Snap On Circuit Breaker 370

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

DC2DU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

FAZ-C1.5/2-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C10/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

10 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C15/2-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C15/3-RT

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-25 °C (-13 °F)

14 kA

Toggle

4.134 in (105 mm)

2.091 in (53.1 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

3

75 °C (167 °F)

FAZ-C20/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

20 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

2.362 in (60 mm)

CCC; CSA; UL; VDE

3

75 °C (167 °F)

Short

FAZ-C3/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

3 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

FAZ-C5/1-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

FAZ-D20/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

60 V

20 A

Snap On

-25 °C (-13 °F)

15 kA

Manual On/Off

4.134 in (105 mm)

2.091 in (53.1 mm)

IP20; IP40

Trip

2.972 in (75.5 mm)

CSA; EN; IEC; UL

3

75 °C (167 °F)

GA2-B3-11-663-12-MC

Carling Technologies

Magnetic Circuit Breaker

DIN Rail Mount

80 V

63 A

Snap On

-40 °C (-40 °F)

3 kA

Handle

4.188 in (106.38 mm)

1.376 in (34.95 mm)

Corrosion/Moisture Resistant

Series Trip

2.62 in (66.55 mm)

CSA, UL

2

85 °C (185 °F)

IELR11-1-63-5.00-01-V

Sensata Technologies

Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-40 °C (-40 °F)

2 kA

Toggle Handle

3.622 in (92 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant; IP00; IP40

Series Trip

1.929 in (49 mm)

CSA; UL; VDE

2

85 °C (185 °F)

M9F42110

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

415 V

60 V

10 A

Snap On

-30 °C (-22 °F)

3 kA

Toggle

Bulk

4.055 in (103 mm)

0.709 in (18 mm)

IP20; IP40

Trip

2.835 in (72 mm)

CCC; CSA; EN; GB; IEC; UL

1

70 °C (158 °F)

NC1V-1111-20AA

Idec

Magnetic Circuit Breaker

DIN Rail And Panel Mount

250 V

65 V

20 A

Snap On

-10 °C (14 °F)

2.5 kA

Toggle

3.102 in (78.8 mm)

0.689 in (17.5 mm)

Manual On/Off

2.598 in (66 mm)

CCC; CE; CSA; PSE; TUV; UL

1

60 °C (140 °F)

NC1V-1111F-20AA

Idec

Magnetic Circuit Breaker

DIN Rail Mount

250 V

65 V

20 A

Snap On

-10 °C (14 °F)

2.5 kA

Toggle

2.811 in (71.4 mm)

0.689 in (17.5 mm)

IP20

Series Trip

2.598 in (66 mm)

CCC; CE; CSA; PSE; TUV; UL

1

60 °C (140 °F)

NC1V-3113-1AA

Idec

Magnetic Circuit Breaker

DIN Rail Mount

250 V

1 A

Snap On

-10 °C (14 °F)

2.5 kA

Toggle Handle

2.811 in (71.4 mm)

2.067 in (52.5 mm)

IP20

Series Trip

2.598 in (66 mm)

CCC; CE; CSA; PSE; TUV; UL

3

60 °C (140 °F)

PKZM0-25

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Rated breaking capacity max at: 400 VAC

Button

3.638 in (92.4 mm)

1.772 in (45 mm)

IP00; IP20

Trip

2.65 in (67.3 mm)

CE; CSA; IEC/EN; UL

3

55 °C (131 °F)

PKZM0-2,5

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

690 V

2.5 A

Snap On

-25 °C (-13 °F)

150 kA

Rated breaking capacity at 400 VAC

Turn Button

3.638 in (92.4 mm)

1.772 in (45 mm)

IP00; IP20

3.638 x 1.772 x 2.65 in (92.4 x 45 x 67.3 mm)

Trip

2.65 in (67.3 mm)

CE; CSA; EN; IEC; UL

3

55 °C (131 °F)

S201U-K20

Abb

Thermal Circuit Breaker

DIN Rail Mount

230 V

20 A

Snap On

-25 °C (-13 °F)

10 kA

Manual On/Off

2.795 in (71 mm)

0.689 in (17.5 mm)

IP20

2.795 x 0.689 x 3.622 in (71 x 17.5 x 92 mm)

3.622 in (92 mm)

CCC; CSA; IEC; UL; VDE

1

55 °C (131 °F)

140M-C2E-B25

Rockwell Automation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

600 V

600 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Manual On/Off

3.622 in (92 mm)

1.772 in (45 mm)

Moisture Resistant; IP2X

Shunt Trip

2.618 in (66.5 mm)

CCC; CE; CSA; CUL; EN; IEC; UL

3

60 °C (140 °F)

Instantaneous

243308

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

48 V

250 mA

Snap On

-25 °C (-13 °F)

4.5 kA

Handle

Bulk

3.15 in (80 mm)

2.067 in (52.5 mm)

IP20

Trip

2.579 in (65.5 mm)

EN; IEC

3

75 °C (167 °F)

2DU10L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3BU1R

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

3.366 in (85.5 mm)

2.067 in (52.5 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

3

60 °C (140 °F)

3CU25R

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

25 A

Snap On

-20 °C (-4 °F)

5 kA

Toggle Handle

Bulk

3.366 in (85.5 mm)

2.067 in (52.5 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

3

60 °C (140 °F)

409802

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

100 A

Snap On

-25 °C (-13 °F)

25 kA

Toggle Handle

Bulk

4.205 in (106.8 mm)

4.106 in (104.3 mm)

Manual On/Off

3.11 in (79 mm)

IEC

4

70 °C (158 °F)

4230-T130-K0CE-1A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle Handle

3.228 in (82 mm)

2.083 in (52.9 mm)

Corrosion Resistant; IP20

Trip Free

2.37 in (60.2 mm)

UL; TUV

3

70 °C (158 °F)

5SY4120-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

20 A

Snap On

-25 °C (-13 °F)

5 kA

3.535 in (89.8 mm)

0.693 in (17.6 mm)

IP20; Sealed

3.535 x 0.693 x 3.008 in (89.8 x 17.6 x 76.4 mm)

Trip

3.008 in (76.4 mm)

CCC; CE; IMQ; RCM; UL; VDE

1

55 °C (131 °F)

5SY4302-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

2 A

Snap On

10 kA

3.535 in (89.8 mm)

2.079 in (52.8 mm)

IP20

3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

3

60137

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

72 V

2 A

Snap On

-30 °C (-22 °F)

6 kA

Interrupting current max at 125 VDC: 10000 A

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

IP20; IP40

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Trip

4.213 in (107 mm)

CCC; CSA; EN/IEC; GB; UL

2

70 °C (158 °F)

A9N18369

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

375 V

125 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

Bulk

3.189 in (81 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

3

70 °C (158 °F)

A9N18388

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

375 V

100 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

Bulk

3.189 in (81 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

3

70 °C (158 °F)

A9N18469

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

375 V

100 A

Snap On

-30 °C (-22 °F)

10 kA

Rated breaking capacity at 375 VDC: 15000 A

Toggle Handle

Bulk

3.189 in (81 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

3

60 °C (140 °F)

ESX10-TB-101-DC24V-3A-E

E-t-a Elektrotechnische Apparate

Equipment Leakage Circuit Breaker

DIN Rail Mount

24 V

3 A

Snap On

-25 °C (-13 °F)

Reset Button

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

Trip

3.268 in (83 mm)

ATEX; CSA; CUL; DNV; IEC; TUV; UKCA; UL

1

60 °C (140 °F)

FAZ-C1.5/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C10/2-RT

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

4.134 in (105 mm)

1.39 in (35.3 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

2

75 °C (167 °F)

FAZ-C15/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C2/1-RT-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

4.134 in (105 mm)

0.697 in (17.7 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

1

75 °C (167 °F)

FAZ-D10/2

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

10 A

Snap On

-40 °C (-40 °F)

5 kA

Toggle

3.15 in (80 mm)

1.394 in (35.4 mm)

IP20

Trip Free

2.362 in (60 mm)

CSA; UL

2

167 °C (332.6 °F)

3D2UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

2 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

3

55 °C (131 °F)

5SY4106-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4106-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

CCP2R-2-30CC

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

600 V

125 V

30 A

Snap On

200 kA

Toggle Handle

3.7 in (93.98 mm)

0.3 in (7.62 mm)

1.9 in (48.26 mm)

UL

2

FAZ-C6/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-C3/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

10 kA

Toggle

Manual On/Off

2

CCP2SL-2-30CC

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

600 V

125 V

30 A

Snap On

200 kA

Toggle Handle

3.7 in (93.98 mm)

0.3 in (7.62 mm)

Manual On/Off

1.9 in (48.26 mm)

2

24452

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

125 V

20 A

Snap On

-30 °C (-22 °F)

5 kA

Toggle

Bulk

3.189 in (81 mm)

1.417 in (36 mm)

IP20; IP40

Trip

2.874 in (73 mm)

CCC; CSA; IEC; UL

2

70 °C (158 °F)

FAZ-C1.5/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C15/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-B6/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-C20/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

20 A

Snap On

10 kA

Toggle

Manual On/Off

1

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.