Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
1.5 A |
Quick Connect |
-30 °C (-22 °F) |
15 A |
Rocker |
2.205 in (56 mm) |
0.827 in (21 mm) |
Corrosion Resistant |
2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm) |
Manual On/Off |
1.299 in (33 mm) |
CCC; CSA; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
6 A |
Quick Connect |
-30 °C (-22 °F) |
6 A |
Rocker |
2.205 in (56 mm) |
0.827 in (21 mm) |
Corrosion Resistant |
2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm) |
Manual On/Off |
1.299 in (33 mm) |
CCC; CSA; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
28 V |
2 A |
Quick Connect |
-20 °C (-4 °F) |
20 A |
Rocker |
2.008 in (51 mm) |
0.945 in (24 mm) |
Corrosion Resistant; IP00; IP66 |
Manual On/Off |
1.142 in (29 mm) |
UL; VDE |
1 |
60 °C (140 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Magnetic Circuit Breaker |
Panel Mount |
250 V |
65 V |
2.5 A |
Quick Connect |
-30 °C (-22 °F) |
1 kA |
Push To Reset |
1.969 in (50 mm) |
0.453 in (11.5 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
2.008 in (51 mm) |
CSA; UL |
1 |
60 °C (140 °F) |
||||||||||
|
Siemens |
Thermal Circuit Breaker |
Panel Mount |
600 V |
100 A |
Screw |
-25 °C (-13 °F) |
35 kA |
Toggle |
7.8 in (198.12 mm) |
4.1 in (104.14 mm) |
IP40 |
7.8 x 4.1 x 3.4 in (198.12 x 104.14 x 86.36 mm) |
Trip |
3.4 in (86.36 mm) |
3 |
70 °C (158 °F) |
||||||||||
|
Siemens |
Thermal Circuit Breaker |
Panel Mount |
690 V |
500 V |
63 A |
Box |
-25 °C (-13 °F) |
100 kA |
Toggle |
6.87 in (174.5 mm) |
4.114 in (104.5 mm) |
IP20 |
6.87 x 4.114 x 4.193 in (174.5 x 104.5 x 106.5 mm) |
Trip |
4.193 in (106.5 mm) |
3 |
70 °C (158 °F) |
|||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
10 A |
Quick Connect |
1 kA |
3 s |
Rocker |
1.89 in (48.01 mm) |
0.98 in (24.89 mm) |
Series Trip |
1.724 in (43.79 mm) |
2 |
||||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
45 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Tease-Free And Trip-Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
80 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Tease-Free And Trip-Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
28 V |
60 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
|||||||||||
Legrand |
Thermal Magnetic Circuit Breaker |
Panel Mount |
400 V |
250 A |
Screw |
-25 °C (-13 °F) |
50 kA |
Toggle Handle |
Bulk |
10.236 in (260 mm) |
7.205 in (183 mm) |
Trip |
5.669 in (144 mm) |
IEC |
4 |
70 °C (158 °F) |
|||||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
277 V |
28 V |
20 A |
Quick Connect |
-5 °C (23 °F) |
1 kA |
Reset Type |
Bulk |
1.22 in (31 mm) |
0.453 in (11.5 mm) |
IP40 |
Trip Free |
1.772 in (45 mm) |
CCC; CSA; GB; IEC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
240 V |
60 V |
3 A |
Quick Connect |
-30 °C (-22 °F) |
2 kA |
Rocker |
Bulk |
1.417 in (36 mm) |
1.142 in (29 mm) |
IP40 |
Trip Free |
1.736 in (44.1 mm) |
CCC; CSA; GB; IEC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
240 V |
60 V |
10 A |
Quick Connect |
-30 °C (-22 °F) |
2 kA |
Rocker |
Bulk |
1.417 in (36 mm) |
1.142 in (29 mm) |
IP40 |
Trip Free |
1.736 in (44.1 mm) |
CCC; CSA; GB; IEC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
72 V |
50 A |
Screw |
-55 °C (-67 °F) |
5 kA |
Push-Pull |
1.22 in (31 mm) |
0.709 in (18 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
1.969 in (50 mm) |
CSA; CUL; UL |
1 |
75 °C (167 °F) |
|||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
20 A |
Screw |
-55 °C (-67 °F) |
2.5 kA |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
0.768 in (19.5 mm) |
0.559 in (14.2 mm) |
IP40; IP00 |
Tease-Free And Trip-Free |
1.22 in (31 mm) |
1 |
125 °C (257 °F) |
||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
5 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
10 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
15 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
15 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
15 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
15 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
30 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
80 V |
1 A |
Screw |
-40 °C (-40 °F) |
1 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
0.745 in (18.92 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
1 A |
Screw |
-40 °C (-40 °F) |
7.5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
0.745 in (18.92 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
20 A |
Screw |
-40 °C (-40 °F) |
3 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL; VDE |
2 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
10 A |
Screw |
-40 °C (-40 °F) |
7.5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
10 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
10 A |
Screw |
-40 °C (-40 °F) |
1 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
0.745 in (18.92 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
80 V |
1 A |
Quick Connect |
-40 °C (-40 °F) |
1 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
0.745 in (18.92 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
10 A |
Screw |
-40 °C (-40 °F) |
7.5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Toggle |
2 in (50.8 mm) |
1.49 in (37.85 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.817 in (46.15 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 V |
12 A |
Solder Hook |
-40 °C (-40 °F) |
1 kA |
Toggle Handle |
1.562 in (39.67 mm) |
1.281 in (32.53 mm) |
Sealed |
Series Trip |
1.78 in (45.21 mm) |
UL |
2 |
100 °C (212 °F) |
||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 V |
3 A |
Solder Hook |
-40 °C (-40 °F) |
1 kA |
Toggle Handle |
1.562 in (39.67 mm) |
1.281 in (32.53 mm) |
Sealed |
Series Trip |
1.78 in (45.21 mm) |
UL |
2 |
100 °C (212 °F) |
||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 V |
3 A |
Solder Hook |
-40 °C (-40 °F) |
1 kA |
Toggle |
1.562 in (39.67 mm) |
1.281 in (32.53 mm) |
Corrosion Resistant; Sealed |
Series Trip |
1.78 in (45.21 mm) |
2 |
100 °C (212 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
10 A |
Screw |
-40 °C (-40 °F) |
1.5 kA |
Toggle Handle |
2 in (50.8 mm) |
2.265 in (57.53 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.73 in (43.94 mm) |
CSA; UL; VDE |
3 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
30 A |
Stud |
-40 °C (-40 °F) |
7.5 kA |
Rocker |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; TUV; UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
100 mA |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
1 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
100 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
80 V |
15 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
15 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
1.515 in (38.48 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
2 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
15 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
1.515 in (38.48 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
2 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
250 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2.563 in (65.1 mm) |
2.265 in (57.53 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
UL |
3 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
225 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2.563 in (65.1 mm) |
2.265 in (57.53 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
UL |
3 |
85 °C (185 °F) |
|||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
15 A |
Stud |
-40 °C (-40 °F) |
3 kA |
Handle |
2.5 in (63.5 mm) |
3.015 in (76.58 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA, UL, VDE |
4 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
70 A |
Stud |
-40 °C (-40 °F) |
Toggle Handle |
2.5 in (63.5 mm) |
2.24 in (56.9 mm) |
Corrosion/Moisture Resistant |
Switch |
1.85 in (47 mm) |
CSA, UL |
3 |
85 °C (185 °F) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.