Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0299040.ZXNV

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

8.5 kJ

-40 °C (-40 °F)

Silver

1 kA

40 ms

8450

Bulk

1.15 in (29.2 mm)

0.346 in (8.8 mm)

e4

32 V

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Time Delay

0299040ZXNV

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

8.45 kJ

-40 °C (-40 °F)

Silver

Rated Breaking Capacity at 32 VDC: 1000 A

1.15 in (29.21 mm)

0.348 in (8.85 mm)

e4

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.59 mm)

125 °C (257 °F)

0495030.ZXA

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.5 kJ

-40 °C (-40 °F)

1 kA

40 ms

0.555 in (14.1 mm)

0.472 in (12 mm)

32 V

1.063 in (27 mm)

UL

125 °C (257 °F)

Time Delay

0495030ZXA

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.5 kJ

-40 °C (-40 °F)

1 kA

40 ms

0.555 in (14.1 mm)

0.472 in (12 mm)

32 V

1.063 in (27 mm)

UL

125 °C (257 °F)

Time Delay

0498100.MX1M5

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

51.3 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

UL

125 °C (257 °F)

Time Delay

0498100.MX1M5-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

51.3 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

UL

125 °C (257 °F)

Time Delay

0498100.MX1M6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

51.3 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.327 in (8.3 mm)

UL

125 °C (257 °F)

Time Delay

0498100.MXM6

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

51.3 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

UL

125 °C (257 °F)

Time Delay

0498100.MXM6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

51.3 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

UL

125 °C (257 °F)

Time Delay

0498100.MXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

51.3 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

UL

125 °C (257 °F)

Time Delay

0498100.MXT-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

51.3 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.327 in (8.3 mm)

UL

125 °C (257 °F)

Time Delay

0498100.MXTM6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

51.3 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.327 in (8.3 mm)

UL

125 °C (257 °F)

Time Delay

142.5631.6152

Littelfuse

Electric Fuse

Inline/Holder

58 V

150 A

Tab/Blade

83.4 kJ

-40 °C (-40 °F)

Matte Tin

1 kA

100 ms

83400

0.63 in (16 mm)

0.472 in (12 mm)

e3

58 V

0.472 x 0.307 x 0.63 in (12 x 7.8 x 16 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

170M3014

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

160 A

Tab/Blade

1.1 kJ

200 kA

Box

1.969 in (50 mm)

1.772 in (45 mm)

Indicator

1.969 x 1.772 x 1.772 in (50 x 45 x 45 mm)

1.772 in (45 mm)

CE; DIN 43653; IEC; UL

A4J200

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.614 in (41 mm)

1.614 x 2.992 in (41 x 76 mm)

2.992 in (76 mm)

CSA; UL

Fast

ACK-75

Eaton Corporation

Electric Fuse

Inline/Holder

130 V

75 A

Tab/Blade

1.062 in (26.98 mm)

1.062 x 3.5 in (26.98 x 88.9 mm)

3.5 in (88.9 mm)

UL

ATM-10LP

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

-40 °C (-40 °F)

1 kA

0.429 in (10.9 mm)

0.15 in (3.81 mm)

32 V

0.429 x 0.15 x 0.344 in (10.9 x 3.81 x 8.73 mm)

0.344 in (8.73 mm)

125 °C (257 °F)

Fast

FWH-450A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

450 A

Tab/Blade

24.7 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

2 in (50.8 mm)

2 x 2.09 in (50.8 x 53.09 mm)

2.09 in (53.09 mm)

CE; CSA; UL

FWH-500A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

500 A

Tab/Blade

29.2 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

2 in (50.8 mm)

2 x 2.09 in (50.8 x 53.09 mm)

2.09 in (53.09 mm)

CE; CSA; UL

JJS-100

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

200 kA

2.953 in (75 mm)

2.953 x 1.642 in (75 x 41.7 mm)

1.642 in (41.7 mm)

CE; CSA; UL

Very Fast

JJS-250

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

250 A

Tab/Blade

200 kA

3.626 in (92.1 mm)

3.626 x 1.736 in (92.1 x 44.1 mm)

1.736 in (44.1 mm)

CE; CSA; UL

Very Fast

KLKR020.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

20 A

Tab/Blade

900 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

KRP-C-1800SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

1.8 kA

Tab/Blade

Silver

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

3.5 in (88.9 mm)

L

e4

600 V

3.5 x 3.752 in (88.9 x 95.3 mm)

3.752 in (95.3 mm)

CE; CSA; UL

Time Delay

MEV100A125-4Y

Mersen S A

Electric Fuse

Inline/Holder

1 KV

125 A

Tab/Blade

100 kA

80 ms

Bulk

1.22 in (31 mm)

2.874 in (73 mm)

IATF 16949; UL

TPC-75

Eaton Corporation

Electric Fuse

Inline/Holder

80 V

75 A

Tab/Blade

100 kA

Rated Breaking Capacity at 80 VDC: 100000 A

1.846 in (46.89 mm)

0.547 in (13.89 mm)

Alarm

1.846 x 0.547 x 1.824 in (46.89 x 13.89 x 46.34 mm)

1.824 in (46.34 mm)

CE; UL

0297002.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

2 A

Tab/Blade

9 J

-40 °C (-40 °F)

Silver

1 kA

30 ms

2.8

0.429 in (10.9 mm)

0.15 in (3.8 mm)

e4

32 V

Mini

0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0297015.WXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

308 J

-40 °C (-40 °F)

1 kA

30 ms

0.429 in (10.9 mm)

0.15 in (3.8 mm)

32 V

Mini

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0498050.M

Littelfuse

Electric Fuse

Inline/Holder

32 V

50 A

Tab/Blade

13 kJ

-40 °C (-40 °F)

Tin

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

0JTD125.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

125 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

3 in (76.2 mm)

CSA; UL

Time Delay

170M4460

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

315 A

Tab/Blade

6.2 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

350FM

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

350 A

Tab/Blade

15 kJ

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

1.969 in (50 mm)

1.969 x 1.614 in (50 x 41 mm)

1.614 in (41 mm)

BS 88; CE

ANN-400

Eaton Corporation

Electric Fuse

Surface Mount

125 V

80 V

400 A

Tab/Blade

2.5 kA

3.189 in (81 mm)

Indicator

3.189 x 0.874 in (81 x 22.2 mm)

0.874 in (22.2 mm)

CSA; UL

Very Fast

MEV100A250-4

Mersen S A

Electric Fuse

Inline/Holder

1 KV

250 A

Tab/Blade

100 kA

80 ms

Bulk

1.5 in (38.1 mm)

2.843 in (72.2 mm)

IATF 16949; UL

MEV100A70-4Y

Mersen S A

Electric Fuse

Inline/Holder

1 KV

70 A

Tab/Blade

100 kA

40 ms

Bulk

1 in (25.4 mm)

2.874 in (73 mm)

IATF 16949; UL

SPFJ160.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

160 A

Tab/Blade

60.1 kJ

200 kA

10 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Midget

1.5 x 3 in (38.1 x 76.2 mm)

3.012 in (76.5 mm)

CE; IEC; UL

0287010.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

115 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287010.PXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

115 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0AKHBK350-BA

Bel Fuse

Electric Fuse

Inline/Holder

1 KV

350 A

Tab/Blade

Tin

50 kA

Bulk

2.827 in (71.8 mm)

1.85 in (47 mm)

e3

1.89 in (48 mm)

Fast

0MIN005.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

25 J

-40 °C (-40 °F)

1 kA

30 ms

Box

0.429 in (10.9 mm)

0.15 in (3.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

ATC-20

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

32 V

20 A

Tab/Blade

-40 °C (-40 °F)

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

32 V

0.76 x 0.207 x 0.492 in (19.3 x 5.25 x 12.5 mm)

0.483 in (12.28 mm)

UL

100 °C (212 °F)

Fast

JJN-80

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

160 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 160 VDC: 20000 A

Box

0.752 in (19.1 mm)

0.752 x 0.843 in (19.1 x 21.4 mm)

0.843 in (21.4 mm)

CE; CSA; UL

Very Fast

JJN-800

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

170 V

800 A

Tab/Blade

200 kA

Rated Breaking Capacity at 170 VDC: 100000 A

Box

1.752 in (44.5 mm)

1.752 x 0.89 in (44.5 x 22.6 mm)

0.89 in (22.6 mm)

CE; CSA; UL

Very Fast

LPJ-500SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

500 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

2.598 in (66 mm)

J

600 V

2.598 x 1.52 in (66 x 38.6 mm)

1.52 in (38.6 mm)

CE; CSA; UL

Time Delay

MEV100A150-4Y

Mersen S A

Electric Fuse

Inline/Holder

1 KV

150 A

Tab/Blade

100 kA

80 ms

Bulk

1.22 in (31 mm)

2.874 in (73 mm)

IATF 16949; UL

MEV100A200-4

Mersen S A

Electric Fuse

Inline/Holder

1 KV

200 A

Tab/Blade

100 kA

80 ms

Bulk

1.22 in (31 mm)

2.874 in (73 mm)

IATF 16949; UL

MEV100A200-4Y

Mersen S A

Electric Fuse

Inline/Holder

1 KV

200 A

Tab/Blade

100 kA

80 ms

Bulk

1.22 in (31 mm)

2.874 in (73 mm)

IATF 16949; UL

MEV100A225-4

Mersen S A

Electric Fuse

Inline/Holder

1 KV

225 A

Tab/Blade

100 kA

80 ms

Bulk

1.5 in (38.1 mm)

2.843 in (72.2 mm)

IATF 16949; UL

MEV100A300-4

Mersen S A

Electric Fuse

Inline/Holder

1 KV

300 A

Tab/Blade

100 kA

80 ms

Bulk

1.5 in (38.1 mm)

2.843 in (72.2 mm)

IATF 16949; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.