Snap On Circuit Breaker 370

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

FAZ-D20/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

20 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-B15/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

15 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-D1.5/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-D1.5/3-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-D15/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-D15/3-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-D30/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

30 A

Snap On

10 kA

Toggle

Manual On/Off

2

PKZM4-50

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

50 A

Snap On

-25 °C (-13 °F)

50 kA

Turn Button

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

Trip

6.299 in (160 mm)

CE; CSA; IEC; UL; VDE

3

55 °C (131 °F)

102241

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

3

75 °C (167 °F)

167120

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

40 A

Snap On

3.5 in (88.9 mm)

3 in (76.2 mm)

3.5 x 3 x 1.5 in (88.9 x 76.2 x 38.1 mm)

1.5 in (38.1 mm)

EN; IEC; UL

2

24200

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

6 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

Moisture Resistant

2.874 x 1.417 x 3.189 in (73 x 36 x 81 mm)

Trip

3.189 in (81 mm)

EN; IEC

2

70 °C (158 °F)

FAZ-B40/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

40 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

FAZ-C2/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C4/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

4 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C6/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-D3/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C1/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

1 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C20/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

20 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C20/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

20 A

Snap On

-25 °C (-13 °F)

14 kA

Toggle Handle

4.134 in (105 mm)

2.091 in (53.1 mm)

IP20; IP40

Trip Free

1.772 in (45 mm)

CE; CSA; EN; IEC; UL

3

75 °C (167 °F)

FAZ-C5/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-D6/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-D6/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

10 kA

Toggle

Manual On/Off

2

1019980

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

10 A

Snap On

-35 °C (-31 °F)

5 kA

RATED BREAKING CAPACITY AT 60 VDC: 7500 A

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.37 in (60.2 mm)

CUL; IEC 60947-2; TUV; UL

1

70 °C (158 °F)

167706

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

120 V

40 A

Snap On

Toggle

Trip Free

CSA; CE; CUL; EN; IEC; OVE; UL

4

FAZ-C2/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C8/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

8 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-D10/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

10 A

Snap On

10 kA

FAZ

Toggle

Manual On/Off

1

FAZ-D10/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

10 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-D25/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

25 A

Snap On

-25 °C (-13 °F)

15 kA

3.15 in (80 mm)

1.394 in (35.4 mm)

IP20; IP40

Trip

2.579 in (65.5 mm)

CSA; IEC; UL

2

75 °C (167 °F)

FAZ-D3/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Snap On

-40 °C (-40 °F)

5 kA

Toggle

Bulk

3.15 in (80 mm)

0.697 in (17.7 mm)

IP20

Trip Free

2.362 in (60 mm)

CSA; UL

1

167 °C (332.6 °F)

FAZ-D30/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

30 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-D4/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

4 A

Snap On

10 kA

Toggle

Manual On/Off

1

PKE32/XTU-32

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

32 A

Snap On

-25 °C (-13 °F)

100 kA

Rotary Knob

3.976 in (101 mm)

1.772 in (45 mm)

IP00; IP20

Trip

4.035 in (102.5 mm)

CE; CSA; EN; IEC; UL

3

55 °C (131 °F)

QC1015

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

120 V

15 A

Snap On

10 kA

Toggle

Trip

CSA; UL

1

40 °C (104 °F)

QCF1030

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

30 A

Snap On

10 kA

Toggle

Trip

CSA; UL

1

40 °C (104 °F)

QCF2050

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

50 A

Snap On

10 kA

Toggle Handle

Trip

CSA; UL

2

40 °C (104 °F)

1019986

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

25 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip Free

2.587 in (65.7 mm)

CUL; UL

1

70 °C (158 °F)

167102

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

480 V

40 A

Snap On

-25 °C (-13 °F)

10 kA

Manual On/Off

3.15 in (80 mm)

2.756 in (70 mm)

IP20; IP40

Trip

2.579 in (65.5 mm)

EN; IEC; UL

4

75 °C (167 °F)

FAZ-B1.5/1-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-B10/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

10 A

Snap On

-40 °C (-40 °F)

10 kA

Toggle Handle

3.15 in (80 mm)

2.067 in (52.5 mm)

Corrosion Resistant; IP20; IP40

Trip Free

2.579 in (65.5 mm)

CE; CSA; EN; IEC; UL

3

75 °C (167 °F)

Short

FAZ-B15/1-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C0.5/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

500 mA

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

FAZ-C25/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

25 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-C3/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C40/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

40 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-C50/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

50 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-C6/1-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

FAZ-C6/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.