300 V Fuses 1,812

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LA30QS600-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

600 A

Tab/Blade

230 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.579 in (38.1 x 40.1 mm)

1.579 in (40.1 mm)

UL

Very Fast

LA30QS130-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

130 A

Tab/Blade

6.3 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.22 in (31 mm)

1.22 x 1.63 in (31 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

LLSRK17.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

17.5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLSR60ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

60 A

End Cap

200 kA

1.063 in (27 mm)

Indicator

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

FLSR5ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5 A

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLSR3.50ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; QPL; UL

Time Delay

KLLU1500.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.5 kA

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3 in (76.2 mm)

3.752 in (95.3 mm)

CE; CSA; UL

Time Delay

36908000440

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

800 mA

Pin Wire

5.12 J

-40 °C (-40 °F)

Tin

50 A

20 s

3.8

Bulk

0.335 in (8.5 mm)

0.157 in (4 mm)

e3

300 V

TE5

0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm)

0.315 in (8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

KLDR2.25

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.25 A

End Cap

1.126 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLQ2

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2 A

End Cap

10 kA

12 s

Pre Arcing Time: Open within 12 s at 200% Rated Current

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Slow

CCMR6.25TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6.25 A

End Cap

797 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

JTD006ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

JLLS020

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 1.5 in (14.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

FLSR250

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

CCMR003

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

286 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLSR030ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

30 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

FLQ1.25T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.25 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

FLSR0.25ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 mA

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLDR01.8

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.8 A

End Cap

996.4 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLQ04.5

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

4.5 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

JLLS1000.XXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 kA

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.626 in (66.7 mm)

600 V

5.272 in (133.9 mm)

CE; CUL; UL

Fast

JLLS300

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.594 in (40.5 mm)

1.594 x 1.72 in (40.5 x 43.7 mm)

1.72 in (43.7 mm)

CSA; UL

Fast

JTD040ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

40 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.063 in (27 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.374 in (60.3 mm)

CSA; UL

Time Delay

FLSR002.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKR.500

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

500 mA

Tab/Blade

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

JLLS900.XXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

900 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.626 in (66.7 mm)

600 V

2.303 in (58.5 mm)

CE; CSA; UL

Fast

7945894958

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

800 mA

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

FLSR4ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLQ01.5T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.5 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

JTD03.2ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.2 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

FLQ.187R

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

187.5 mA

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

KLDR.500HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

500 mA

End Cap

87.7 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

LLSRK001

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLSR005ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

FLSR5.60

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5.6 A

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

CSA; UL

Time Delay

FLSR070.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.283 in (32.6 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

CCMR.300HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

LLSRK225

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

LA30QS100-4TI

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

100 A

Tab/Blade

4.1 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.22 in (31 mm)

Indicator

1.22 x 1.63 in (31 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

LGD050

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

50 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

Indicator

CSA; UL

Time Delay

JLLS090

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

90 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 1.642 in (20.6 x 41.7 mm)

1.642 in (41.7 mm)

CSA; UL

Fast

FLSR15ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

15 A

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLSR.250T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLQ05.6T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

5.6 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

KLSR125

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

125 A

Tab/Blade

200 kA

KLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

9.626 in (244.5 mm)

CSA; UL

Fast

KLDR.400TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

400 mA

End Cap

57.9 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLDR012

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

12 A

End Cap

154.7 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLSR002

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.