 °F)

DA3-B0-20-615-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Toggle Handle

3.612 in (91.75 mm)

2.265 in (57.53 mm)

Moisture Resistant

Series Trip

2.165 in (54.99 mm)

CSA; UL

3

85 °C (185 °F)

EA1-B4-74-810-FDE-AB

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

65 V

100 A

Screw

-40 °C (-40 °F)

5 kA

Handle

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Corrosion/Moisture Resistant

Series Trip

2.61 in (66.3 mm)

CSA; UL

1

85 °C (185 °F)

EA1-B4-74-810-GDE-AB

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

65 V

100 A

Screw

-40 °C (-40 °F)

5 kA

Handle

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Corrosion/Moisture Resistant

Series Trip

2.61 in (66.3 mm)

CSA; UL

1

85 °C (185 °F)

LELH11-1-62-15.0-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

15 A

Screw

5 kA

Toggle Handle

2.49 in (63.24 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

2

LELH11-1-62-20.0-91-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Screw

5 kA

Toggle Handle

2.49 in (63.24 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

2

LELH11-1-62F-10.0-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

10 A

Screw

5 kA

Toggle Handle

2.49 in (63.24 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

2

LELH111-1-62-35.0-01

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

35 A

Screw

5 kA

Toggle Handle

2.49 in (63.24 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

3

MS1-B-14-630-3-1BB-A-A

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

30 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

1.375 in (34.93 mm)

0.656 in (16.66 mm)

IP68

Series Trip

1.634 in (41.5 mm)

1

85 °C (185 °F)

MS1-B-14-630-3-1CB-A-A

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

30 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

1.375 in (34.93 mm)

0.656 in (16.66 mm)

IP68

Series Trip

1.634 in (41.5 mm)

1

85 °C (185 °F)

MS1-B-14-630-3-1CB-A-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

30 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

1.375 in (34.93 mm)

0.656 in (16.66 mm)

IP68

Series Trip

1.634 in (41.5 mm)

CSA; CUL; UL

1

85 °C (185 °F)

NRBM3100-20AAA

Idec

Magnetic Circuit Breaker

Panel Mount

250 V

20 A

Stud

-40 °C (-40 °F)

1 kA

Lever

2.48 in (63 mm)

2.256 in (57.3 mm)

Series Trip

1.87 in (47.5 mm)

CCC; CE; CUL; PSE; UL; VDE

3

85 °C (185 °F)

W68-X2Q12-3

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

3 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Fungus Resistant; Moisture Resistant

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

Standard

W91-X112-2

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

2 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

W91-X113-15

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

15 A

Stud

-40 °C (-40 °F)

5 kA

150 ms

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

EA3-B0-64-475-22A-DF

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

7.5 A

Stud

-40 °C (-40 °F)

5 kA

Handle

5.78 in (146.81 mm)

3.138 in (79.7 mm)

Corrosion/Moisture Resistant

Series Trip

2.61 in (66.3 mm)

CSA; UL; VDE

3

85 °C (185 °F)

W68-X2Q12-7

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

7 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Fungus Resistant; Moisture Resistant

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

Standard

0903026

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

4 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

1110984

Phoenix Contact

Magnetic Circuit Breaker

1110991

Phoenix Contact

Magnetic Circuit Breaker

AM1R-D3-AC07-D-A-5-2

Eaton Corporation

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

5 A

Screw

-40 °C (-40 °F)

5 kA

Handle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

2.146 in (54.51 mm)

CSA; UL; TUV

1

85 °C (185 °F)

Medium

KD1-5

Eaton Corporation

Magnetic Circuit Breaker

Panel Mount

5 A

Quick Connect

KD

Push Button

0.63 in (16 mm)

Moisture Resistant

0.63 x 1.409 in (16 x 35.8 mm)

1.409 in (35.8 mm)

CSA; UL

1

0903046

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

24 V

6 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

1110987

Phoenix Contact

Magnetic Circuit Breaker

1115649

Phoenix Contact

Magnetic Circuit Breaker

1157285

Phoenix Contact

Magnetic Circuit Breaker

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.