Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

GLR-2

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

2 A

End Cap

10 kA

0.626 in (15.9 mm)

300 V

0.626 in (15.9 mm)

CE; CSA; UL

Fast

JJS-350

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

350 A

Tab/Blade

200 kA

3.626 in (92.1 mm)

3.626 x 1.736 in (92.1 x 44.1 mm)

1.736 in (44.1 mm)

CE; CSA; UL

Very Fast

KGJ-75

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

75 A

End Cap

200 kA

KGJ

UL

Fast

KLM-1

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

600 V

1 A

End Cap

100 kA

Bulk

0.406 in (10.3 mm)

CC

600 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

KTK-6

Eaton Corporation

Electric Fuse

6 A

End Cap

100 kA

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Fast

KTS-R-75

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

75 A

Tab/Blade

-40 °C (-40 °F)

200 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Box

1.339 in (34 mm)

RK1

600 V

1.339 x 7.874 in (34 x 200 mm)

7.874 in (200 mm)

CE; CSA; UL

85 °C (185 °F)

Fast

MDL-2-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 V

2.5 A

End Cap

63.1 J

35 A

0.25 in (6.35 mm)

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Time Delay

TCF45RN

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

45 A

Tab/Blade

-40 °C (-40 °F)

Tin

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

2.126 in (54 mm)

0.984 in (25 mm)

e3

2.13 x 1 x 1.125 in (54.1 x 25.4 x 28.58 mm)

1.142 in (29 mm)

CSA; UL

80 °C (176 °F)

Time Delay

TR2/1025FA1.5-R

Eaton Corporation

Electric Fuse

Surface Mount

250 V

125 V

1.5 A

End Cap

1.46 J

50 A

Rated Breaking Capacity at 125 VDC: 50 A

Tape And Reel

0.405 in (10.29 mm)

0.109 in (2.77 mm)

250 V

0.405 x 0.109 x 0.109 in (10.29 x 2.77 x 2.77 mm)

0.109 in (2.77 mm)

CSA; UL

Fast

TR2/1025FA15-R

Eaton Corporation

Electric Fuse

Surface Mount

250 V

60 V

15 A

End Cap

1.451 kJ

50 A

Rated Breaking Capacity at 60 VDC: 50 A

Tape And Reel

0.405 in (10.29 mm)

0.109 in (2.77 mm)

250 V

0.405 x 0.109 x 0.109 in (10.29 x 2.77 x 2.77 mm)

0.109 in (2.77 mm)

CSA; UL

Fast

XEV10-20-1P

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

761 J

-40 °C (-40 °F)

20 kA

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

125 °C (257 °F)

12CT

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

12 A

Tab/Blade

10 J

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

2.157 in (54.8 mm)

2.157 x 0.343 in (54.8 x 8.7 mm)

0.343 in (8.7 mm)

BS 88; CE

170M1761

Eaton Corporation

Electric Fuse

Inline/Holder

800 V

315 A

Tab/Blade

12.5 kJ

50 kA

2.126 in (54 mm)

1.429 in (36.3 mm)

0.945 in (24 mm)

UL

170M2615

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

125 A

Tab/Blade

1 kJ

200 kA

Box

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm)

2.008 in (51 mm)

CE; CSA; DIN 43653; IEC; UL

170M4467

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 A

Tab/Blade

69.5 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M8554D

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

1.25 kA

Tab/Blade

2.15 MJ

200 kA

3.425 in (87 mm)

2.795 in (71 mm)

Indicator

3.425 x 2.795 x 2.677 in (87 x 71 x 68 mm)

2.677 in (68 mm)

CE; CSA; IEC; UL

35FE

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

35 A

Tab/Blade

33 J

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

1.89 in (48 mm)

1.89 x 0.752 in (48 x 19.1 mm)

0.752 in (19.1 mm)

BS 88; CE

ANN-250

Eaton Corporation

Electric Fuse

Surface Mount

125 V

80 V

250 A

Tab/Blade

2.5 kA

3.189 in (81 mm)

Indicator

3.189 x 0.874 in (81 x 22.2 mm)

0.874 in (22.2 mm)

CSA; UL

Very Fast

BBS-4

Eaton Corporation

Electric Fuse

4 A

End Cap

10 kA

0.41 in (10.41 mm)

600 V

0.41 x 1.38 in (10.41 x 35.05 mm)

1.38 in (35.05 mm)

CE, CSA, UL

Fast

BK/C520-3-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

6.1 J

Nickel

100 A

Box

0.205 in (5.2 mm)

250 V

0.197 x 0.591 in (5 x 15 mm)

0.205 x 0.591 in (5.2 x 15 mm)

0.591 in (15 mm)

CSA; UL

Fast

BK/KTK-R-5

Eaton Corporation

Electric Fuse

5 A

End Cap

200 kA

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

BK1/S506-160-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

160 mA

End Cap

93 mJ

Nickel

35 A

0.093

Bag

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; IMQ; SEMKO; UL; VDE

Time Delay

BKPCC-2-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

450 V

2 A

Pin Wire

200 mJ

50 A

10 s

Rated Breaking Capacity at 450 VDC: 300 A

Box

250 V

0.35 x 0.184 x 0.345 in (8.89 x 4.67 x 8.76 mm)

CUL; UL

Fast

C310T-2-R-TR1

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

2 A

Pin Wire

27.2 J

Tin/Copper

35 A

27.2

Tape And Reel

0.157 in (4 mm)

e2

250 V

0.157 x 0.453 in (4 x 11.5 mm)

0.453 in (11.5 mm)

CQC; IEC; KTL; UL; VDE

Time Delay

CGL-200

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

200 A

Tab/Blade

200 kA

1.5 in (38.1 mm)

1.5 x 3 in (38.1 x 76.2 mm)

3 in (76.2 mm)

CSA

FNA-1/10

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

35 A

0.406 in (10.31 mm)

250 V

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Time Lag

FNA-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

35 A

FNA

Box

0.817 in (20.75 mm)

Indicator

0.817 x 1.5 in (20.75 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FNA-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

35 A

0.406 in (10.31 mm)

250 V

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Time Lag

FNA-1/8

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

35 A

0.406 in (10.31 mm)

250 V

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Time Lag

FNA-12

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

12 A

End Cap

10 kA

1.5 in (38.1 mm)

0.817 in (20.75 mm)

125 V

0.406 x 0.817 x 1.5 in (10.31 x 20.75 x 38.1 mm)

0.406 in (10.31 mm)

CSA, UL

Time Lag

FNM-2-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

2.25 A

End Cap

100 A

Box

0.406 in (10.3 mm)

250 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FWH-001A6F

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

1 A

End Cap

2 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.4

Box

0.248 in (6.3 mm)

500 V

0.248 x 1.26 in (6.3 x 32 mm)

0.252 x 1.252 in (6.4 x 31.8 mm)

1.26 in (32 mm)

CE; CSA; UL

Fast

FWP-100A22F

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

100 A

End Cap

1.1 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.874 in (22.2 mm)

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

IEC; UL

FWP-50G22FI

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

500 V

50 A

End Cap

273 J

200 kA

Bulk

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

Indicator

2.283 in (58 mm)

IEC; UL

GDB-3.15A

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

13 J

35 A

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

UL; VDE

Fast

GLR-15

Eaton Corporation

Electric Fuse

Inline/Holder

300 V

15 A

End Cap

10 kA

0.626 in (15.9 mm)

300 V

0.626 in (15.9 mm)

CE; UL

Fast

LKN-60

Eaton Corporation

Electric Fuse

MDL-1-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

11.498 J

Nickel

35 A

0.25 in (6.35 mm)

250 V

0.252 x 1.248 in (6.4 x 31.7 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

NITD32

Eaton Corporation

Electric Fuse

Inline/Holder

550 V

32 A

Tab/Blade

710 J

80 kA

Box

0.539 in (13.7 mm)

0.539 x 1.362 in (13.7 x 34.6 mm)

1.362 in (34.6 mm)

IEC

NOS-4

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

4 A

End Cap

50 kA

Box

0.81 in (20.57 mm)

K5

600 V

0.81 x 5 in (20.57 x 127 mm)

5 in (127 mm)

CE; CSA; UL

PTS12066V100

Eaton Corporation

Electric Fuse

Surface Mount

6 V

1 A

Wraparound

-40 °C (-40 °F)

Tin Over Nickel

100 A

300 ms

Tape And Reel, 7 inch

0.138 in (3.5 mm)

0.071 in (1.8 mm)

e3

6 V

210 mΩ

1206

0.035 in (0.88 mm)

TUV; UL

85 °C (185 °F)

Fast

SF100X1000HP

Eaton Corporation

Electric Fuse

T-1-1/8

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

1.125 A

10 kA

T

Box

CE; CSA; UL

Time Delay

T-10

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

10 A

10 kA

Box

CE; CSA; UL

Time Delay

T-15

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

15 A

10 kA

Box

CE; CSA; UL

Time Delay

T-8

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

8 A

10 kA

Box

CE; CSA; UL

Time Delay

T-9

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

9 A

10 kA

Box

CE; CSA; UL

Time Delay

TR2/C515-125-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

125 mA

Pin Wire

101 mJ

-55 °C (-67 °F)

Tin

35 A

3 s

Pre Arcing Time: Open within 3 s at 200% Rated Current

Tape And Reel

0.217 in (5.5 mm)

e3

250 V

3 s

0.197 x 0.591 in (5 x 15 mm)

0.217 x 0.598 in (5.5 x 15.2 mm)

0.598 in (15.2 mm)

CSA, UL

85 °C (185 °F)

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.