Eaton Corporation Fuses 1,344

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

C14M50

Eaton Corporation

Electric Fuse

Inline/Holder

400 V

400 V

50 A

End Cap

120 kA

C14

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

CB61F8A-TR1

Eaton Corporation

Electric Fuse

Surface Mount

125 V

125 V

8 A

Wraparound

19.5 J

-55 °C (-67 °F)

Silver with Nickel barrier

100 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current, Rated Breaking Capacity at 125 VDC: 300 A

19.5

Tape And Reel, 7 inch

0.24 in (6.1 mm)

0.101 in (2.57 mm)

e4

125 V

2410

0.24 x 0.101 x 0.101 in (6.1 x 2.57 x 2.57 mm)

0.101 in (2.57 mm)

CQC; CUL; PSE; UL

125 °C (257 °F)

Fast

FNQ-1/10

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

100 mA

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FRN-R-30

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

30 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.56 in (14.22 mm)

RK5

250 V

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

Time Delay

FRN-R-50

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

50 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.81 in (20.57 mm)

RK5

250 V

0.811 x 3 in (20.6 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

FRS-R-50

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

50 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

1.063 in (27 mm)

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CE; CSA; UL

Time Delay

GMC-3-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

19 J

Nickel

100 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; KC; MITI; UL

Time Delay

JKS-175

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

175 A

Tab/Blade

200 kA

1.63 in (41.4 mm)

J

600 V

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Fast

KAC-60

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

60 A

Tab/Blade

200 kA

Box

0.813 in (20.65 mm)

0.813 x 2.75 in (20.65 x 69.85 mm)

2.75 in (69.85 mm)

CE; UL

LP-CC-9

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

150 V

9 A

End Cap

200 kA

Rated Breaking Capacity at 150 VDC: 20000 A

Box

0.394 in (10 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.496 in (38 mm)

CE; CSA; UL

Time Delay

LPJ-3-2/10SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

3.2 A

End Cap

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.811 in (20.6 mm)

J

600 V

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CE; CSA; UL

Time Delay

MDL-1/10-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

42 mJ

Nickel

35 A

0.25 in (6.35 mm)

250 V

0.252 x 1.248 in (6.4 x 31.7 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

MDL-10-R

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

10 A

End Cap

64.4 J

Nickel

1 kA

0.25 in (6.35 mm)

32 V

0.252 x 1.248 in (6.4 x 31.7 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

S506-32-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

32 mA

End Cap

1.4 mJ

Nickel

35 A

0.0051

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; IMQ; SEMKO; UL; VDE

Time Delay

SS-5H-1A-APH

Eaton Corporation

Electric Fuse

Through Hole Mount

300 V

1 A

Pin Wire

7.4 J

-40 °C (-40 °F)

100 A

Ammo Pack

0.335 in (8.5 mm)

0.169 in (4.3 mm)

20 ms

0.335 x 0.169 x 0.329 in (8.5 x 4.3 x 8.35 mm)

0.309 in (7.85 mm)

CCC; CUL; KC; PSE; TUV; UL; VDE

125 °C (257 °F)

Time Delay

TCF3RN

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

3 A

Tab/Blade

-40 °C (-40 °F)

Tin

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

1.89 in (48 mm)

0.748 in (19 mm)

e3

1.88 x 0.75 x 1 in (47.75 x 19.05 x 25.4 mm)

0.984 in (25 mm)

CSA; UL

80 °C (176 °F)

Time Delay

TR1/6125TD5A

Eaton Corporation

Electric Fuse

Surface Mount

125 V

60 V

5 A

Wraparound

34.4 J

50 A

Brick, Pre Arcing Time: Open within 60 s at 200% rated current

Tape And Reel, 7 inch

0.24 in (6.1 mm)

0.106 in (2.69 mm)

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

CSA; UL

Time Delay

VP/ATC-20ID

Eaton Corporation

Electric Fuse

170M1308

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

10 A

Tab/Blade

3.8 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M4416

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

630 A

Tab/Blade

52 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

AGC-5-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

131.5 J

-55 °C (-67 °F)

Nickel

200 A

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.045

Box

0.25 in (6.35 mm)

250 V

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

125 °C (257 °F)

Fast

ANN-60

Eaton Corporation

Electric Fuse

Surface Mount

125 V

80 V

60 A

Tab/Blade

2.5 kA

3.189 in (81 mm)

Indicator

3.189 x 0.874 in (81 x 22.2 mm)

0.874 in (22.2 mm)

CSA; UL

Very Fast

BK/GBB-4-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

4 A

End Cap

Nickel

200 A

Rated Breaking Capacity at 125 VDC: 10000 A

Box

0.25 in (6.35 mm)

250 V

0.236 x 1.26 in (6 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Very Fast

BK1/GMA-500-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

150 mJ

Silver

35 A

Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT

Bag

0.205 in (5.2 mm)

e4

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; UL

Fast

FWP-100G22F

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

500 V

100 A

End Cap

2.065 kJ

200 kA

Bulk

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC; UL

FWP-20A14F

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

20 A

End Cap

26 J

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

26

Box

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; IEC; UL

JKS-30

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

30 A

End Cap

200 kA

Box

0.811 in (20.6 mm)

J

600 V

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CE; CSA; UL

Fast

KLM-20

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

600 V

20 A

End Cap

100 kA

Bulk

0.406 in (10.3 mm)

CC

600 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

KTK-R-1/8

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

125 mA

End Cap

Nickel

200 kA

Box

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

LPJ-110SPI

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

110 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

1.63 in (41.4 mm)

J

600 V

Indicator

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

MDL-2-1/2-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

63.1 J

Nickel

100 A

0.25 in (6.35 mm)

250 V

0.252 x 1.248 in (6.4 x 31.7 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

SC-4

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

170 V

4 A

End Cap

100 kA

Rated Breaking Capacity at 170 VDC: 10000 A

Box

0.406 in (10.3 mm)

G

600 V

0.406 x 1.31 in (10.3 x 33.27 mm)

1.31 in (33.27 mm)

CSA; UL

Fast

TR2-S505H-V-3.15-R

Eaton Corporation

Electric Fuse

Through Hole Mount

600 V

400 V

3.15 A

Pin Wire

43.55 J

Tin

100 A

Rated Breaking Capacity at 400 VDC: 1500 A

Tape And Reel

0.218 in (5.54 mm)

e3

0.218 x 0.831 in (5.54 x 21.1 mm)

0.831 in (21.1 mm)

PSE/JET; UL

Time Delay

63D33R

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

63 A

End Cap

26.5 kJ

50 kA

Bulk

1.063 in (27 mm)

DIII

1.969 in (50 mm)

DIN 49515; IEC60269

Ultra Fast

BK-S505H-V-3.15-R

Eaton Corporation

Electric Fuse

Through Hole Mount

600 V

400 V

3.15 A

Pin Wire

43.55 J

Tin

100 A

Rated Breaking Capacity at 400 VDC: 1500 A

Box

0.218 in (5.54 mm)

e3

0.218 x 0.831 in (5.54 x 21.1 mm)

0.831 in (21.1 mm)

PSE/JET; UL

Time Delay

CCPLP-2-30CC-P

Eaton Corporation

Electric Fuse

Panel Mount

600 V

600 V

30 A

-20 °C (-4 °F)

200 kA

3.831 in (97.3 mm)

2.244 in (57 mm)

CC

600 V

0.394 x 1.496 in (10 x 38 mm)

3.504 in (89 mm)

CE

90 °C (194 °F)

CEO63

Eaton Corporation

Electric Fuse

Inline/Holder

550 V

63 A

Tab/Blade

7 kJ

80 kA

Box

0.827 in (21 mm)

0.827 x 2.303 in (21 x 58.5 mm)

2.303 in (58.5 mm)

IEC

ESD40

Eaton Corporation

Electric Fuse

Inline/Holder

415 V

250 V

40 A

Tab/Blade

1.5 kJ

80 kA

Rated Breaking Capacity at 250 VDC: 80000 A

Box

0.689 in (17.5 mm)

0.689 x 1.398 in (17.5 x 35.5 mm)

1.398 in (35.5 mm)

IEC

GLR-3

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

3 A

End Cap

10 kA

0.626 in (15.9 mm)

300 V

0.626 in (15.9 mm)

CE; CSA; UL

Fast

MAX-60

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

60 A

Tab/Blade

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

Box

0.35 in (8.9 mm)

0.35 in (8.9 mm)

32 V

0.35 x 0.35 x 0.85 in (8.9 x 8.9 x 21.6 mm)

0.85 in (21.6 mm)

Fast

SP/LPJ-60SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

60 A

End Cap

Silver

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.063 in (27 mm)

e4

1.063 x 2.374 in (27 x 60.3 mm)

2.374 in (60.3 mm)

CE; CSA; UL

Time Delay

TR/3216FF3-R

Eaton Corporation

Electric Fuse

Surface Mount

32 V

63 V

3 A

Wraparound

275 mJ

-55 °C (-67 °F)

50 A

5 s

Pre Arcing Time: Open within 5 s at 250% Rated Current

0.27

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

63 V

1206

0.126 x 0.063 x 0.035 in (3.2 x 1.6 x 0.89 mm)

0.035 in (0.89 mm)

AEC-Q200; CSA; UL

125 °C (257 °F)

Fast

170M1316

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

80 A

Tab/Blade

380 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M4412

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

400 A

Tab/Blade

13.5 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M4458

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

200 A

Tab/Blade

1.65 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M4459

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

250 A

Tab/Blade

3.1 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M4461

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

350 A

Tab/Blade

8.5 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M4462

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

400 A

Tab/Blade

13.5 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.