Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
1.25 kA |
Tab/Blade |
995.376 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
5.067 in (128.7 mm) |
2.894 in (73.5 mm) |
Indicator |
2.894 in (73.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
10 A |
Tab/Blade |
7 J |
-40 °C (-40 °F) |
50 kA |
Box |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CCC; CSA; IEC; UL |
90 °C (194 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
200 A |
Tab/Blade |
79.642 kJ |
20 kA |
10 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
Midget |
3.012 in (76.5 mm) |
CE; IEC; UL; VDE |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
250 A |
Tab/Blade |
85.9 kJ |
200 kA |
12 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
2 in (50.8 mm) |
Midget |
2 x 3.374 in (50.8 x 85.7 mm) |
3.374 in (85.7 mm) |
CE; IEC; UL; VDE |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
80 V |
40 A |
Tab/Blade |
100 kA |
Rated Breaking Capacity at 80 VDC: 100000 A |
1.846 in (46.89 mm) |
0.547 in (13.89 mm) |
Alarm |
1.846 x 0.547 x 1.824 in (46.89 x 13.89 x 46.34 mm) |
1.824 in (46.34 mm) |
CE; UL |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
ISO; UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
Silver |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
e4 |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
125 A |
Tab/Blade |
57.8 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
400 A |
Tab/Blade |
-40 °C (-40 °F) |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
400 A |
Tab/Blade |
610 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
0.421 in (10.7 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
400 A |
Tab/Blade |
610 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.421 in (10.7 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
400 A |
Tab/Blade |
-40 °C (-40 °F) |
Silver |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
e4 |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
400 A |
Tab/Blade |
-40 °C (-40 °F) |
Silver |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
e4 |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
60 A |
Tab/Blade |
21.7 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
10 A |
Tab/Blade |
102 J |
-40 °C (-40 °F) |
1 kA |
30 ms |
Bulk |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
58 V |
Mini |
0.299 in (7.6 mm) |
ISO |
125 °C (257 °F) |
|||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
500 V |
300 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
50 kA |
Bulk |
1.929 in (49 mm) |
1.457 in (37 mm) |
e3 |
0.945 in (24 mm) |
105 °C (221 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
400 A |
Tab/Blade |
1.055 MJ |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
2 in (50.8 mm) |
600 V |
Indicator |
3.374 in (85.7 mm) |
CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
80 V |
3 A |
Tab/Blade |
8.1 J |
Tin |
Rated Breaking Capacity at 80 VDC: 1000A |
0.748 in (19 mm) |
0.197 in (5 mm) |
e3 |
0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm) |
0.52 in (13.2 mm) |
UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
800 A |
Tab/Blade |
86 kJ |
200 kA |
Box |
1.969 in (50 mm) |
2.402 in (61 mm) |
Indicator |
1.969 x 2.402 x 2.402 in (50 x 61 x 61 mm) |
2.402 in (61 mm) |
CE; DIN 43653; IEC; UL |
||||||||||||||||
Siba |
Electric Fuse |
Inline/Holder |
700 V |
50 A |
Tab/Blade |
140 J |
200 kA |
Bulk |
2.165 in (55 mm) |
0.807 in (20.5 mm) |
700 V |
Indicator |
2.756 in (70 mm) |
IEC, UL, VDE |
Very Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
15 A |
Tab/Blade |
340 J |
Tin Copper |
1 kA |
80 ms |
Pre Arcing Time: Open within 0.08 s at 350% Rated Current |
0.75 in (19.05 mm) |
0.2 in (5.08 mm) |
ATO |
e2 |
32 V |
0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm) |
0.48 in (12.19 mm) |
CSA; UL |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
125 V |
63 mA |
Tab/Blade |
120 μJ |
-55 °C (-67 °F) |
Tin/Lead |
10 kA |
Rated Breaking Capacity at 125 VDC: 10000 A |
0.235 in (5.97 mm) |
e0 |
0.235 x 0.287 in (5.97 x 7.3 mm) |
0.287 in (7.3 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Siemens |
Electric Fuse |
Inline/Holder |
1 KV |
450 A |
Tab/Blade |
-20 °C (-4 °F) |
100 kA |
2.874 in (73 mm) |
2.047 in (52 mm) |
Indicator |
2.874 x 2.047 x 2.047 in (73 x 52 x 52 mm) |
2.047 in (52 mm) |
CCC; CE; UL |
50 °C (122 °F) |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
450 A |
Tab/Blade |
30 kJ |
200 kA |
Rated Breaking Capacity at 350 VDC: 200000 A |
Box |
3.268 in (83 mm) |
3.268 x 1.969 in (83 x 50 mm) |
1.969 in (50 mm) |
BS 88; CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
560 A |
Tab/Blade |
60 kJ |
200 kA |
Rated Breaking Capacity at 350 VDC: 200000 A |
Box |
3.268 in (83 mm) |
3.268 x 1.969 in (83 x 50 mm) |
1.969 in (50 mm) |
BS 88; CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
630 A |
Tab/Blade |
68.5 kJ |
200 kA |
Rated Breaking Capacity at 350 VDC: 200000 A |
Box |
3.268 in (83 mm) |
3.268 x 1.969 in (83 x 50 mm) |
1.969 in (50 mm) |
BS 88; CE; IEC; UL |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
150 V |
150 V |
1 kA |
Tab/Blade |
100 kA |
Rated Breaking Capacity at 150 VDC: 50000 A |
1.5 in (38.1 mm) |
Indicator |
1.5 x 1.252 in (38.1 x 31.8 mm) |
1.252 in (31.8 mm) |
UL |
Fast |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
300 A |
Tab/Blade |
200 kA |
2.52 in (64 mm) |
J |
600 V |
7.992 in (203 mm) |
IEC, UL |
Time Lag |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
1 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin over Copper |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
32 V |
0.76 x 0.207 x 0.492 in (19.3 x 5.25 x 12.5 mm) |
0.483 in (12.28 mm) |
UL |
100 °C (212 °F) |
Fast |
|||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
70 A |
Tab/Blade |
200 kA |
Bulk |
1.06 in (26.924 mm) |
5.88 in (149.352 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
225 A |
Tab/Blade |
7.162 kJ |
-40 °C (-40 °F) |
25 kA |
Box |
1.5 in (38.1 mm) |
2.843 in (72.2 mm) |
UL |
125 °C (257 °F) |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
275 A |
Tab/Blade |
11.796 kJ |
-40 °C (-40 °F) |
25 kA |
Box |
1.5 in (38.1 mm) |
2.843 in (72.2 mm) |
UL |
125 °C (257 °F) |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
35 A |
Tab/Blade |
200 kA |
0.811 in (20.6 mm) |
0.811 x 2.094 in (20.6 x 53.2 mm) |
2.094 in (53.2 mm) |
UL |
||||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
35 A |
Tab/Blade |
34 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
Box |
0.813 in (20.65 mm) |
0.813 x 2.75 in (20.65 x 69.85 mm) |
2.75 in (69.85 mm) |
CE; CSA; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 A |
Tab/Blade |
200 kA |
3.626 in (92.1 mm) |
3.626 x 1.736 in (92.1 x 44.1 mm) |
1.736 in (44.1 mm) |
CE; CSA; UL |
Very Fast |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
400 A |
Tab/Blade |
200 kA |
2.11 in (53.6 mm) |
J |
600 V |
2.11 x 1.508 in (53.6 x 38.3 mm) |
1.508 in (38.3 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.079 in (27.4 mm) |
600 V |
1.657 in (42.1 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
2 A |
Tab/Blade |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
150 V |
1 kA |
Tab/Blade |
520 J |
100 kA |
Rated Breaking Capacity at 150 VDC: 100000 A |
1.5 in (38.1 mm) |
1.5 x 1.252 in (38.1 x 31.8 mm) |
1.252 in (31.8 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
80 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.126 in (28.6 mm) |
J |
600 V |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
Box |
0.35 in (8.9 mm) |
0.35 in (8.9 mm) |
32 V |
0.35 x 0.35 x 0.85 in (8.9 x 8.9 x 21.6 mm) |
0.85 in (21.6 mm) |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
4.1 kJ |
-40 °C (-40 °F) |
1 kA |
40 ms |
Box |
1.15 in (29.2 mm) |
0.346 in (8.8 mm) |
0.85 in (21.6 mm) |
UL |
125 °C (257 °F) |
Slow |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
30 A |
Tab/Blade |
50 kA |
1 m 40 s |
Bulk |
1.5 in (38.1 mm) |
0.406 in (10.3 mm) |
1 KV |
1.5 x 0.406 x 0.555 in (38.1 x 10.3 x 14.1 mm) |
0.555 in (14.1 mm) |
IATF 16949; UL |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 A |
Tab/Blade |
10 kA |
Box |
2.59 in (65.79 mm) |
H |
600 V |
2.59 x 11.63 in (65.79 x 295.4 mm) |
11.63 in (295.4 mm) |
CE; CSA; UL |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
550 V |
10 A |
Tab/Blade |
120 J |
80 kA |
Box |
0.543 in (13.8 mm) |
0.543 x 1.362 in (13.8 x 34.6 mm) |
1.362 in (34.6 mm) |
IEC |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
550 V |
100 A |
Tab/Blade |
25 kJ |
80 kA |
Box |
0.827 in (21 mm) |
0.827 x 2.146 in (21 x 54.5 mm) |
2.146 in (54.5 mm) |
IEC |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.