Tab/Blade Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

KRP-CL-500

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

500 A

Tab/Blade

200 kA

2.402 in (61 mm)

600 V

2.402 x 3.752 in (61 x 95.3 mm)

3.752 in (95.3 mm)

UL

Time Delay

KTU-601

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

601 A

Tab/Blade

200 kA

Box

2.402 in (61 mm)

L

600 V

2.402 x 3.752 in (61 x 95.3 mm)

3.752 in (95.3 mm)

CE; CSA; UL

Fast

LLSRK080

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

1.311 x 7.874 in (33.3 x 200 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

LLSRK080ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

Indicator

1.311 x 7.874 in (33.3 x 200 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

LPJ-600SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

600 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

2.598 in (66 mm)

J

600 V

2.598 x 1.52 in (66 x 38.6 mm)

1.52 in (38.6 mm)

CE; CSA; UL

Time Delay

LPN-RK-110SPI

Cooper Industries

Electric Fuse

Inline/Holder

250 V

250 V

110 A

Tab/Blade

300 kA

LPN-RK

Rated Breaking Capacity at 250 VDC: 100000 A

Box

1.61 in (40.89 mm)

Indicator

1.61 x 7.13 in (40.89 x 181.1 mm)

7.13 in (181.1 mm)

CSA; UL

Time Delay

MIC2025.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

580 J

-40 °C (-40 °F)

1 kA

20 ms

Box

0.358 in (9.1 mm)

0.15 in (3.8 mm)

Micro

0.311 in (7.9 mm)

125 °C (257 °F)

MS7V1-5

Mersen S A

Electric Fuse

Panel Mount

1.5 KV

10 A

Tab/Blade

200 mA

2.461 in (62.5 mm)

1.654 in (42 mm)

Indicator

1.299 in (33 mm)

UL

PC72UD13C500D1A

Mersen S A

Electric Fuse

Inline/Holder

1.25 KV

500 A

Tab/Blade

57.1 kJ

126 kA

Bulk

5.252 in (133.4 mm)

2.323 in (59 mm)

AR

Indicator

2.795 x 2.362 x 2.579 in (71 x 60 x 65.5 mm)

2.559 in (65 mm)

CCC; CE; CSA; CUL; EAC; IEC; UL; VDE

Ultra Fast

SPFJ125.XXL

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

125 A

Tab/Blade

23.529 kJ

20 kA

10 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Midget

3.012 in (76.5 mm)

CE; IEC; UL

V300559

Mersen S A

Electric Fuse

Inline/Holder

1.25 KV

500 A

Tab/Blade

57.1 kJ

126 kA

Bulk

5.252 in (133.4 mm)

2.323 in (59 mm)

AR

Indicator

2.559 in (65 mm)

CCC; CE; CSA; CUL; EAC; IEC; UL; VDE

Ultra Fast

016045

Legrand

Electric Fuse

Inline/Holder

500 V

100 A

Tab/Blade

120 kA

Bulk

2.362 in (60 mm)

1.181 in (30 mm)

NH00

Indicator

2.126 in (54 mm)

EN; IEC; VDE

0287010.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

115 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287015.L

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

340 J

-40 °C (-40 °F)

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287020.PXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

Tab/Blade

520 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287025.PXCN

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

1 kJ

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287030.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.5 kJ

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287030.L

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.5 kJ

-40 °C (-40 °F)

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287030.PXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.5 kJ

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287030.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.5 kJ

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0293575.MXJ

Littelfuse

Electric Fuse

Inline/Holder

32 V

75 A

Tab/Blade

-40 °C (-40 °F)

2 s

0.906 in (23 mm)

0.622 in (15.8 mm)

1.528 in (38.8 mm)

125 °C (257 °F)

0297030.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.23 kJ

-40 °C (-40 °F)

Silver

1 kA

30 ms

1130

0.429 in (10.9 mm)

0.15 in (3.8 mm)

e4

32 V

Mini

0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0297030.WXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.23 kJ

-40 °C (-40 °F)

Tin

1 kA

30 ms

0.429 in (10.9 mm)

0.15 in (3.8 mm)

e3

32 V

Mini

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0298250.ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

250 A

Tab/Blade

389 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0298250ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

250 A

Tab/Blade

389 kJ

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0298300.ZXH

Littelfuse

Electric Fuse

Inline/Holder

32 V

300 A

Tab/Blade

315 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

0298300ZXH

Littelfuse

Electric Fuse

Inline/Holder

32 V

300 A

Tab/Blade

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0498150.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

0498200.MXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

125 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

0527040.UXTHP

Littelfuse

Electric Fuse

Inline/Holder

500 V

40 A

Tab/Blade

1.09 kJ

-55 °C (-67 °F)

10 kA

2 m

Tray

0.293 in (7.45 mm)

0.236 x 1.26 in (6 x 32 mm)

1.352 in (34.35 mm)

CUL; UL

125 °C (257 °F)

0997020WXN

Littelfuse

Electric Fuse

Inline/Holder

58 V

20 A

Tab/Blade

380 J

-40 °C (-40 °F)

Silver

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

Bulk

0.429 in (10.9 mm)

0.14 in (3.55 mm)

e4

0.429 x 0.14 x 0.346 in (10.9 x 3.55 x 8.8 mm)

0.346 in (8.8 mm)

125 °C (257 °F)

0997020.WXN

Littelfuse

Electric Fuse

Inline/Holder

58 V

20 A

Tab/Blade

380 J

-40 °C (-40 °F)

1 kA

30 ms

0.429 in (10.9 mm)

0.15 in (3.8 mm)

58 V

Mini

0.346 in (8.8 mm)

ISO; UL

125 °C (257 °F)

0AKRBK150-BB

Bel Fuse

Electric Fuse

Inline/Holder

500 V

150 A

Tab/Blade

-40 °C (-40 °F)

Tin

50 kA

Bulk

1.929 in (49 mm)

1.457 in (37 mm)

e3

0.945 in (24 mm)

105 °C (221 °F)

0ATO040.VP

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

3.3 kJ

-40 °C (-40 °F)

1 kA

150 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0HEV020.ZXBD

Littelfuse

Electric Fuse

Inline/Holder

450 V

20 A

Tab/Blade

268 J

-40 °C (-40 °F)

10 kA

50 ms

0.406 in (10.3 mm)

450 V

1.531 in (38.9 mm)

CSA; UL

125 °C (257 °F)

0JTD090.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

90 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.126 in (28.6 mm)

2.626 in (66.7 mm)

CSA; UL

Time Delay

0JTD225.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

3.374 in (85.7 mm)

CSA; UL

Time Delay

0JTD225.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

Indicator

3.374 in (85.7 mm)

CSA; UL

Time Delay

0MAX060.XPGLO

Littelfuse

Electric Fuse

Inline/Holder

32 V

60 A

Tab/Blade

-40 °C (-40 °F)

1 kA

40 ms

Bulk

1.15 in (29.21 mm)

0.348 in (8.85 mm)

0.85 in (21.59 mm)

125 °C (257 °F)

Time Delay

0NLS600.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

600 A

Tab/Blade

6.92 MJ

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

3.094 in (78.6 mm)

Indicator

10.374 in (263.5 mm)

CSA; UL

0TLS035.TXL

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.88 in (14.3 x 22.35 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0TLS035.TXLB

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0TLS060.TXMB

Littelfuse

Electric Fuse

Inline/Holder

170 V

60 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

166.7000.520.2

Littelfuse

Electric Fuse

20 A

Tab/Blade

Matte Tin

1 kA

475

0.748 in (19 mm)

0.197 in (5 mm)

Supplemental

e3

80 V

ATO

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

CSA; UL

Time Lag

166.7000.5202

Littelfuse

Electric Fuse

Inline/Holder

80 V

20 A

Tab/Blade

475 J

Tin

Rated Breaking Capacity at 80 VDC: 1000A

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

170M1566

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

690 V

80 A

Tab/Blade

380 J

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

2.126 in (54 mm)

0.827 in (21 mm)

Indicator

2.126 x 0.827 x 1.378 in (54 x 21 x 35 mm)

1.378 in (35 mm)

CE; DIN 43620; IEC; UL

170M2720

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

690 V

350 A

Tab/Blade

13.5 kJ

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 1.89 in (54 x 30 x 48 mm)

1.89 in (48 mm)

CE; IEC; UL

170M3819D

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

400 A

Tab/Blade

115 kJ

200 kA

2.52 in (64 mm)

1.575 in (40 mm)

Indicator

2.52 x 1.575 x 2.677 in (64 x 40 x 68 mm)

2.677 in (68 mm)

CE; CSA; IEC; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.