300 V Fuses 1,812

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

KLKR8

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

LGD7

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

7 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

CSA; IEC; UL

Time Delay

KLKR.100T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 mA

Tab/Blade

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

JLLS070.VXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.827 in (21 mm)

600 V

1.626 in (41.3 mm)

CE; CSA; UL

Fast

JLLS600.XXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.063 in (52.4 mm)

600 V

1.764 in (44.8 mm)

CE; CSA; UL

Fast

0FLQ007.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

7 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

JTD003ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

820 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

LA30QS1000-128

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

1 kA

End Cap

460 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3 in (76.2 mm)

3 x 2.339 in (76.2 x 59.4 mm)

2.339 in (59.4 mm)

UL

Very Fast

KLKR008.

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

8 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

FLSR350ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; QPL; UL

Time Delay

LA30QS700-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

700 A

Tab/Blade

260 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.579 in (38.1 x 40.1 mm)

1.579 in (40.1 mm)

UL

Very Fast

FLQ002R

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

KLKR025.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

25 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

FLQ.250

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

250 mA

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLSR045

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

45 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

LLSRK4.50

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3.094 in (78.6 mm)

3.094 x 13.374 in (78.6 x 339.7 mm)

13.374 in (339.7 mm)

CSA; UL

Time Delay

KLDR04.5TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4.5 A

End Cap

83.89 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

70C

Littelfuse

Electric Fuse

Inline/Holder

125 V

300 V

3 A

End Cap

1 kA

70

Rated Breaking Capacity at 300 VDC: 1000 A

Alarm

UL

KLDR007.H

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

7 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0FLQ007.HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

7 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LA30QS2000-128IL

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

2 kA

End Cap

2.6 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3.5 in (88.9 mm)

3.5 x 2.339 in (88.9 x 59.4 mm)

2.339 in (59.4 mm)

UL

Very Fast

KLKR03.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.5 A

Tab/Blade

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

LLSRK.300

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLSR012

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

12 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLDR05.6

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5.6 A

End Cap

87.66 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

JTD70ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1 in (25.4 mm)

Indicator

2.626 in (66.7 mm)

CSA; UL

Time Delay

KLDR07.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

7.5 A

End Cap

321.8 J

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

LLSRK009ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

9 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

0FLQ.100T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

100 mA

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLQ.300

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

300 mA

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLSR.600ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

600 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

KLKR.200T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

200 mA

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

0FLQ6.25T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

6.25 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LLSRK002

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

CCMR.800HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

800 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

LLSRK.500ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

500 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLDR.150TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 mA

End Cap

1.6 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLSR400ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

400 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; QPL; UL

Time Delay

LLSRK2.25ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKR002.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

CCMR01.6

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0FLQ1.25HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.25 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LGD015

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

15 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

Indicator

CSA; UL

Time Delay

80708000440

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

800 mA

Wire

12.48 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; UL

125 °C (257 °F)

Time Lag

80711250000

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

1.25 A

Wire

3 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; PSE; UL

125 °C (257 °F)

Time Lag

CCMR.250HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLQ004R

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

4 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

KLDR.125T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

125 mA

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.