300 V Fuses 1,812

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LGD012

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

12 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

Indicator

CSA; UL

Time Delay

FLQ1.12

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.12 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

CCMR1.25

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.25 A

End Cap

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

JLLS070

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 1.642 in (20.6 x 41.7 mm)

1.642 in (41.7 mm)

CSA; UL

Fast

FLSR3.50

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.5 A

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

CSA; UL

Time Delay

0FLQ.125T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

125 mA

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

JLLS110

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

1.063 x 1.657 in (27 x 42.1 mm)

1.657 in (42.1 mm)

CSA; UL

Fast

FLSR.250ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

0FLQ01.5HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.5 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LLSRK.100ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LLSRK008

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

JTD070

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.126 in (28.6 mm)

2.626 in (66.7 mm)

CSA; UL

Time Delay

LGD3

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

CSA; IEC; UL

Time Delay

KLDR04.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4.5 A

End Cap

83.89 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLSR.150

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 mA

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

Time Delay

80711250440

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

1.25 A

Wire

3 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; PSE; UL

125 °C (257 °F)

Time Lag

LLSRK008ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

JTD03.2

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.2 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

FLSR015

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

15 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

Time Delay

CCMR1.25TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

JLLS300.XXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.594 in (40.5 mm)

600 V

1.713 in (43.5 mm)

CE; CSA; UL

Fast

LLSRK2.50

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

JTD21/4ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

7945894964

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

7 A

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

LGD007

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

7 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

Indicator

CSA; UL

Time Delay

0FLQ.300T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

300 mA

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LLSRK.300ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LLSRK003ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LA30QS800-4IL

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

800 A

Tab/Blade

330 J

200 kA

LA30

Rated Breaking Capacity at 300 VDC: 20000 A

UL

Very Fast

FLSR400

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

400 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

FLSR001

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLDR008.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

8 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LA30QS35-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

35 A

Tab/Blade

900 mJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.72 in (18.3 mm)

0.72 x 1.63 in (18.3 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

LLSRK050ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

50 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

Indicator

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

KLDR003.HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

LA30QS550-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

550 A

Tab/Blade

190 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.579 in (38.1 x 40.1 mm)

1.579 in (40.1 mm)

UL

Very Fast

KLSR035

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

KLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

5.5 in (139.7 mm)

CSA; UL

Fast

KLDR010.H

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

10 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLSR0.5ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

500 mA

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

JLLS020.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

600 V

1.5 in (38.1 mm)

CE; CSA; UL

Fast

KLLU601.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

601 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

CCMR009.HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

9 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLSR025ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

70G

Littelfuse

Electric Fuse

Inline/Holder

125 V

300 V

500 mA

End Cap

1 kA

70

Rated Breaking Capacity at 300 VDC: 1000 A

Alarm

UL

7945894967

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.5 A

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

7945816043

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2.5 A

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

KLKR004.

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

FLSR040

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

40 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.