300 V Fuses 1,812

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

KLDR.300T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 mA

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLQ02.5

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2.5 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

JTD01.8

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

7945894959

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1 A

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

7945816023

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

400 mA

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

KLKR025

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

25 A

Tab/Blade

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

KLDR020

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

123.8 J

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLSR07.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

75 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

KLDR01.8H

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.8 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LLSRK400

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

400 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

FLQ1.12T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.12 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

0FLQ.150HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

150 mA

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

JTD10ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

10 A

End Cap

1.69 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

JTD04.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4.5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

FLSR1.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.8 A

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

CCMR02.5HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.5 A

End Cap

192 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

LLSRK.100

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLDR.150

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 mA

End Cap

1.6 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0FLQ05.6T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

5.6 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

KLDR03.2HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.2 A

End Cap

37.92 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLKR003.

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

KLDR009.HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

9 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

JLLS600

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.063 in (52.4 mm)

2.063 x 1.764 in (52.4 x 44.8 mm)

1.764 in (44.8 mm)

CSA; UL

Fast

KLKR.300T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 mA

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

80711000440

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

1 A

Wire

20 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; PSE; UL

125 °C (257 °F)

Time Lag

LLSRK6.25ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLQ014.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

14 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

LA30QS300-4TI

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

300 A

Tab/Blade

37 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.5 in (38.1 mm)

Indicator

1.5 x 1.579 in (38.1 x 40.1 mm)

1.579 in (40.1 mm)

UL

Very Fast

0JTD060.TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

60 A

End Cap

10.45 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.063 in (27 mm)

600 V

Indicator

2.374 in (60.3 mm)

CSA; UL

Time Delay

7945894951

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

187.5 mA

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

FLSR3.2ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.2 A

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LA30QS250-4TI

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

250 A

Tab/Blade

25 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.5 in (38.1 mm)

Indicator

1.5 x 1.579 in (38.1 x 40.1 mm)

1.579 in (40.1 mm)

UL

Very Fast

7945894972

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

15 A

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

FLQ002.

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2 A

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

CCMR002.HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0FLQ020.HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

20 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLQ008R

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

8 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLQ030

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

30 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLSR1.25ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

JTD12ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

12 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

KLDR1.12

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.12 A

End Cap

504.9 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLQ001.

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1 A

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

JLLS015.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

15 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

600 V

1.5 in (38.1 mm)

CE; CSA; UL

Fast

FLSR500.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

500 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

3.043 in (77.3 mm)

13.374 in (339.7 mm)

CSA; UL

Time Delay

CCMR008

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

8 A

End Cap

431 J

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLKR03.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.5 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

LLSRK05.6

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5.6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLDR001.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.