Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

PSX3XLUB1250X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

1.25 kA

Tab/Blade

995.376 kJ

-55 °C (-67 °F)

250 kA

Bulk

5.067 in (128.7 mm)

2.894 in (73.5 mm)

Indicator

2.894 in (73.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PV-10A10-T

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

10 A

Tab/Blade

7 J

-40 °C (-40 °F)

50 kA

Box

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CCC; CSA; IEC; UL

90 °C (194 °F)

SPFJ200.XXL

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

200 A

Tab/Blade

79.642 kJ

20 kA

10 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Midget

3.012 in (76.5 mm)

CE; IEC; UL; VDE

SPFJ250.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

250 A

Tab/Blade

85.9 kJ

200 kA

12 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

2 in (50.8 mm)

Midget

2 x 3.374 in (50.8 x 85.7 mm)

3.374 in (85.7 mm)

CE; IEC; UL; VDE

TPC-40

Eaton Corporation

Electric Fuse

Inline/Holder

80 V

40 A

Tab/Blade

100 kA

Rated Breaking Capacity at 80 VDC: 100000 A

1.846 in (46.89 mm)

0.547 in (13.89 mm)

Alarm

1.846 x 0.547 x 1.824 in (46.89 x 13.89 x 46.34 mm)

1.824 in (46.34 mm)

CE; UL

0298125.UXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

57.8 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0298125.ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

57.8 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0298125.ZXEH-UL

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

57.8 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.39 in (9.9 mm)

ISO; UL

125 °C (257 °F)

Time Delay

0298125ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

57.8 kJ

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0298125ZXEH-UL

Littelfuse

Electric Fuse

Inline/Holder

32 V

125 A

Tab/Blade

57.8 kJ

-40 °C (-40 °F)

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

UL

125 °C (257 °F)

Time Delay

0298400.TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

400 A

Tab/Blade

-40 °C (-40 °F)

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0298400.ZXA

Littelfuse

Electric Fuse

Inline/Holder

32 V

400 A

Tab/Blade

610 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

0298400.ZXH

Littelfuse

Electric Fuse

Inline/Holder

32 V

400 A

Tab/Blade

610 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

0298400TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

400 A

Tab/Blade

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0298400ZXH

Littelfuse

Electric Fuse

Inline/Holder

32 V

400 A

Tab/Blade

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0498060.MXM6

Littelfuse

Electric Fuse

Inline/Holder

32 V

60 A

Tab/Blade

21.7 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

0891010.NXS

Littelfuse

Electric Fuse

Inline/Holder

58 V

10 A

Tab/Blade

102 J

-40 °C (-40 °F)

1 kA

30 ms

Bulk

0.429 in (10.9 mm)

0.15 in (3.8 mm)

58 V

Mini

0.299 in (7.6 mm)

ISO

125 °C (257 °F)

0AKRBK300-BB

Bel Fuse

Electric Fuse

Inline/Holder

500 V

300 A

Tab/Blade

-40 °C (-40 °F)

Tin

50 kA

Bulk

1.929 in (49 mm)

1.457 in (37 mm)

e3

0.945 in (24 mm)

105 °C (221 °F)

0JTD400.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

400 A

Tab/Blade

1.055 MJ

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

600 V

Indicator

3.374 in (85.7 mm)

CSA; UL

Time Delay

166.7000.4302

Littelfuse

Electric Fuse

Inline/Holder

80 V

3 A

Tab/Blade

8.1 J

Tin

Rated Breaking Capacity at 80 VDC: 1000A

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

170M5264

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

800 A

Tab/Blade

86 kJ

200 kA

Box

1.969 in (50 mm)

2.402 in (61 mm)

Indicator

1.969 x 2.402 x 2.402 in (50 x 61 x 61 mm)

2.402 in (61 mm)

CE; DIN 43653; IEC; UL

2028220.50

Siba

Electric Fuse

Inline/Holder

700 V

50 A

Tab/Blade

140 J

200 kA

Bulk

2.165 in (55 mm)

0.807 in (20.5 mm)

700 V

Indicator

2.756 in (70 mm)

IEC, UL, VDE

Very Fast

257015

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

340 J

Tin Copper

1 kA

80 ms

Pre Arcing Time: Open within 0.08 s at 350% Rated Current

0.75 in (19.05 mm)

0.2 in (5.08 mm)

ATO

e2

32 V

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

CSA; UL

Fast

272.062

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

63 mA

Tab/Blade

120 μJ

-55 °C (-67 °F)

Tin/Lead

10 kA

Rated Breaking Capacity at 125 VDC: 10000 A

0.235 in (5.97 mm)

e0

0.235 x 0.287 in (5.97 x 7.3 mm)

0.287 in (7.3 mm)

CSA; UL

125 °C (257 °F)

Very Fast

3NE3233

Siemens

Electric Fuse

Inline/Holder

1 KV

450 A

Tab/Blade

-20 °C (-4 °F)

100 kA

2.874 in (73 mm)

2.047 in (52 mm)

Indicator

2.874 x 2.047 x 2.047 in (73 x 52 x 52 mm)

2.047 in (52 mm)

CCC; CE; UL

50 °C (122 °F)

450MMT

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

450 A

Tab/Blade

30 kJ

200 kA

Rated Breaking Capacity at 350 VDC: 200000 A

Box

3.268 in (83 mm)

3.268 x 1.969 in (83 x 50 mm)

1.969 in (50 mm)

BS 88; CE; IEC; UL

560MMT

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

560 A

Tab/Blade

60 kJ

200 kA

Rated Breaking Capacity at 350 VDC: 200000 A

Box

3.268 in (83 mm)

3.268 x 1.969 in (83 x 50 mm)

1.969 in (50 mm)

BS 88; CE; IEC; UL

630MMT

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

630 A

Tab/Blade

68.5 kJ

200 kA

Rated Breaking Capacity at 350 VDC: 200000 A

Box

3.268 in (83 mm)

3.268 x 1.969 in (83 x 50 mm)

1.969 in (50 mm)

BS 88; CE; IEC; UL

A15QS1000-4IL

Mersen S A

Electric Fuse

Inline/Holder

150 V

150 V

1 kA

Tab/Blade

100 kA

Rated Breaking Capacity at 150 VDC: 50000 A

1.5 in (38.1 mm)

Indicator

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

UL

Fast

AJT300/600

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

300 A

Tab/Blade

200 kA

2.52 in (64 mm)

J

600 V

7.992 in (203 mm)

IEC, UL

Time Lag

ATC-1

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

32 V

1 A

Tab/Blade

-40 °C (-40 °F)

Tin over Copper

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

32 V

0.76 x 0.207 x 0.492 in (19.3 x 5.25 x 12.5 mm)

0.483 in (12.28 mm)

UL

100 °C (212 °F)

Fast

ECNR70

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

70 A

Tab/Blade

200 kA

Bulk

1.06 in (26.924 mm)

5.88 in (149.352 mm)

CE; CSA; UL

Time Delay

EVK40-225

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

225 A

Tab/Blade

7.162 kJ

-40 °C (-40 °F)

25 kA

Box

1.5 in (38.1 mm)

2.843 in (72.2 mm)

UL

125 °C (257 °F)

EVK40-275

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

275 A

Tab/Blade

11.796 kJ

-40 °C (-40 °F)

25 kA

Box

1.5 in (38.1 mm)

2.843 in (72.2 mm)

UL

125 °C (257 °F)

FBP-35

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

35 A

Tab/Blade

200 kA

0.811 in (20.6 mm)

0.811 x 2.094 in (20.6 x 53.2 mm)

2.094 in (53.2 mm)

UL

FWP-35B

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

35 A

Tab/Blade

34 J

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

Box

0.813 in (20.65 mm)

0.813 x 2.75 in (20.65 x 69.85 mm)

2.75 in (69.85 mm)

CE; CSA; UL

JJS-300

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 A

Tab/Blade

200 kA

3.626 in (92.1 mm)

3.626 x 1.736 in (92.1 x 44.1 mm)

1.736 in (44.1 mm)

CE; CSA; UL

Very Fast

JKS-400

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

400 A

Tab/Blade

200 kA

2.11 in (53.6 mm)

J

600 V

2.11 x 1.508 in (53.6 x 38.3 mm)

1.508 in (38.3 mm)

CE; CSA; UL

Fast

JLLS125.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

125 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.079 in (27.4 mm)

600 V

1.657 in (42.1 mm)

CE; CSA; UL

Fast

KLKR002

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 A

Tab/Blade

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

LA15QS1000-4IL

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

1 kA

Tab/Blade

520 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

UL

Very Fast

LPJ-80SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

80 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.126 in (28.6 mm)

J

600 V

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; UL

Time Delay

MAX-30

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

Box

0.35 in (8.9 mm)

0.35 in (8.9 mm)

32 V

0.35 x 0.35 x 0.85 in (8.9 x 8.9 x 21.6 mm)

0.85 in (21.6 mm)

Fast

MAX30

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

4.1 kJ

-40 °C (-40 °F)

1 kA

40 ms

Box

1.15 in (29.2 mm)

0.346 in (8.8 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Slow

MEV100C30-S

Mersen S A

Electric Fuse

Inline/Holder

1 KV

30 A

Tab/Blade

50 kA

1 m 40 s

Bulk

1.5 in (38.1 mm)

0.406 in (10.3 mm)

1 KV

1.5 x 0.406 x 0.555 in (38.1 x 10.3 x 14.1 mm)

0.555 in (14.1 mm)

IATF 16949; UL

NOS-300

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 A

Tab/Blade

10 kA

Box

2.59 in (65.79 mm)

H

600 V

2.59 x 11.63 in (65.79 x 295.4 mm)

11.63 in (295.4 mm)

CE; CSA; UL

NSD10

Eaton Corporation

Electric Fuse

Inline/Holder

550 V

10 A

Tab/Blade

120 J

80 kA

Box

0.543 in (13.8 mm)

0.543 x 1.362 in (13.8 x 34.6 mm)

1.362 in (34.6 mm)

IEC

OSD100

Eaton Corporation

Electric Fuse

Inline/Holder

550 V

100 A

Tab/Blade

25 kJ

80 kA

Box

0.827 in (21 mm)

0.827 x 2.146 in (21 x 54.5 mm)

2.146 in (54.5 mm)

IEC

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.