Panel Mount Circuit Breaker 535

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

3120-F324-P7T1-W01D-1.5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1.5 A

Quick Connect

-30 °C (-22 °F)

15 A

Rocker

2.205 in (56 mm)

0.827 in (21 mm)

Corrosion Resistant

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3120-F324-P7T1-W01D-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

6 A

Quick Connect

-30 °C (-22 °F)

6 A

Rocker

2.205 in (56 mm)

0.827 in (21 mm)

Corrosion Resistant

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3131-AF1PT-000000-000-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

2 A

Quick Connect

-20 °C (-4 °F)

20 A

Rocker

2.008 in (51 mm)

0.945 in (24 mm)

Corrosion Resistant; IP00; IP66

Manual On/Off

1.142 in (29 mm)

UL; VDE

1

60 °C (140 °F)

3600-P10-SI-2.5A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

Panel Mount

250 V

65 V

2.5 A

Quick Connect

-30 °C (-22 °F)

1 kA

Push To Reset

1.969 in (50 mm)

0.453 in (11.5 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

2.008 in (51 mm)

CSA; UL

1

60 °C (140 °F)

3VA6210-5HM31-2AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

100 A

Screw

-25 °C (-13 °F)

35 kA

Toggle

7.8 in (198.12 mm)

4.1 in (104.14 mm)

IP40

7.8 x 4.1 x 3.4 in (198.12 x 104.14 x 86.36 mm)

Trip

3.4 in (86.36 mm)

3

70 °C (158 °F)

3VL2706-3SP33-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

500 V

63 A

Box

-25 °C (-13 °F)

100 kA

Toggle

6.87 in (174.5 mm)

4.114 in (104.5 mm)

IP20

6.87 x 4.114 x 4.193 in (174.5 x 104.5 x 106.5 mm)

Trip

4.193 in (106.5 mm)

3

70 °C (158 °F)

4-1393248-7

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

413-K14-LN2-45A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

45 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-80A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

80 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K54-N2-60A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

60 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

422191

Legrand

Thermal Magnetic Circuit Breaker

Panel Mount

400 V

250 A

Screw

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

10.236 in (260 mm)

7.205 in (183 mm)

Trip

5.669 in (144 mm)

IEC

4

70 °C (158 °F)

4411.0010

Schurter Ag

Thermal Circuit Breaker

Panel Mount

277 V

28 V

20 A

Quick Connect

-5 °C (23 °F)

1 kA

Reset Type

Bulk

1.22 in (31 mm)

0.453 in (11.5 mm)

IP40

Trip Free

1.772 in (45 mm)

CCC; CSA; GB; IEC; UL; VDE

1

60 °C (140 °F)

4435.0022

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

3 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

1.142 in (29 mm)

IP40

Trip Free

1.736 in (44.1 mm)

CCC; CSA; GB; IEC; UL; VDE

2

60 °C (140 °F)

4435.0195

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

10 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

1.142 in (29 mm)

IP40

Trip Free

1.736 in (44.1 mm)

CCC; CSA; GB; IEC; UL; VDE

2

60 °C (140 °F)

482-G111-K1M1-A1S0-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

72 V

50 A

Screw

-55 °C (-67 °F)

5 kA

Push-Pull

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.969 in (50 mm)

CSA; CUL; UL

1

75 °C (167 °F)

483-G411-K1M1-A1S0ZN--20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

20 A

Screw

-55 °C (-67 °F)

2.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

AA1-B0-21-620-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-21-620-1D2-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-450-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

5 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-610-531-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

10 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-615-331-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-615-3B1-I

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-615-3D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-615-3G2-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA2-B0-44-630-5B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AC1-B0-32-410-313-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

1 A

Screw

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

AC1-B1-14-410-243-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

1 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AF2-B0-14-620-413-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

20 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

2

85 °C (185 °F)

AF2-B0-16-610-533-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

10 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AF2-B0-44-610-531-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AJ1-B0-26-610-544-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

10 A

Screw

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

AK1-B0-32-410-1C3-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

AM2-B0-14-610-201-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

10 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

2 in (50.8 mm)

1.49 in (37.85 mm)

Corrosion/Moisture Resistant

Series Trip

1.817 in (46.15 mm)

CSA; UL

2

85 °C (185 °F)

AP12-1-52-123

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

12 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle Handle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Sealed

Series Trip

1.78 in (45.21 mm)

UL

2

100 °C (212 °F)

AP12-1-64F-302

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

3 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle Handle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Sealed

Series Trip

1.78 in (45.21 mm)

UL

2

100 °C (212 °F)

AP12-1-72-302

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

3 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

BA3-B0-46-610-531-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Screw

-40 °C (-40 °F)

1.5 kA

Toggle Handle

2 in (50.8 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

3

85 °C (185 °F)

C21-B0-20-630-41A-E

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

30 A

Stud

-40 °C (-40 °F)

7.5 kA

Rocker

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

1

85 °C (185 °F)

CA1-B0-26-210-412-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

100 mA

Stud

-40 °C (-40 °F)

5 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL; VDE

1

85 °C (185 °F)

CA1-B0-32-410-311-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

1 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B0-32-810-AG2-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

100 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B0-34-615-121-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

15 A

Stud

-40 °C (-40 °F)

5 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL; VDE

1

85 °C (185 °F)

CA2-B0-34-615-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

15 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

1.515 in (38.48 mm)

Series Trip

2.5 in (63.5 mm)

UL

2

85 °C (185 °F)

CA2-B0-34-615-121-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

15 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

1.515 in (38.48 mm)

Series Trip

2.5 in (63.5 mm)

UL

2

85 °C (185 °F)

CA3-P0-D4-825-322-MT

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

250 A

Stud

-40 °C (-40 °F)

10 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2.563 in (65.1 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

UL

3

85 °C (185 °F)

CA3-P0-D4-922-A21-MT

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

225 A

Stud

-40 °C (-40 °F)

10 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2.563 in (65.1 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

UL

3

85 °C (185 °F)

CB4-B0-24-615-1C1-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

15 A

Stud

-40 °C (-40 °F)

3 kA

Handle

2.5 in (63.5 mm)

3.015 in (76.58 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA, UL, VDE

4

85 °C (185 °F)

CM3-A0-03-670-301-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

70 A

Stud

-40 °C (-40 °F)

Toggle Handle

2.5 in (63.5 mm)

2.24 in (56.9 mm)

Corrosion/Moisture Resistant

Switch

1.85 in (47 mm)

CSA, UL

3

85 °C (185 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.