Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
10 A |
Tab/Blade |
115 J |
-40 °C (-40 °F) |
1 kA |
80 ms |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm) |
0.74 in (18.8 mm) |
CSA; UL |
125 °C (257 °F) |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
2 A |
Tab/Blade |
1.4 J |
-40 °C (-40 °F) |
1 kA |
100 ms |
Box |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
0.484 in (12.3 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
150 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
3 in (76.2 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
2.126 in (54 mm) |
Indicator |
2.126 x 3.346 in (54 x 85 mm) |
7.126 in (181 mm) |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
350 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
Indicator |
3.236 in (82.2 mm) |
3.236 in (82.2 mm) |
UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
175 A |
Tab/Blade |
200 kA |
1.63 in (41.4 mm) |
J |
600 V |
1.63 x 3 in (41.4 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
60 A |
Tab/Blade |
200 kA |
Box |
0.813 in (20.65 mm) |
0.813 x 2.75 in (20.65 x 69.85 mm) |
2.75 in (69.85 mm) |
CE; UL |
||||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
60 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
60 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
70 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
80 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
800 V |
800 V |
300 A |
Tab/Blade |
52 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 800 VDC: 50000 A |
Bulk |
1.386 in (35.2 mm) |
2.724 in (69.2 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
3 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
1.89 in (48 mm) |
0.748 in (19 mm) |
e3 |
1.88 x 0.75 x 1 in (47.75 x 19.05 x 25.4 mm) |
0.984 in (25 mm) |
CSA; UL |
80 °C (176 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
200 A |
Tab/Blade |
125 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
10 A |
Tab/Blade |
3.8 J |
200 kA |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm) |
1.575 in (40 mm) |
CE; CSA; DIN 43653; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
630 A |
Tab/Blade |
52 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Surface Mount |
125 V |
80 V |
60 A |
Tab/Blade |
2.5 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Very Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.079 in (27.4 mm) |
600 V |
1.657 in (42.1 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
350 A |
Tab/Blade |
14.246 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Bulk |
1.5 in (38.1 mm) |
500 V |
10 ms |
2.093 in (53.16 mm) |
CE; CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
150 V |
1 kA |
Tab/Blade |
520 J |
100 kA |
Rated Breaking Capacity at 150 VDC: 100000 A |
1.5 in (38.1 mm) |
1.5 x 1.252 in (38.1 x 31.8 mm) |
1.252 in (31.8 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
150 V |
1 kA |
Tab/Blade |
520 J |
100 kA |
Rated Breaking Capacity at 150 VDC: 100000 A |
1.5 in (38.1 mm) |
Indicator |
1.5 x 1.252 in (38.1 x 31.8 mm) |
1.252 in (31.8 mm) |
UL |
Very Fast |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
110 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
1.63 in (41.4 mm) |
J |
600 V |
Indicator |
1.63 x 3 in (41.4 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
80 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
90 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
90 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
450 V |
30 A |
Tab/Blade |
993 J |
-40 °C (-40 °F) |
10 kA |
50 ms |
0.406 in (10.3 mm) |
450 V |
1.531 in (38.9 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
300 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
Indicator |
3.236 in (82.2 mm) |
3.236 in (82.2 mm) |
UL |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
300 A |
Tab/Blade |
200 kA |
2.126 in (54 mm) |
7.126 in (181 mm) |
CSA; IEC; UL |
Time Delay |
|||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
550 V |
63 A |
Tab/Blade |
7 kJ |
80 kA |
Box |
0.827 in (21 mm) |
0.827 x 2.303 in (21 x 58.5 mm) |
2.303 in (58.5 mm) |
IEC |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
415 V |
250 V |
40 A |
Tab/Blade |
1.5 kJ |
80 kA |
Rated Breaking Capacity at 250 VDC: 80000 A |
Box |
0.689 in (17.5 mm) |
0.689 x 1.398 in (17.5 x 35.5 mm) |
1.398 in (35.5 mm) |
IEC |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.063 in (27 mm) |
1.063 x 1.657 in (27 x 42.1 mm) |
1.657 in (42.1 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
200 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.079 in (27.4 mm) |
600 V |
1.657 in (42.1 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
60 A |
Tab/Blade |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
Box |
0.35 in (8.9 mm) |
0.35 in (8.9 mm) |
32 V |
0.35 x 0.35 x 0.85 in (8.9 x 8.9 x 21.6 mm) |
0.85 in (21.6 mm) |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
60 A |
Tab/Blade |
15.3 kJ |
-40 °C (-40 °F) |
1 kA |
40 ms |
Box |
1.15 in (29.2 mm) |
0.346 in (8.8 mm) |
0.85 in (21.6 mm) |
UL |
125 °C (257 °F) |
Slow |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
175 A |
Tab/Blade |
100 kA |
80 ms |
Bulk |
1.22 in (31 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
250 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
2 in (50.8 mm) |
3.374 in (85.7 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
80 A |
Tab/Blade |
380 J |
200 kA |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm) |
1.575 in (40 mm) |
CE; CSA; DIN 43653; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
13.5 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
200 A |
Tab/Blade |
1.65 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
250 A |
Tab/Blade |
3.1 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
350 A |
Tab/Blade |
8.5 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
13.5 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 A |
Tab/Blade |
25 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
400 A |
Tab/Blade |
16 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A, Joule Integral Nom at 500 VDC: 83 |
1.5 in (38.1 mm) |
1.5 x 2.091 in (38.1 x 53.1 mm) |
2.091 in (53.1 mm) |
CSA; UL |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
600 A |
Tab/Blade |
92 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A;Joule Integral Nom at 700 VDC: 201 |
2 in (50.8 mm) |
2 x 2.843 in (50.8 x 72.2 mm) |
2.843 in (72.2 mm) |
CSA; UL |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
600 A |
Tab/Blade |
92 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A;Joule Integral Nom at 700 VDC: 201 |
2 in (50.8 mm) |
2 x 2.843 in (50.8 x 72.2 mm) |
2.843 in (72.2 mm) |
CSA; UL |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
75 A |
Tab/Blade |
200 kA |
10 s |
Pre Arcing Time: Open within 10 s at 500% Rated Current |
Bulk |
0.044 in (1.11 mm) |
0.31 in (7.88 mm) |
CE; CUL; UL |
Time Delay |
||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
80 A |
Tab/Blade |
200 kA |
10 s |
Box |
1.06 in (26.924 mm) |
RK5 |
250 V |
1.06 x 5.88 in (26.92 x 149.35 mm) |
5.88 in (149.352 mm) |
CE; CSA; UL |
Time Delay |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.