Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
10 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
2.5 in (63.5 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.85 in (47 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
15 A |
Quick Connect |
1 kA |
Rocker |
0.76 in (19.31 mm) |
0.76 in (19.31 mm) |
Series Trip |
1.535 in (38.99 mm) |
CE; CUL; UL; VDE |
1 |
||||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
410 V |
20 A |
Screw |
-40 °C (-40 °F) |
10 kA |
Handle |
3.672 in (93.26 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.264 in (57.51 mm) |
UL |
2 |
85 °C (185 °F) |
||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
70 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
5.78 in (146.81 mm) |
1.026 in (26.06 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.61 in (66.3 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
70 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
5.78 in (146.81 mm) |
1.026 in (26.06 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.61 in (66.3 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
70 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
5.78 in (146.81 mm) |
1.026 in (26.06 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.61 in (66.3 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 A |
Stud |
-40 °C (-40 °F) |
5 kA |
Handle |
5.78 in (146.81 mm) |
3.138 in (79.7 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.61 in (66.3 mm) |
CSA; UL |
3 |
85 °C (185 °F) |
||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
Panel Mount |
347 V |
40 A |
Screw |
18 kA |
Toggle Handle |
5.5 in (139.7 mm) |
3 in (76.2 mm) |
Manual On/Off |
2.992 in (76 mm) |
CE; CSA; IEC; UL |
3 |
||||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
Panel Mount |
347 V |
50 A |
Screw |
18 kA |
Toggle Handle |
5.5 in (139.7 mm) |
3 in (76.2 mm) |
Manual On/Off |
2.992 in (76 mm) |
CE; CSA; IEC; UL |
3 |
||||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
Panel Mount |
347 V |
70 A |
Screw |
18 kA |
Toggle Handle |
5.5 in (139.7 mm) |
3 in (76.2 mm) |
Manual On/Off |
2.992 in (76 mm) |
CE; CSA; IEC; UL |
3 |
||||||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
4 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Toggle |
2.49 in (63.24 mm) |
0.75 in (19.05 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.859 in (47.22 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
40 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Toggle Handle |
2.49 in (63.24 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.859 in (47.22 mm) |
CSA; UL; VDE |
2 |
85 °C (185 °F) |
||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
2.5 A |
Screw |
-40 °C (-40 °F) |
1 kA |
Toggle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Manual On/Off |
2.256 in (57.3 mm) |
CSA, UL |
2 |
85 °C (185 °F) |
||||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
40 A |
Stud |
5 kA |
Toggle Handle |
2.49 in (63.24 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.859 in (47.22 mm) |
CCC; VDE |
2 |
||||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
65 V |
30 A |
Screw |
-40 °C (-40 °F) |
3 kA |
Sealed Toggle |
1.375 in (34.93 mm) |
0.65 in (16.51 mm) |
Moisture Resistant; IP68; |
Series Trip |
2.158 in (54.81 mm) |
CUL; UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
20 A |
Screw |
-40 °C (-40 °F) |
2 kA |
Sealed Toggle |
1.375 in (34.93 mm) |
1.3 in (33.02 mm) |
Moisture Resistant; IP68; |
Series Trip |
2.158 in (54.81 mm) |
2 |
85 °C (185 °F) |
||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
120 V |
28 V |
3 A |
Screw |
-55 °C (-67 °F) |
3.5 kA |
Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A |
Push Button |
0.781 in (19.84 mm) |
0.593 in (15.06 mm) |
Corrosion Resistant; Moisture Resistant |
0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm) |
Trip |
1.03 in (26.16 mm) |
1 |
121 °C (249.8 °F) |
|||||||||
Carling Technologies |
Equipment Leakage Circuit Breaker |
Panel Mount |
240 V |
50 A |
Stud |
-35 °C (-31 °F) |
3 kA |
Handle |
3.8 in (96.52 mm) |
2.265 in (57.53 mm) |
Series Trip |
2.975 in (75.57 mm) |
CSA; UL |
2 |
66 °C (150.8 °F) |
||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
Panel Mount |
240 V |
48 V |
25 A |
10 kA |
Rated breaking capacity at 48 VDC: 5000 A |
4.05 in (102.87 mm) |
1.5 in (38.1 mm) |
4.05 x 1.5 x 2.95 in (102.87 x 38.1 x 74.93 mm) |
2.95 in (74.93 mm) |
CSA; IEC; UL |
2 |
|||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
2 kA |
6 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm) |
Series Trip |
1.375 in (34.93 mm) |
CSA; UL |
1 |
||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
65 V |
25 A |
Quick Connect |
2.2 s |
Toggle |
Series Trip |
1 |
|||||||||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
2 A |
Quick Connect |
-20 °C (-4 °F) |
1 kA |
ENVIRONMENTAL CHARACTERISTICS: IP40; IP00 |
Push Button |
0.748 in (19 mm) |
0.52 in (13.2 mm) |
Corrosion Resistant; Moisture Resistant |
0.748 x 0.52 x 1.87 in (19 x 13.2 x 47.5 mm) |
Tease-Free And Trip-Free |
1.87 in (47.5 mm) |
CBE; CSA; IEC; UL; VDE |
1 |
60 °C (140 °F) |
Medium |
||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
72 V |
6 A |
Quick Connect |
-20 °C (-4 °F) |
2 kA |
Push Button |
1.921 in (48.8 mm) |
0.323 in (8.2 mm) |
IP00; IP40 |
0.961 x 0.323 x 1.921 in (24.4 x 8.2 x 48.8 mm) |
Trip Free |
0.961 in (24.4 mm) |
CQC; CSA; EN; IEC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
30 V |
150 A |
Screw |
-32 °C (-25.6 °F) |
Lever |
2.89 in (73.41 mm) |
1.9 in (48.26 mm) |
Trip |
1.44 in (36.58 mm) |
SAE; UL |
1 |
82 °C (179.6 °F) |
|||||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
30 A |
Quick Connect |
10 kA |
Toggle Handle |
5.8 in (147.32 mm) |
3.108 in (78.94 mm) |
Moisture Resistant |
Trip Free |
2.61 in (66.29 mm) |
CSA; CUL; UL; VDE |
3 |
|||||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Magnetic Circuit Breaker |
Panel Mount |
250 V |
65 V |
10 A |
Screw |
-30 °C (-22 °F) |
800 A |
Rated breaking capacity at 32 VDC: 2500 A |
Toggle |
1.772 in (45 mm) |
0.492 in (12.5 mm) |
1.772 x 0.492 x 0.122 in (45 x 12.5 x 3.09 mm) |
Manual On/Off |
0.122 in (3.09 mm) |
CSA; GL; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
|
Siemens |
Thermal Circuit Breaker |
Panel Mount |
690 V |
200 A |
Screw |
-25 °C (-13 °F) |
110 kA |
Toggle |
7.1 in (180.34 mm) |
4.1 in (104.14 mm) |
IP40 |
7.1 x 4.1 x 3.4 in (180.34 x 104.14 x 86.36 mm) |
Trip |
3.4 in (86.36 mm) |
3 |
70 °C (158 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
28 V |
30 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
|||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
30 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Tease-Free And Trip-Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
35 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Tease-Free And Trip-Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
40 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Tease-Free And Trip-Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
70 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Tease-Free And Trip-Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
90 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Tease-Free And Trip-Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
30 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Tease-Free And Trip-Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
50 A |
Screw |
-55 °C (-67 °F) |
6 kA |
Push-Pull |
1.26 in (32 mm) |
0.748 in (19 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Tease-Free And Trip-Free |
1.929 in (49 mm) |
CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
200 V |
28 V |
2 A |
Screw |
-55 °C (-67 °F) |
1 kA |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
1.89 in (48 mm) |
0.78 in (19.8 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
1.496 in (38 mm) |
BW; QPL |
3 |
125 °C (257 °F) |
|||||||||
|
Siemens |
Thermal Circuit Breaker |
Panel Mount |
400 V |
2 A |
Screw |
-25 °C (-13 °F) |
10 kA |
5SY |
Sealed Bat |
3.543 in (90 mm) |
0.709 in (18 mm) |
IP20 |
3.543 x 0.709 x 2.756 in (90 x 18 x 70 mm) |
Under Voltage Release |
2.756 in (70 mm) |
CCC; CUL; EN; GOST; IMQ; UL; VDE |
1 |
45 °C (113 °F) |
Standard |
|||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
25 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Toggle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
20 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
30 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 V |
10 A |
Solder Hook |
-40 °C (-40 °F) |
1 kA |
Toggle |
1.562 in (39.67 mm) |
0.656 in (16.66 mm) |
Corrosion Resistant; Sealed |
Trip Free |
1.605 in (40.77 mm) |
1 |
100 °C (212 °F) |
|||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 V |
2.5 A |
Solder Hook |
-40 °C (-40 °F) |
1 kA |
Toggle Handle |
1.562 in (39.67 mm) |
1.281 in (32.53 mm) |
Sealed |
Series Trip |
1.78 in (45.21 mm) |
UL |
2 |
100 °C (212 °F) |
||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 V |
5 A |
Solder Hook |
-40 °C (-40 °F) |
1 kA |
Toggle Handle |
1.562 in (39.67 mm) |
1.281 in (32.53 mm) |
Sealed |
Series Trip |
1.78 in (45.21 mm) |
UL |
2 |
100 °C (212 °F) |
||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
2.5 A |
Solder Hook |
-40 °C (-40 °F) |
1 kA |
Toggle |
1.562 in (39.67 mm) |
1.281 in (32.53 mm) |
Corrosion Resistant; Sealed |
Series Trip |
1.78 in (45.21 mm) |
2 |
100 °C (212 °F) |
||||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
25 A |
Screw |
-40 °C (-40 °F) |
3 kA |
Handle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.73 in (43.94 mm) |
CSA; UL; VDE |
2 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
25 A |
Screw |
-40 °C (-40 °F) |
3 kA |
Handle |
2 in (50.8 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.73 in (43.94 mm) |
CSA; UL; VDE |
2 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
250 mA |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.