Panel Mount Circuit Breaker 535

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

5-1423674-4

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

25 A

Quick Connect

0 °C (32 °F)

1 kA

5 s

Push To Reset

1.378 in (35 mm)

0.575 in (14.6 mm)

Series Trip

1.22 in (31 mm)

1

60 °C (140 °F)

AA1-B0-14-625-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

25 A

Quick Connect

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

CA1-B0-14-673-321-I

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

65 V

73 A

Stud

-40 °C (-40 °F)

1.5 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA, UL

1

85 °C (185 °F)

CA3-B0-22-620-122-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

20 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

2.265 in (57.53 mm)

Series Trip

2.5 in (63.5 mm)

UL

3

85 °C (185 °F)

CLB-103-27E6A-B-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

IEG1-1-61-20.0-91-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Quick Connect

-40 °C (-40 °F)

2 kA

Toggle

2 in (50.8 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Trip Free

1.687 in (42.85 mm)

CCC; VDE

1

85 °C (185 °F)

PDLA-150

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

30 V

150 A

Screw

Push Button

3.125 in (79.38 mm)

1.859 in (47.22 mm)

Trip

1.078 in (27.38 mm)

CCC

PDLA-150-I

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

30 V

150 A

Screw

Push Button

3.125 in (79.38 mm)

1.859 in (47.22 mm)

Trip

1.078 in (27.38 mm)

CCC

TS-709-5

Schurter Ag

Thermal Circuit Breaker

Panel Mount

125 V

32 V

5 A

Quick Connect

1 kA

Push To Reset

1.161 in (29.5 mm)

0.563 in (14.3 mm)

Trip Free

0.886 in (22.5 mm)

UL

1

W33-S1N1Q-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

483-G411-K1M1-A1S0ZN--10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

10 A

Screw

-55 °C (-67 °F)

2.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

0.768 x 0.559 x 1.22 in (19.5 x 14.2 x 31 mm)

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

5SU1354-6KK16

Siemens

Thermal Circuit Breaker

Panel Mount

240 V

16 A

Screw

-25 °C (-13 °F)

10 kA

3.543 in (90 mm)

1.394 in (35.4 mm)

IP20

Trip

3 in (76.2 mm)

CCC; CE; IMQ; RCM; VDE

2

55 °C (131 °F)

6752-100-50

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

120 V

28 V

50 A

Screw

3.5 kA

1 s

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

2.189 in (55.6 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

2.189 x 0.75 x 1.93 in (55.6 x 19.05 x 49.02 mm)

Trip

1.93 in (49.02 mm)

1

AP17-1-61-203

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Screw

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

CA1-B2-16-435-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

3.5 A

Stud

-40 °C (-40 °F)

7.5 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL

1

85 °C (185 °F)

CA1-B2-16-435-AB1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

3.5 A

Stud

-40 °C (-40 °F)

7.5 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL

1

85 °C (185 °F)

CLB-103-27E3A-W-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E3N-B-F

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Screw

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E3N-W-F

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Screw

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E6N-W-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

IEG11-1REC4-72-20.0-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

80 V

20 A

Quick Connect

-40 °C (-40 °F)

2 kA

Toggle Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.687 in (42.85 mm)

CCC; VDE

2

85 °C (185 °F)

MD1-B-34-610-1-A42-B-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

80 V

10 A

Quick Connect

-40 °C (-40 °F)

1 kA

Rocker

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.53 in (38.86 mm)

UL; CSA

1

85 °C (185 °F)

MS25361-50

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

120 V

28 V

50 A

Screw

3.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

2.189 in (55.6 mm)

0.75 in (19.05 mm)

Corrosion Resistant; Moisture Resistant

2.56 in (65.02 mm)

MIL-C-5809

1

PCB-B1-22-650-1AD-E12

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

50 A

Stud

-35 °C (-31 °F)

5 kA

Rocker

3.8 in (96.52 mm)

3.015 in (76.58 mm)

Moisture Resistant

Series Trip

2.975 in (75.57 mm)

UL

2

66 °C (150.8 °F)

W58-XB1A4A-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

1 kA

6 s

Rated breaking capacity at 50 VDC: 2000 A

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm)

Series Trip

1.375 in (34.93 mm)

CSA; UL

1

W58-XC4C12A-1

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1 A

Lug

1 kA

10 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

W67-X2T52-50

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

65 V

50 A

Screw

2.2 s

Toggle

Series Trip

1

229-2-1-61-8-8-1-A

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

1 A

Stud

5 kA

Toggle Handle

5.125 in (130.18 mm)

2.072 in (52.63 mm)

Moisture Resistant

Trip Free

3.55 in (90.17 mm)

CSA; CUL; UL

2

229-2-1-61-8-9-50-A

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

50 A

Stud

5 kA

Toggle Handle

5.125 in (130.18 mm)

2.072 in (52.63 mm)

Moisture Resistant

Trip Free

3.55 in (90.17 mm)

CSA; CUL; UL

2

3120-F323-P7T1-W01D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 A

Rocker

2.126 in (54 mm)

0.827 in (21 mm)

Corrosion Resistant

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3120-F323-P7T1-W19FG4-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Tab/Blade

-30 °C (-22 °F)

5 kA

Rocker

Bulk

2.126 in (54 mm)

0.984 in (25 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CSA; UL

2

60 °C (140 °F)

3120-F521-P7T1-W01D-1.5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1.5 A

Quick Connect

-30 °C (-22 °F)

15 A

Rocker

1.89 in (48 mm)

0.827 in (21 mm)

Corrosion Resistant

1.89 x 0.827 x 1.299 in (48 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3VA5110-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3VA5110-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3VA5120-6ED21-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

250 V

20 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

2 in (50.8 mm)

IP40

5.5 x 2 x 3 in (139.7 x 50.8 x 76.2 mm)

Trip

3 in (76.2 mm)

2

70 °C (158 °F)

3VA5210-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

3VA5210-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

4404.0018

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

48 V

3 A

Quick Connect

-5 °C (23 °F)

2 kA

Reset Type

Bulk

0.606 in (15.4 mm)

0.535 in (13.6 mm)

IP40

Trip Free

1.339 in (34 mm)

CCC; CSA; GB; IEC; UL; VDE

1

60 °C (140 °F)

4435.0029

Schurter Ag

Thermal Circuit Breaker

Panel Mount

277 V

32 V

2 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

0.689 in (17.5 mm)

Trip

1.319 in (33.5 mm)

CCC; CUL; UL; VDE

1

60 °C (140 °F)

4435.005

Schurter Ag

Thermal Circuit Breaker

Panel Mount

415 V

10 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.594 in (40.5 mm)

1.417 in (36 mm)

IP40

Manual On/Off

1.736 in (44.1 mm)

CCC; CUL; UL; VDE

3

60 °C (140 °F)

482-G111-K1M1-A1S0-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

72 V

30 A

Screw

-55 °C (-67 °F)

5 kA

Push-Pull

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.969 in (50 mm)

CSA; CUL; UL

1

75 °C (167 °F)

483-G411-K1M1-A1S0ZN--5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

6-1393250-7

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Series Trip

1.535 in (38.99 mm)

1

AA1-B0-34-450-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

5 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

BA1-B2-46-625-52A-K3

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

3 kA

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

UL; TUV

1

85 °C (185 °F)

BA2-B0-46-625-521-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL

2

85 °C (185 °F)

BA2-B2-36-625-525-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL

2

85 °C (185 °F)

CA1-B0-14-410-321-MF

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

1 A

Stud

-40 °C (-40 °F)

Toggle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL; VDE

1

85 °C (185 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.