200 A Fuses 347

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

L60S200

Littelfuse

Electric Fuse

Inline/Holder

600 V

200 A

Tab/Blade

-55 °C (-67 °F)

200 kA

1.311 in (33.3 mm)

1.311 x 2.906 in (33.3 x 73.8 mm)

2.906 in (73.8 mm)

CSA; UL

125 °C (257 °F)

Very Fast

RLN200

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 A

Tab/Blade

10 kA

1.563 in (39.7 mm)

7.126 in (181 mm)

CE; CSA; UL

200E2C5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

200 A

End Cap

80 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 15.875 in (162.05 x 403.23 mm)

15.874 in (403.2 mm)

Medium

NH1G200

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

200 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.559 in (65 mm)

1.575 in (40 mm)

Indicator

2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm)

2.835 in (72 mm)

VDE

IDSR200ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

200 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

0498200.M-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

125 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

LA070URD30LI0200

Littelfuse

Electric Fuse

Inline/Holder

700 V

200 A

Tab/Blade

3 J

200 kA

1.575 in (40 mm)

1.575 in (40 mm)

Indicator

1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

IDSR200.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

3298200.ZXM10

Littelfuse

Electric Fuse

Panel Mount

32 V

200 A

Wraparound

126.4 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.232 in (31.3 mm)

0.984 in (25 mm)

0.63 in (16 mm)

125 °C (257 °F)

Time Delay

142.7010.6202

Littelfuse

Electric Fuse

Inline/Holder

58 V

200 A

Tab/Blade

126 kJ

-40 °C (-40 °F)

Tin

1 kA

100 ms

126000

0.63 in (16 mm)

0.472 in (12 mm)

e3

58 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

153.7000.6201

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

126 kJ

Tin

1.5 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.