Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
80 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.142 x 2.638 in (29 x 67 mm) |
4.606 in (117 mm) |
Time Delay |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Surface Mount |
125 V |
80 V |
250 A |
Tab/Blade |
2.5 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Very Fast |
||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
200 A |
Tab/Blade |
200 kA |
1.5 in (38.1 mm) |
1.5 x 3 in (38.1 x 76.2 mm) |
3 in (76.2 mm) |
CSA |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
6 A |
Tab/Blade |
210 J |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
550 V |
32 A |
Tab/Blade |
710 J |
80 kA |
Box |
0.539 in (13.7 mm) |
0.539 x 1.362 in (13.7 x 34.6 mm) |
1.362 in (34.6 mm) |
IEC |
||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
450 A |
Tab/Blade |
50 kA |
Rated Breaking Capacity at 250 VDC: 20000 A |
2.598 in (66 mm) |
2.598 x 5.906 in (66 x 150 mm) |
5.906 in (150 mm) |
CSA; UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
2 A |
Tab/Blade |
9 J |
-40 °C (-40 °F) |
Tin |
1 kA |
30 ms |
2.8 |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
e3 |
32 V |
Mini |
0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm) |
0.346 in (8.8 mm) |
UL |
125 °C (257 °F) |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
60 A |
Tab/Blade |
15.3 kJ |
-40 °C (-40 °F) |
Silver |
1 kA |
40 ms |
15300 |
Bulk |
1.15 in (29.2 mm) |
0.346 in (8.8 mm) |
e4 |
32 V |
1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm) |
0.85 in (21.6 mm) |
UL |
125 °C (257 °F) |
Time Delay |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
1 KV |
160 A |
Tab/Blade |
5.4 kJ |
-40 °C (-40 °F) |
Tin |
50 kA |
Bulk |
2.913 in (74 mm) |
0.866 in (22 mm) |
e3 |
0.984 in (25 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
10 A |
Tab/Blade |
115 J |
-40 °C (-40 °F) |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
0.484 in (12.3 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
110 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
3 in (76.2 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
110 A |
Tab/Blade |
600 J |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
1.811 in (46 mm) |
1.811 x 0.748 in (46 x 19 mm) |
0.748 in (19 mm) |
BS 88; CE |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
1.25 kA |
Tab/Blade |
7 MJ |
120 kA |
Box |
3.543 in (90 mm) |
3.425 in (87 mm) |
NH4 |
Indicator |
4.016 in (102 mm) |
CE; DIN; IEC; VDE |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
60 A |
Tab/Blade |
16.2 kJ |
-40 °C (-40 °F) |
Matte Tin |
1 kA |
16200 |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
58 V |
0.472 x 0.307 x 0.63 in (12 x 7.8 x 16 mm) |
0.307 in (7.8 mm) |
UL |
125 °C (257 °F) |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
5.1 kJ |
-40 °C (-40 °F) |
1 kA |
100 ms |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
40 A |
Tab/Blade |
6.8 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
60 A |
Tab/Blade |
16.2 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
70 A |
Tab/Blade |
22 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
80 A |
Tab/Blade |
25.6 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
200 A |
Tab/Blade |
126 kJ |
-40 °C (-40 °F) |
1.5 kA |
100 ms |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.315 in (8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
315 A |
Tab/Blade |
12 kJ |
200 kA |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm) |
1.575 in (40 mm) |
CE; CSA; DIN 43653; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
63 A |
Tab/Blade |
170 J |
200 kA |
Box |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
315 A |
Tab/Blade |
10 kJ |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
1.969 in (50 mm) |
1.969 x 1.614 in (50 x 41 mm) |
1.614 in (41 mm) |
BS 88; CE |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
15 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
0.429 in (10.9 mm) |
0.15 in (3.81 mm) |
32 V |
0.429 x 0.15 x 0.344 in (10.9 x 3.81 x 8.73 mm) |
0.344 in (8.73 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
7.5 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
Box |
0.43 in (10.92 mm) |
0.15 in (3.81 mm) |
e3 |
32 V |
0.43 x 0.15 x 0.347 in (10.92 x 3.81 x 8.81 mm) |
0.347 in (8.81 mm) |
UL |
100 °C (212 °F) |
Fast |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
1 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
32 V |
0.76 x 0.207 x 0.492 in (19.3 x 5.25 x 12.5 mm) |
0.483 in (12.28 mm) |
UL |
100 °C (212 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
75 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
1.031 in (26.2 mm) |
5.874 in (149.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
1 kA |
Tab/Blade |
190 kJ |
100 kA |
Box |
3.5 in (88.9 mm) |
3.5 x 3.312 in (88.9 x 84.12 mm) |
3.312 in (84.12 mm) |
UL |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
1.2 kA |
Tab/Blade |
370 kJ |
100 kA |
Box |
3.5 in (88.9 mm) |
3.5 x 3.312 in (88.9 x 84.12 mm) |
3.312 in (84.12 mm) |
UL |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
800 V |
400 A |
Tab/Blade |
47 kJ |
100 kA |
Rated Breaking Capacity at 800 VDC: 50000 A |
Box |
2 in (50.8 mm) |
2 x 3.5 in (50.8 x 88.9 mm) |
3.5 in (88.9 mm) |
CE; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
400 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.311 in (33.3 mm) |
300 V |
2.752 in (69.9 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
400 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.311 in (33.3 mm) |
300 V |
2.752 in (69.9 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
400 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.311 in (33.3 mm) |
2.752 in (69.9 mm) |
CE; CSA; CUL; UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
60 A |
Tab/Blade |
269 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Bulk |
1 in (25.4 mm) |
10 ms |
2.125 in (53.98 mm) |
CE; CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
40 A |
Tab/Blade |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
Box |
0.35 in (8.9 mm) |
0.35 in (8.9 mm) |
32 V |
0.35 x 0.35 x 0.85 in (8.9 x 8.9 x 21.6 mm) |
0.85 in (21.6 mm) |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
40 A |
Tab/Blade |
8.5 kJ |
-40 °C (-40 °F) |
1 kA |
40 ms |
Box |
1.15 in (29.2 mm) |
0.346 in (8.8 mm) |
0.85 in (21.6 mm) |
UL |
125 °C (257 °F) |
Slow |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
5 A |
Tab/Blade |
17 J |
-40 °C (-40 °F) |
1 kA |
20 ms |
Box |
0.358 in (9.1 mm) |
0.15 in (3.8 mm) |
Micro |
0.311 in (7.9 mm) |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
5 A |
Tab/Blade |
17 J |
-40 °C (-40 °F) |
1 kA |
20 ms |
Bulk |
0.358 in (9.1 mm) |
0.15 in (3.8 mm) |
Micro |
0.311 in (7.9 mm) |
125 °C (257 °F) |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
150 A |
Tab/Blade |
10 kA |
Rated Breaking Capacity at 125 VDC: 10000 A |
Box |
1.56 in (39.62 mm) |
H |
250 V |
1.56 x 7.13 in (39.62 x 181.1 mm) |
7.13 in (181.1 mm) |
CE; CSA; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
450 A |
Tab/Blade |
565.333 kJ |
200 kA |
14 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
2.5 in (63.5 mm) |
Midget |
2.5 x 3.752 in (63.5 x 95.3 mm) |
3.752 in (95.3 mm) |
CE; IEC; UL; VDE |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
690 V |
200 A |
Tab/Blade |
2.6 kJ |
200 kA |
Bulk |
1.874 in (47.6 mm) |
2.008 in (51 mm) |
Indicator |
2.224 in (56.5 mm) |
CCC; CE; CSA; EAC; IEC; UL; VDE |
Ultra Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
3 A |
Tab/Blade |
7.4 J |
-40 °C (-40 °F) |
Tin |
1 kA |
80 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm) |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
3 A |
Tab/Blade |
7.4 J |
-40 °C (-40 °F) |
Tin |
1 kA |
80 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
3 A |
Tab/Blade |
7.4 J |
-40 °C (-40 °F) |
Tin |
1 kA |
80 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
1.23 kJ |
-40 °C (-40 °F) |
Silver |
1 kA |
30 ms |
1130 |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
e4 |
32 V |
Mini |
0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm) |
0.346 in (8.8 mm) |
UL |
125 °C (257 °F) |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
40 A |
Tab/Blade |
8.7 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
40 A |
Tab/Blade |
8.7 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.39 in (29.2 x 19.05 x 9.9 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.