Snap On Circuit Breaker 370

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

XT1NU3080AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

80 A

Snap On

18 kA

5.118 in (130 mm)

3 in (76.2 mm)

5.118 x 3 x 2.756 in (130 x 76.2 x 70 mm)

Trip

2.756 in (70 mm)

CSA; UL

3

S202MUC-Z10

Abb

Magnetic Circuit Breaker

DIN Rail Mount

480 V

500 V

10 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle Handle

Bulk

3.465 in (88 mm)

1.378 in (35 mm)

IP20; IP40

Trip

2.717 in (69 mm)

CSA; UL; VDE

2

55 °C (131 °F)

PKZM0-16

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Snap On

-25 °C (-13 °F)

50 kA

Rated breaking capacity max at: 400 VAC

Button

3.638 in (92.4 mm)

1.772 in (45 mm)

IP00; IP20

Trip

2.65 in (67.3 mm)

CE; CSA; IEC/EN; UL

3

55 °C (131 °F)

2CDS251001R0164

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

253 V

72 V

16 A

Snap On

-25 °C (-13 °F)

6 kA

Interrupting current max at 400 VAC: 6000 A

Manual On/Off

3.465 in (88 mm)

0.689 in (17.5 mm)

IP20; IP40

3.465 x 0.689 x 2.717 in (88 x 17.5 x 69 mm)

Trip

2.717 in (69 mm)

CE; EN; IEC; UL

1

55 °C (131 °F)

XT1NU3050AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

50 A

Snap On

18 kA

5.118 in (130 mm)

3 in (76.2 mm)

5.118 x 3 x 2.756 in (130 x 76.2 x 70 mm)

Trip

2.756 in (70 mm)

CSA; UL

3

25218

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

20 A

Snap On

-25 °C (-13 °F)

10 kA

Rated breaking capacity at 250 VDC: 50000 A

Toggle

2.874 in (73 mm)

2.835 in (72 mm)

Environment/Moisture Resistant

2.874 x 2.835 x 3.189 in (73 x 72 x 81 mm)

Trip

3.189 in (81 mm)

EN; IEC

4

60 °C (140 °F)

S201-B6

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

253 V

72 V

6 A

Snap On

-25 °C (-13 °F)

6 kA

Box

3.465 in (88 mm)

0.689 in (17.5 mm)

IP20; IP40

Trip

2.717 in (69 mm)

CE; CSA; EN; IEC; UL

1

55 °C (131 °F)

S201-C16

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

16 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

IP20; IP40

Trip

CSA; IEC; UL

55 °C (131 °F)

XT3SU3150AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

500 V

150 A

Snap On

10 kA

Manual On/Off

CSA; UL

5.118 in (130 mm)

3 in (76.2 mm)

Trip

2.756 in (70 mm)

3

5SV3346-6

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

400 V

63 A

Snap On

-25 °C (-13 °F)

10 kA

Bulk

3.543 in (90 mm)

2.835 in (72 mm)

IP20

Trip

2.756 in (70 mm)

CCC; CE; CEBEC; EAC; IMQ; OVE; VDE

4

45 °C (113 °F)

XT1NU3030AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

500 V

30 A

Snap On

18 kA

Manual On/Off

CSA; UL

5.118 in (130 mm)

3 in (76.2 mm)

Trip

2.756 in (70 mm)

3

XT1NU3040AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

40 A

Snap On

18 kA

5.118 in (130 mm)

3 in (76.2 mm)

5.118 x 3 x 2.756 in (130 x 76.2 x 70 mm)

Trip

2.756 in (70 mm)

CSA; UL

3

420362

Legrand

Thermal Circuit Breaker

DIN Rail Mount

400 V

40 A

Snap On

-25 °C (-13 °F)

50 kA

Handle

Bulk

6.496 in (165 mm)

4.134 in (105 mm)

Trip

3.937 in (100 mm)

IEC

3

70 °C (158 °F)

3RV2011-1DA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

3.2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

24337

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

415 V

16 A

Snap On

-25 °C (-13 °F)

3 kA

Toggle

3.189 in (81 mm)

1.417 in (36 mm)

Trip

2.874 in (73 mm)

2

60 °C (140 °F)

5SY4110-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4110-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

FAZ-C15/2-RT

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-25 °C (-13 °F)

14 kA

Toggle

4.134 in (105 mm)

1.39 in (35.3 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

2

75 °C (167 °F)

XT1NU3100AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

100 A

Snap On

18 kA

5.118 in (130 mm)

3 in (76.2 mm)

5.118 x 3 x 2.756 in (130 x 76.2 x 70 mm)

Trip

2.756 in (70 mm)

CSA; UL

3

5SY4204-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

4 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

5SY6114-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

60 V

14 A

Snap On

-25 °C (-13 °F)

5 kA

Toggle

Bulk

3.543 in (90 mm)

0.709 in (18 mm)

IP20

Trip

2.992 in (76 mm)

CSA; EN; UL

1

55 °C (131 °F)

3RV2011-4AA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2021-4CA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

22 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

FAZ-C5/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

5 A

Snap On

10 kA

Toggle

Manual On/Off

1

3RV2011-0HA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

800 mA

Snap On

-20 °C (-4 °F)

100 kA

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-1JA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

10 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-1KA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

12.5 A

Snap On

-20 °C (-4 °F)

4 kA

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

410151

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

32 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

2.102 in (53.4 mm)

Manual On/Off

3.11 in (79 mm)

IEC

2

70 °C (158 °F)

60140

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

125 V

5 A

Snap On

-30 °C (-22 °F)

6 kA

Rated breaking capacity at 125 VDC: 10000 A, Environmental Characteristics: IP40

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

Environment/Moisture Resistant; IP20

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Trip

4.213 in (107 mm)

CCC; CSA; EN; GB; IEC; UL

2

70 °C (158 °F)

FAZ-C5/1-NA-DC-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

125 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

4.134 in (105 mm)

0.697 in (17.7 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

1

75 °C (167 °F)

243246

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

48 V

6 A

Snap On

-25 °C (-13 °F)

4.5 kA

Handle

Bulk

3.15 in (80 mm)

1.378 in (35 mm)

IP20

Trip

2.579 in (65.5 mm)

EN; IEC

2

75 °C (167 °F)

2D5UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

5SY4363-7

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

63 A

Snap On

10 kA

3.535 in (89.8 mm)

2.079 in (52.8 mm)

IP20

3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; KC; RCM; UL; VDE

3

5SY6203-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

120 V

3 A

Snap On

-25 °C (-13 °F)

5 kA

Toggle Handle

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

2.992 in (76 mm)

CSA; EN; UL

2

55 °C (131 °F)

3RV2011-1FA25

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

FAZ-C16/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

16 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C16/2-NA-DC

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

16 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

4.134 in (105 mm)

1.39 in (35.3 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

2

75 °C (167 °F)

FAZ-C16/2-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

16 A

Snap On

10 kA

Toggle

Manual On/Off

2

3D8UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

8 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

2.067 in (52.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

3

55 °C (131 °F)

5SY4210-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

3RV2011-1EA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

4 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

5SJ4106-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

14 kA

5SJ4106-7HG41

ENVIRONMENTAL CHARACTERISTICS: IP20; IP40; SEALED

4.283 in (108.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

4.283 x 0.693 x 2.748 in (108.8 x 17.6 x 69.8 mm)

Trip

2.748 in (69.8 mm)

CCC; CE; EAC; UL; VDE

1

55 °C (131 °F)

5SY6206-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

120 V

6 A

Snap On

-25 °C (-13 °F)

5 kA

Toggle Handle

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

2.992 in (76 mm)

CSA; EN; UL

2

55 °C (131 °F)

FAZ-C25/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

25 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

3RV2011-0KA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

1.25 A

Snap On

-20 °C (-4 °F)

100 kA

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-1CA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2.5 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-1GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

5SJ4110-7HG40

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

14 kA

5SJ4110-7HG40

ENVIRONMENTAL CHARACTERISTICS: IP20; IP40; SEALED

3.543 in (90 mm)

0.709 in (18 mm)

Environment/Moisture Resistant

3.543 x 0.709 x 2.756 in (90 x 18 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; EAC; UL; VDE

1

55 °C (131 °F)

3RV2011-0GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

630 mA

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.