Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
25 A |
Tab/Blade |
25 J |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
1.89 in (48 mm) |
1.89 x 0.752 in (48 x 19.1 mm) |
0.752 in (19.1 mm) |
BS 88; CE |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
250 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
2.126 in (54 mm) |
Indicator |
2.126 x 3.346 in (54 x 85 mm) |
7.126 in (181 mm) |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
250 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
Indicator |
3.236 in (82.2 mm) |
3.236 in (82.2 mm) |
UL |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
250 A |
Tab/Blade |
200 kA |
2.126 in (54 mm) |
7.126 in (181 mm) |
CSA; IEC; UL |
Time Delay |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
550 V |
40 A |
Tab/Blade |
1.4 kJ |
80 kA |
Box |
0.827 in (21 mm) |
0.827 x 2.126 in (21 x 54 mm) |
2.126 in (54 mm) |
IEC |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
60 A |
Tab/Blade |
140 J |
200 kA |
Rated Breaking Capacity at 250 VDC: 20000 A |
Box |
0.81 in (20.57 mm) |
0.81 x 1.59 in (20.57 x 40.39 mm) |
1.59 in (40.39 mm) |
CE; CSA; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
240 V |
150 V |
35 A |
Tab/Blade |
50 J |
200 kA |
Rated Breaking Capacity at 150 VDC: 200000 A |
Box |
0.697 in (17.7 mm) |
0.697 x 1.031 in (17.7 x 26.2 mm) |
1.031 in (26.2 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
10 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
32 V |
0.76 x 0.207 x 0.492 in (19.3 x 5.25 x 12.5 mm) |
0.483 in (12.28 mm) |
UL |
100 °C (212 °F) |
Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
15 A |
Tab/Blade |
-40 °C (-40 °F) |
Silver |
1 kA |
0.43 in (10.92 mm) |
0.15 in (3.81 mm) |
e4 |
32 V |
0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm) |
0.344 in (8.75 mm) |
UL |
100 °C (212 °F) |
Fast |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
150 A |
Tab/Blade |
200 kA |
2.402 in (61 mm) |
600 V |
2.402 x 3.752 in (61 x 95.3 mm) |
3.752 in (95.3 mm) |
UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
15 A |
Tab/Blade |
308 J |
-40 °C (-40 °F) |
1 kA |
30 ms |
270 |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
32 V |
Mini |
0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm) |
0.346 in (8.8 mm) |
UL |
125 °C (257 °F) |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
80 A |
Tab/Blade |
21.5 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
80 A |
Tab/Blade |
-40 °C (-40 °F) |
Silver |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
e4 |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
3 A |
Tab/Blade |
9.4 J |
-40 °C (-40 °F) |
1 kA |
30 ms |
Box |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
0.346 in (8.8 mm) |
UL |
125 °C (257 °F) |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
1.4 kA |
Tab/Blade |
2.7 MJ |
200 kA |
3.425 in (87 mm) |
2.795 in (71 mm) |
Indicator |
3.425 x 2.795 x 2.677 in (87 x 71 x 68 mm) |
2.677 in (68 mm) |
CE; CSA; IEC; UL |
|||||||||||||||||
|
Siemens |
Electric Fuse |
Inline/Holder |
1 KV |
200 A |
Tab/Blade |
-20 °C (-4 °F) |
100 kA |
2.874 in (73 mm) |
2.047 in (52 mm) |
Indicator |
2.874 x 2.047 x 2.047 in (73 x 52 x 52 mm) |
2.047 in (52 mm) |
CCC; CE; UL |
50 °C (122 °F) |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
150 A |
Tab/Blade |
200 kA |
10 s |
Pre Arcing Time: Open within 10 s at 500% Rated Current |
Bulk |
0.063 in (1.61 mm) |
0.379 in (9.63 mm) |
CE; CUL; UL |
Time Delay |
||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
80 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Box |
1.339 in (34 mm) |
RK5 |
600 V |
1.339 x 7.874 in (34 x 200 mm) |
7.874 in (200 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
300 A |
Tab/Blade |
17.6 kJ |
50 kA |
Box |
2 in (50.8 mm) |
2 x 2.84 in (50.8 x 72.14 mm) |
2.84 in (72.136 mm) |
CE; CSA; UL |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
300 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.311 in (33.3 mm) |
300 V |
2.752 in (69.9 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
300 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.311 in (33.3 mm) |
2.752 in (69.9 mm) |
CE; CSA; CUL; UL |
Fast |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
175 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.63 in (41.4 mm) |
J |
600 V |
1.63 x 3 in (41.4 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
40 A |
Tab/Blade |
1.72 kJ |
-40 °C (-40 °F) |
20 kA |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
50 A |
Tab/Blade |
2.74 kJ |
-40 °C (-40 °F) |
20 kA |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
50 A |
Tab/Blade |
2.74 kJ |
-40 °C (-40 °F) |
20 kA |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
40 A |
Tab/Blade |
3.3 kJ |
-40 °C (-40 °F) |
Tin |
1 kA |
80 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm) |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
250 V |
3 A |
Tab/Blade |
200 kA |
0.543 in (13.8 mm) |
0.543 x 1.398 in (13.8 x 35.5 mm) |
1.398 in (35.5 mm) |
||||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.142 x 2.638 in (29 x 67 mm) |
4.606 in (117 mm) |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
125 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.787 in (45.4 mm) |
Indicator |
9.626 in (244.5 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.787 in (45.4 mm) |
Indicator |
9.626 in (244.5 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
100 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
15 A |
Tab/Blade |
365 J |
-55 °C (-67 °F) |
20 kA |
4 m |
Tray |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
25 A |
Tab/Blade |
1.202 kJ |
-55 °C (-67 °F) |
20 kA |
4 m |
Tray |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
30 A |
Tab/Blade |
1.15 kJ |
-40 °C (-40 °F) |
20 kA |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
30 A |
Tab/Blade |
1.15 kJ |
-40 °C (-40 °F) |
20 kA |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
1 KV |
300 A |
Tab/Blade |
17 kJ |
-40 °C (-40 °F) |
Tin |
50 kA |
Bulk |
2.913 in (74 mm) |
1.772 in (45 mm) |
e3 |
0.984 in (25 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
160 A |
Tab/Blade |
6.25 kJ |
150 kA |
1.929 in (49 mm) |
1.181 in (30 mm) |
Indicator |
1.929 x 1.181 x 2.362 in (49 x 30 x 60 mm) |
2.362 in (60 mm) |
CE; DIN 43620; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
32 A |
Tab/Blade |
32 J |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
1.89 in (48 mm) |
1.89 x 0.752 in (48 x 19.1 mm) |
0.752 in (19.1 mm) |
BS 88; CE |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
450 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 450 VDC: 100000 A |
1.13 in (28.7 mm) |
1.13 x 2.63 in (28.7 x 66.8 mm) |
2.63 in (66.8 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 A |
Tab/Blade |
200 kA |
Box |
1.5 in (38.1 mm) |
1.5 x 2.906 in (38.1 x 73.81 mm) |
2.906 in (73.81 mm) |
CE; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
1.5 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
15 A |
Tab/Blade |
314 J |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
|||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
1 KV |
20 A |
Tab/Blade |
804.3 J |
-55 °C (-67 °F) |
20 kA |
4 m |
Tray |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
40 A |
Tab/Blade |
1.72 kJ |
-40 °C (-40 °F) |
20 kA |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
80 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
170 V |
0.563 x 0.877 in (14.3 x 22.27 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
300 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
2.126 in (54 mm) |
Indicator |
2.126 x 3.346 in (54 x 85 mm) |
7.126 in (181 mm) |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
15 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
32 V |
0.76 x 0.207 x 0.492 in (19.3 x 5.25 x 12.5 mm) |
0.483 in (12.28 mm) |
UL |
100 °C (212 °F) |
Fast |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
450 A |
Tab/Blade |
200 kA |
3.984 in (101.2 mm) |
3.984 x 1.78 in (101.2 x 45.2 mm) |
1.78 in (45.2 mm) |
CE; CSA; UL |
Very Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.