200 A Fuses 347

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LPJ-200SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.63 in (41.4 mm)

J

600 V

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

LPJ-200SPI

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

1.63 in (41.4 mm)

J

600 V

Indicator

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

AJT200

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

1.614 in (41 mm)

Indicator

1.614 x 2.992 in (41 x 76 mm)

5.748 in (146 mm)

Time Delay

AJT200N

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

200 A

Tab/Blade

200 kA

1.614 in (41 mm)

5.748 in (146 mm)

CSA; IEC; UL

Time Delay

AJT200/400

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

200 A

Tab/Blade

200 kA

2.126 in (54 mm)

J

600 V

7.126 in (181 mm)

IEC, UL

Time Lag

AJT200EI

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

Indicator

3.236 in (82.2 mm)

3.22 in (81.8 mm)

UL

Time Delay

SP/LPJ-200SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

Silver

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.63 in (41.4 mm)

e4

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

FLSR200.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

170M3744

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

1.3 KV

200 A

Tab/Blade

5.15 kJ

100 kA

Rated Breaking Capacity at 1300 VDC: 100000 A

Box

6.142 in (156 mm)

1.772 in (45 mm)

Indicator

6.142 x 1.772 x 1.772 in (156 x 45 x 45 mm)

1.772 in (45 mm)

CE; IEC; UL

170M1759

Eaton Corporation

Electric Fuse

Inline/Holder

800 V

200 A

Tab/Blade

4.35 kJ

50 kA

2.126 in (54 mm)

1.429 in (36.3 mm)

0.945 in (24 mm)

UL

FWH-200B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

200 A

Tab/Blade

1.9 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

1.156 in (29.36 mm)

1.156 x 1.836 in (29.36 x 46.63 mm)

1.836 in (46.63 mm)

CE; CSA; UL

0JTD200.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

200 A

Tab/Blade

159 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

600 V

Indicator

3 in (76.2 mm)

CSA; UL

Time Delay

3NE3225

Siemens

Electric Fuse

Inline/Holder

1 KV

200 A

Tab/Blade

-20 °C (-4 °F)

100 kA

2.874 in (73 mm)

2.047 in (52 mm)

Indicator

2.874 x 2.047 x 2.047 in (73 x 52 x 52 mm)

2.047 in (52 mm)

CCC; CE; UL

50 °C (122 °F)

FLSR200.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

Indicator

9.626 in (244.5 mm)

CSA; UL

Time Delay

0JTD200.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

200 A

Tab/Blade

159 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

600 V

3 in (76.2 mm)

CSA; UL

Time Delay

0298200ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

204 kJ

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0298200.ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

204 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

A4J200

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.614 in (41 mm)

1.614 x 2.992 in (41 x 76 mm)

2.992 in (76 mm)

CSA; UL

Fast

MEV100A200-4

Mersen S A

Electric Fuse

Inline/Holder

1 KV

200 A

Tab/Blade

100 kA

80 ms

Bulk

1.22 in (31 mm)

2.874 in (73 mm)

IATF 16949; UL

MEV100A200-4Y

Mersen S A

Electric Fuse

Inline/Holder

1 KV

200 A

Tab/Blade

100 kA

80 ms

Bulk

1.22 in (31 mm)

2.874 in (73 mm)

IATF 16949; UL

0498200.M

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

125 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

JLLS200.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.079 in (27.4 mm)

600 V

1.657 in (42.1 mm)

CE; CSA; UL

Fast

JLLS200

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

1.063 x 1.657 in (27 x 42.1 mm)

1.657 in (42.1 mm)

CSA; UL

Fast

JLLS200.XXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.079 in (27.4 mm)

600 V

1.657 in (42.1 mm)

CE; CSA; UL

Fast

170M4458

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

200 A

Tab/Blade

1.65 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

CGL-200

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

200 A

Tab/Blade

200 kA

1.5 in (38.1 mm)

1.5 x 3 in (38.1 x 76.2 mm)

3 in (76.2 mm)

CSA

153.0020.6202

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

126 kJ

-40 °C (-40 °F)

1.5 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.315 in (8 mm)

CUL; ISO; UL

125 °C (257 °F)

PSR030FL0200Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

200 A

Threaded

3.012 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

V300697

Mersen S A

Electric Fuse

Inline/Holder

690 V

200 A

Tab/Blade

2.6 kJ

200 kA

Bulk

1.874 in (47.6 mm)

2.008 in (51 mm)

Indicator

2.224 in (56.5 mm)

CCC; CE; CSA; EAC; IEC; UL; VDE

Ultra Fast

0498200.MXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

125 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

170M4489

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

200 A

End Cap

3.8 kJ

100 kA

2.913 in (74 mm)

2.087 in (53 mm)

Indicator

2.913 x 2.087 x 2.087 in (74 x 53 x 53 mm)

2.087 in (53 mm)

CE; IEC; UL

DEO200

Eaton Corporation

Electric Fuse

Inline/Holder

415 V

200 A

Tab/Blade

120 kJ

Box

1.22 in (31 mm)

1.22 x 1.85 in (31 x 47 mm)

1.85 in (47 mm)

BS 88; IEC

FWP-200A

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

200 A

Tab/Blade

5.5 kJ

50 kA

Box

1.5 in (38.1 mm)

1.5 x 2.84 in (38.1 x 72.14 mm)

2.84 in (72.136 mm)

CE; CSA; UL

JKS-200

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

200 A

Tab/Blade

200 kA

1.63 in (41.4 mm)

J

600 V

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Fast

SPFJ200.XXL

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

200 A

Tab/Blade

79.642 kJ

20 kA

10 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Midget

3.012 in (76.5 mm)

CE; IEC; UL; VDE

ANL-200

Eaton Corporation

Electric Fuse

Inline/Holder

80 V

200 A

End Cap

2.7 kA

3.189 in (81 mm)

Indicator

3.189 x 0.874 in (81 x 22.2 mm)

0.874 in (22.2 mm)

CSA; UL

Time Delay

NON-200

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

200 A

Tab/Blade

10 kA

Rated Breaking Capacity at 125 VDC: 10000 A

Box

1.56 in (39.62 mm)

H

250 V

1.56 x 7.13 in (39.62 x 181.1 mm)

7.13 in (181.1 mm)

CE; CSA; UL

SPFJ200.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

200 A

Tab/Blade

108 kJ

200 kA

10 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Midget

1.5 x 3 in (38.1 x 76.2 mm)

3.012 in (76.5 mm)

CE; IEC; UL; VDE

JJN-200

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

160 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 160 VDC: 20000 A

Box

0.874 in (22.2 mm)

0.874 x 0.843 in (22.2 x 21.4 mm)

0.843 in (21.4 mm)

CE; CSA; UL

Very Fast

170M1420

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

200 A

Tab/Blade

4.2 kJ

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

Indicator

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

0498200.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

125 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

0LDC200.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

200 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE, UL

Fast

142.5395.6202

Littelfuse

Electric Fuse

Inline/Holder

58 V

200 A

Tab/Blade

288 kJ

-40 °C (-40 °F)

1 kA

100 ms

1.142 in (29 mm)

58 V

1.142 x 0.74 x 0.366 in (29 x 18.8 x 9.3 mm)

0.366 in (9.3 mm)

UL

125 °C (257 °F)

Slow

170M2667

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

200 A

Tab/Blade

3.4 kJ

200 kA

Box

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm)

2.008 in (51 mm)

CE; CSA; DIN 43653; IEC; UL

0CNL200.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

200 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

UL

Fast

170M3465

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

200 A

Tab/Blade

2.2 kJ

200 kA

Box

1.772 in (45 mm)

1.772 in (45 mm)

Indicator

1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

JLLN200.X

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

300 V

2.437 in (61.9 mm)

CE; CSA; CUL; UL

Fast

0998200.UX-2M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

200 A

Tab/Blade

123.6 kJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.