Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.843 in (46.8 mm) |
Indicator |
1.843 x 9.626 in (46.8 x 244.5 mm) |
9.626 in (244.5 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
200 A |
End Cap |
80 kA |
Hermitically Sealed Part Number |
6.38 in (162.05 mm) |
6.38 x 10.875 in (162.05 x 276.23 mm) |
10.875 in (276.23 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
200 A |
Tab/Blade |
125 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
200 A |
Tab/Blade |
3.012 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
200 A |
Tab/Blade |
204 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
1.535 in (39 mm) |
7.126 in (181 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
200 A |
Tab/Blade |
245.8 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
1.15 in (29.2 mm) |
0.75 in (19.05 mm) |
e3 |
32 V |
Mega |
0.381 in (9.69 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
200 A |
Tab/Blade |
760 A |
Rated Breaking Capacity=760A-80000A |
3 in (76.2 mm) |
Indicator |
3 x 18 in (76.2 x 457.2 mm) |
18 in (457.2 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 250 VDC: 20000 A |
1.22 in (31 mm) |
1.22 x 1.626 in (31 x 41.3 mm) |
1.626 in (41.3 mm) |
CE; CSA; UL |
Very Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
48 V |
200 A |
Tab/Blade |
2.5 kA |
3.181 in (80.8 mm) |
48 V |
3.18 in (80.77 mm) |
UL |
Very Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
150 V |
200 A |
Tab/Blade |
9 J |
100 kA |
Rated Breaking Capacity at 150 VDC: 100000 A |
1.13 in (28.7 mm) |
1.13 x 1.161 in (28.7 x 29.5 mm) |
1.161 in (29.5 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.063 in (27 mm) |
300 V |
2.437 in (61.9 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
200 A |
Tab/Blade |
2.5 kA |
3.181 in (80.8 mm) |
3.18 x 2.43 in (80.77 x 61.72 mm) |
UL |
Fast |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
200 A |
Tab/Blade |
10 kA |
1.06 in (26.92 mm) |
1 x 3.579 in (25.4 x 90.91 mm) |
4.72 in (119.88 mm) |
Time Delay |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
200 A |
End Cap |
80 kA |
150E-2C-8.25 |
6.378 in (162 mm) |
6.378 x 15.874 in (162 x 403.2 mm) |
15.874 in (403.2 mm) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
200 A |
Tab/Blade |
111.7 kJ |
-40 °C (-40 °F) |
2.5 kA |
70 ms |
0.63 in (16 mm) |
0.496 in (12.6 mm) |
0.323 in (8.2 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
200 A |
Tab/Blade |
42 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.362 in (60 mm) |
NH |
2.362 in (60 mm) |
UL |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
200 A |
Tab/Blade |
200 kA |
KLSR |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.843 in (46.8 mm) |
9.626 in (244.5 mm) |
CSA; UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
80 V |
200 A |
Tab/Blade |
2.7 kA |
3.181 in (80.8 mm) |
3.18 in (80.77 mm) |
CUL; UL |
Very Fast |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
200 A |
End Cap |
760 A |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 10.875 in (76.2 x 276.23 mm) |
10.875 in (276.23 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
200 A |
Tab/Blade |
260 kJ |
50 kA |
1.563 in (39.7 mm) |
1.563 x 4.378 in (39.7 x 111.2 mm) |
7.126 in (181 mm) |
CE; CSA; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
80 V |
200 A |
Wraparound |
165.3 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.232 in (31.3 mm) |
0.984 in (25 mm) |
0.63 in (16 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
200 A |
Tab/Blade |
193 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
200 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.559 in (65 mm) |
1.575 in (40 mm) |
Indicator |
2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm) |
2.835 in (72 mm) |
VDE |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
200 A |
End Cap |
760 A |
LCL |
Rated Breaking Capacity=760A-80000A |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
200 A |
End Cap |
60 kA |
200E-3C-15.5 |
9.748 in (247.6 mm) |
9.748 x 18.874 in (247.6 x 479.4 mm) |
18.874 in (479.4 mm) |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
200 A |
End Cap |
80 kA |
LCY |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
200 A |
End Cap |
760 A |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 17.875 in (76.2 x 454.03 mm) |
17.875 in (454.03 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
200 A |
End Cap |
760 A |
Part Number With Hookeye Attachment |
3 in (76.2 mm) |
3 x 10.875 in (76.2 x 276.23 mm) |
10.875 in (276.23 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
200 A |
End Cap |
60 kA |
Hermitically Sealed Part Number |
6.38 in (162.05 mm) |
6.38 x 21.915 in (162.05 x 556.63 mm) |
21.915 in (556.63 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
200 A |
End Cap |
80 kA |
LCZ |
6.38 in (162.05 mm) |
6.38 x 17.87 in (162.05 x 453.89 mm) |
17.87 in (453.89 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
200 A |
Tab/Blade |
123.6 kJ |
-40 °C (-40 °F) |
Tin |
2.5 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
e3 |
70 V |
Mega |
0.39 in (9.9 mm) |
ISO |
125 °C (257 °F) |
|||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
200 A |
End Cap |
80 kA |
LDZ |
Hermitically Sealed Part Number |
6.38 in (162.05 mm) |
6.38 x 15.875 in (162.05 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
120 V |
200 A |
Tab/Blade |
129.6 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.594 in (40.5 mm) |
Indicator |
1.594 x 7.126 in (40.5 x 181 mm) |
7.126 in (181 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
200 A |
Threaded |
4.177 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.913 in (74 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
200 A |
Tab/Blade |
760 A |
Rated Breaking Capacity=760A-80000A |
3 in (76.2 mm) |
Indicator |
3 x 18 in (76.2 x 457.2 mm) |
18 in (457.2 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
200 A |
Tab/Blade |
60 kA |
11.56 in (293.62 mm) |
11.56 x 19.1 in (293.62 x 485.14 mm) |
19.1 in (485.14 mm) |
Medium |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.594 in (40.5 mm) |
1.594 x 7.126 in (40.5 x 181 mm) |
7.126 in (181 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
200 A |
Tab/Blade |
125 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
200 A |
Tab/Blade |
-40 °C (-40 °F) |
1.2 kA |
200 ms |
Bulk |
3.228 in (82 mm) |
0.787 in (20 mm) |
0.031 in (0.8 mm) |
125 °C (257 °F) |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
200 A |
Tab/Blade |
200 kA |
KLB |
Rated Breaking Capacity at 250 VDC: 20000 A |
1.22 in (31 mm) |
1.22 x 1.626 in (31 x 41.3 mm) |
1.626 in (41.3 mm) |
CSA; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
200 A |
Tab/Blade |
100 kA |
Bulk |
1 in (25.4 mm) |
1 x 1.157 in (25.4 x 29.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
120 V |
200 A |
Tab/Blade |
129.6 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
200 A |
Tab/Blade |
3.012 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
200 A |
Tab/Blade |
123.6 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
200 A |
Tab/Blade |
204 kJ |
-40 °C (-40 °F) |
Silver |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
e4 |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
200 A |
Tab/Blade |
22 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.008 in (51 mm) |
GPV |
1.5 KV |
NH |
2.008 in (51 mm) |
UL |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.