Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0ATO005.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

26 J

-40 °C (-40 °F)

1 kA

100 ms

Box

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0CNL200.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

200 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

UL

Fast

0CNN600.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

600 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

48 V

3.18 in (80.77 mm)

UL

Very Fast

0HEV050.ZXP2Y

Littelfuse

Electric Fuse

Inline/Holder

275 V

50 A

Tab/Blade

1.495 kJ

-40 °C (-40 °F)

10 kA

50 ms

1.531 in (38.9 mm)

CSA; UL

125 °C (257 °F)

0JTD400.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

400 A

Tab/Blade

1.055 MJ

Nickel

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

600 V

3.374 in (85.7 mm)

CSA; UL

Time Delay

0MIN020.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

380 J

-40 °C (-40 °F)

Silver

1 kA

30 ms

Box

0.429 in (10.9 mm)

0.15 in (3.8 mm)

e4

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0TLS040.TXLSE

Littelfuse

Electric Fuse

Inline/Holder

170 V

40 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

142.6185.5152

Littelfuse

Electric Fuse

Inline/Holder

58 V

15 A

Tab/Blade

250 J

Tin

Rated Breaking Capacity at 58 VDC: 1000 A

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

142.6185.515.2

Littelfuse

Electric Fuse

Inline/Holder

58 V

15 A

Tab/Blade

250 J

Tin

1 kA

Pre Arcing Time: Open within 0.020 s at 600% Rated Current

Bulk

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

CUL; UL

153.5631.5301

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

5.1 kJ

-40 °C (-40 °F)

Tin

1 kA

100 ms

5100

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

170M2106

Eaton Corporation

Electric Fuse

Inline/Holder

1.2 KV

80 A

Tab/Blade

1.97 kJ

100 kA

6.457 in (164 mm)

1.535 in (39 mm)

2.598 in (66 mm)

IEC60269

170M3216

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

250 A

Tab/Blade

4.2 kJ

200 kA

Box

1.969 in (50 mm)

1.772 in (45 mm)

Indicator

1.969 x 1.772 x 1.772 in (50 x 45 x 45 mm)

1.772 in (45 mm)

CE; DIN 43653; IEC; UL

170M3465

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

200 A

Tab/Blade

2.2 kJ

200 kA

Box

1.772 in (45 mm)

1.772 in (45 mm)

Indicator

1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M3467

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

315 A

Tab/Blade

7 kJ

200 kA

Box

1.772 in (45 mm)

1.772 in (45 mm)

Indicator

1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M3468

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

350 A

Tab/Blade

10 kJ

200 kA

Box

1.772 in (45 mm)

1.772 in (45 mm)

Indicator

1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M3541

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

400 A

Tab/Blade

42 kJ

150 kA

1.772 in (45 mm)

Indicator

1.772 x 1.772 in (45 x 45 mm)

1.772 in (45 mm)

CE; IEC; UL

170M4018

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

800 A

Tab/Blade

105 kJ

200 kA

Box

1.969 in (50 mm)

2.087 in (53 mm)

Indicator

1.969 x 2.087 x 2.087 in (50 x 53 x 53 mm)

2.087 in (53 mm)

CE; DIN 43653; IEC; UL

170M4167

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 A

Tab/Blade

69.5 kJ

200 kA

Box

1.969 in (50 mm)

2.087 in (53 mm)

Indicator

1.969 x 2.087 x 2.087 in (50 x 53 x 53 mm)

2.087 in (53 mm)

CE; DIN 43653; IEC; UL

170M5466

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

1 kA

Tab/Blade

180 kJ

200 kA

Box

2.402 in (61 mm)

2.402 in (61 mm)

Indicator

2.402 x 2.402 x 1.969 in (61 x 61 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M5810D

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

500 A

Tab/Blade

155 kJ

200 kA

2.835 in (72 mm)

2.126 in (54 mm)

Indicator

2.835 x 2.126 x 2.677 in (72 x 54 x 68 mm)

2.677 in (68 mm)

CE; CSA; IEC; UL

170M6011

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 A

Tab/Blade

44.5 kJ

200 kA

Box

2.008 in (51 mm)

2.992 in (76 mm)

Indicator

2.008 x 2.992 x 2.992 in (51 x 76 x 76 mm)

2.992 in (76 mm)

CE; DIN 43653; IEC; UL

273.031

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

31 mA

Tab/Blade

10 μJ

-55 °C (-67 °F)

10 kA

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

0.25 in (6.35 mm)

125 V

Micro

0.25 x 0.35 in (6.35 x 8.89 mm)

0.35 in (8.89 mm)

CSA; UL

85 °C (185 °F)

Very Fast

273003

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

3 A

Tab/Blade

759 mJ

-55 °C (-67 °F)

10 kA

2 s

Pre Arcing Time: Open within 2 s at 200% Rated Current

0.25 in (6.35 mm)

125 V

Micro

0.25 x 0.35 in (6.35 x 8.89 mm)

0.35 in (8.89 mm)

CSA; UL

85 °C (185 °F)

Very Fast

45FE

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

45 A

Tab/Blade

76 J

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

1.89 in (48 mm)

1.89 x 0.752 in (48 x 19.1 mm)

0.752 in (19.1 mm)

BS 88; CE

DD160

Eaton Corporation

Electric Fuse

Inline/Holder

415 V

160 A

Tab/Blade

57 kJ

Box

1.22 in (31 mm)

1.22 x 1.85 in (31 x 47 mm)

1.85 in (47 mm)

BS 88; IEC

EV1K125.ZXBD

Littelfuse

Electric Fuse

Inline/Holder

1 KV

125 A

Tab/Blade

4.5 kJ

-40 °C (-40 °F)

30 kA

Bulk

1 in (25.4 mm)

2.875 in (73.03 mm)

125 °C (257 °F)

FLNR150.XXID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

1.535 in (39 mm)

Indicator

7.126 in (181 mm)

CSA; UL

Time Delay

JLLN200.X

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

300 V

2.437 in (61.9 mm)

CE; CSA; CUL; UL

Fast

JLLN350

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.311 in (33.3 mm)

1.311 x 0.827 in (33.3 x 21 mm)

2.752 in (69.9 mm)

CE; CSA; CUL; UL

Fast

JLLS110.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.079 in (27.4 mm)

600 V

1.657 in (42.1 mm)

CE; CSA; UL

Fast

JLLS150.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.079 in (27.4 mm)

600 V

1.657 in (42.1 mm)

CE; CSA; UL

Fast

JTD080

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.126 in (28.6 mm)

2.626 in (66.7 mm)

CSA; UL

Time Delay

KLC30

Littelfuse

Electric Fuse

Inline/Holder

600 V

30 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

L50QS050.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

50 A

Tab/Blade

211 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1 in (25.4 mm)

10 ms

2.125 in (53.98 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

L70QS070.V

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

70 A

Tab/Blade

359 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

Box

1 in (25.4 mm)

2.875 in (73.03 mm)

CUL; UL

125 °C (257 °F)

Very Fast

PF-FB2-50

Bourns

Electric Fuse

Inline/Holder

800 V

800 V

50 A

Tab/Blade

800 J

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 800 VDC: 50000 A

Bulk

0.949 in (24.1 mm)

2.598 in (66 mm)

CUL; UL

125 °C (257 °F)

PSR030UL0550Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

550 A

Tab/Blade

44.323 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR071UL0550Z

Littelfuse

Electric Fuse

Inline/Holder

1.2 KV

900 V

550 A

Tab/Blade

87.328 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 900 VDC: 150000 A

Bulk

2.882 in (73.2 mm)

2.028 in (51.5 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

PV-250ANH2

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

250 A

Tab/Blade

26 kJ

50 kA

17000

Bulk

2.953 in (75 mm)

2.087 in (53 mm)

1 KV

2.953 x 2.087 x 2.402 in (75 x 53 x 61 mm)

2.402 in (61 mm)

CSA; IEC; UL

SPNH250.X2XL

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

250 A

Tab/Blade

73 kJ

30 kA

Bulk

5.165 in (131.2 mm)

2.362 in (60 mm)

NH

2.362 in (60 mm)

UL

02400106P

Littelfuse

Electric Fuse

Inline/Holder

Tab/Blade

-40 °C (-40 °F)

Bulk

125 °C (257 °F)

0257002PXPV

Littelfuse

Electric Fuse

Inline/Holder

32 V

2 A

Tab/Blade

1.4 J

-40 °C (-40 °F)

Tin

1 kA

0257

Rated Breaking Capacity at 32 VDC: 1000 A

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

e3

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

0257002.PXPV

Littelfuse

Electric Fuse

Inline/Holder

32 V

2 A

Tab/Blade

1.4 J

-40 °C (-40 °F)

Tin/Copper

1 kA

0257

Bulk

0.75 in (19.05 mm)

0.2 in (5.08 mm)

e2

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

UL

105 °C (221 °F)

0287004.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

4 A

Tab/Blade

14 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287015.PXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

340 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287025.PXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

1 kJ

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0297003.L

Littelfuse

Electric Fuse

Inline/Holder

32 V

3 A

Tab/Blade

20 J

-40 °C (-40 °F)

Silver

1 kA

30 ms

9.4

0.429 in (10.9 mm)

0.15 in (3.8 mm)

e4

32 V

Mini

0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0297025.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

622 J

-40 °C (-40 °F)

1 kA

30 ms

625

0.429 in (10.9 mm)

0.15 in (3.8 mm)

32 V

Mini

0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.