Part | RoHS | Manufacturer | Connector Accessory Type | Connector Side-1 | Connector Side-2 | Rated Voltage | Rated Current | Shielding | Approvals (V) | Cross Section Area | Finish Thickness | Conductor Material | Construction | Minimum Wire Size | Jacket Material | Terminal Type | Resistance | Conductor Finish | MIL Conformity | Maximum Wire Size | Insulator Material | Maximum Operating Temperature | DIN Conformity | Application | Cable Types | IEC Conformity | Minimum Operating Temperature | Wire Gauge (AWG) | Design | Diameter | No. of Conductors | Mounting Style | Additional Features | Material | Mounting Option-2 | Length | Mounting Option-1 | Wire & Cable Name | Stranding | Rated DC Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Helukabel |
WIRE AND CABLE |
NO |
POLYETHYLENE |
NO |
70 Cel |
NO |
AERIAL CABLES FOR FREELY SUSPENDED INSTALLATION ON POSTS |
NO |
-25 Cel |
21.6 mm |
144 |
COMMUNICATION CABLE |
||||||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
1.3 A |
NO |
NEMA; UL |
.0509 mm2 |
COPPER ALLOY |
STRANDED |
SILVER |
YES |
TETRAFLUOROETHYLENE |
105 Cel |
NO |
NO |
30 |
.812 mm |
1 |
STANDARD: MIL-W-16878/4 |
FLEXIBLE CORD AND FIXTURE WIRE |
7X38 |
|||||||||||||||||||
|
Belden |
WIRE AND CABLE |
1.8 A |
NO |
UL |
COPPER |
STRANDED |
SILVER |
TFE |
28 |
.889 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X36 |
|||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
1.8 A |
NO |
UL |
COPPER |
STRANDED |
SILVER |
TFE |
28 |
.889 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X36 |
|||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
NO |
UL |
COPPER |
STRANDED |
SILVER |
TFE |
24 |
1.1176 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X36 |
|||||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
4.5 A |
NO |
COPPER |
STRANDED |
.05 ohm |
SILVER |
YES |
TFE |
200 Cel |
NO |
NO |
-70 Cel |
22 |
1.27 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
4.5 A |
NO |
MIL, UL |
COPPER |
STRANDED |
.052 ohm |
SILVER |
TFE |
200 Cel |
-70 Cel |
22 |
1.27 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
6.5 A |
NO |
UL |
COPPER |
STRANDED |
.03 ohm |
SILVER |
TFE |
200 Cel |
-70 Cel |
20 |
1.473 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
4.5 A |
NO |
MIL, UL |
COPPER |
STRANDED |
.0517 ohm |
SILVER |
TFE |
200 Cel |
-70 Cel |
22 |
1.524 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
4.5 A |
NO |
MIL, UL |
COPPER |
STRANDED |
.0517 ohm |
SILVER |
TFE |
200 Cel |
-70 Cel |
22 |
1.524 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
13 A |
NO |
MIL; NEMA; UL |
1.31 mm2 |
COPPER |
STRANDED |
.0131 ohm |
SILVER |
YES |
TETRAFLUOROETHYLENE |
200 Cel |
NO |
NO |
-70 Cel |
16 |
2.235 mm |
1 |
STANDARD: MIL-W-16878/5 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X29 |
||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
2.9 A |
NO |
UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
.051 ohm |
POLYVINYL CHLORIDE |
60 Cel |
-20 Cel |
22 |
4.318 mm |
2 |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
||||||||||||||||||||||
|
Quail Electronics |
CABLE ASSEMBLY |
CEE 7/7 |
IEC-60320-C13 |
250 V |
10 A |
NO |
CE; KC |
1 mm2 |
NO |
NO |
NO |
17 |
3 |
2.5 mm |
POWER CABLE |
||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
NO |
MIL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
24 |
1.473 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
7X32 |
||||||||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.205 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
.095 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-10 Cel |
24 |
5.21 mm |
5 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
10X34 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.205 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
.095 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-10 Cel |
24 |
5.21 mm |
5 |
152.4 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
10X34 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.205 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
.095 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-10 Cel |
24 |
5.21 mm |
5 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
10X34 |
|||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
566 V |
3.9 A |
NO |
UL |
TINNED COPPER |
STRANDED |
PVC |
NO |
POLYPROPYLENE |
105 Cel |
NO |
NO |
-40 Cel |
20 |
8.534 mm |
8 |
COMMUNICATION AND CONTROL CABLE |
7X28 |
||||||||||||||||||||
|
Fiberstore |
CABLE ASSEMBLY |
LC |
LC |
NO |
CE |
PVC |
NO |
70 Cel |
NO |
NO |
-20 Cel |
2 mm |
COMMUNICATION CABLE |
||||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
5000 V |
8 A |
NO |
UL |
.823 mm2 |
TINNED COPPER |
STRANDED |
.021 ohm |
NO |
RUBBER |
90 Cel |
NO |
NO |
-40 Cel |
18 |
3.66 mm |
1 |
152.4 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
65X36 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
2.081 mm2 |
COPPER ALLOY |
STRANDED |
.009 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
14 |
2.69 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
41X30 |
||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
20 A |
NO |
CSA; UL |
TINNED COPPER |
STRANDED |
.019 ohm |
POLYVINYL CHLORIDE |
105 Cel |
INTERNAL WIRING OF ELECTRICAL, ELECTRONIC EQIPMENT |
18 |
2.794 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
16X30 |
||||||||||||||||||||||
|
Molex |
CABLE ASSEMBLY |
QF50 |
QF50 |
NO |
UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
28 |
26 |
|||||||||||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
NO |
.326 mm2 |
TINNED COPPER |
SOLID |
NO |
PVC |
NO |
NO |
22 |
1 |
.025 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X22 |
|||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
1.5 A |
NO |
CE; CSA; UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
.051 ohm |
POLYVINYL CHLORIDE |
80 Cel |
22 |
8.76 mm |
20 |
COMMUNICATION AND CONTROL CABLE |
7X30 |
|||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
2.2 A |
NO |
UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
.059 ohm |
POLYVINYL CHLORIDE |
80 Cel |
-30 Cel |
24 |
3.962 mm |
2 |
FLEXIBLE CORD AND FIXTURE WIRE |
7X32 |
||||||||||||||||||||||
|
Cicoil |
WIRE AND CABLE |
18000 V |
11 A |
NO |
CE; CSA; UL |
TINNED COPPER |
STRANDED |
NO |
165 Cel |
NO |
AEROSPACE, FESTOON SYSTEMS, ROBOTICS, MEDICAL,OIL DRILLING |
NO |
-65 Cel |
22 |
4 |
DIAMETER OF INDIVIDUAL CONDUCTOR IS 2.794 MM |
FLAT FLEXIBLE CABLE |
||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
300 V |
NO |
FLAT |
POLYVINYL CHLORIDE |
105 Cel |
-20 Cel |
28 |
34 |
FLAT RIBBON CABLE |
|||||||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
3 A |
NO |
UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
.052 ohm |
PP |
90 Cel |
-20 Cel |
22 |
3.683 mm |
3 |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
||||||||||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.5 A |
NO |
UL |
.03 mm2 |
COPPER ALLOY |
FLAT |
.73 ohm |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
32 |
6 |
.051 mm |
FLAT CABLE |
|||||||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.5 A |
NO |
UL |
.03 mm2 |
COPPER ALLOY |
FLAT |
.73 ohm |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
32 |
27 |
.305 mm |
FLAT CABLE |
|||||||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.5 A |
NO |
UL |
.03 mm2 |
COPPER ALLOY |
FLAT |
.73 ohm |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
32 |
29 |
.051 mm |
FLAT CABLE |
|||||||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.5 A |
NO |
UL |
.03 mm2 |
COPPER ALLOY |
FLAT |
.73 ohm |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
32 |
31 |
.03 mm |
FLAT CABLE |
|||||||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.5 A |
NO |
UL |
.03 mm2 |
COPPER ALLOY |
FLAT |
.73 ohm |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
32 |
31 |
.305 mm |
FLAT CABLE |
|||||||||||||||||||
|
Molex |
CABLE ASSEMBLY |
NO |
28 |
||||||||||||||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
51 A |
NO |
CE; CSA; UL |
TINNED COPPER |
STRANDED |
.005 ohm |
POLYVINYL CHLORIDE |
105 Cel |
INTERNAL WIRING OF ELECTRICAL, ELECTRONIC EQIPMENT |
-25 Cel |
12 |
4.013 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
65X30 |
|||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
51 A |
NO |
CE; CSA; UL |
TINNED COPPER |
STRANDED |
.005 ohm |
POLYVINYL CHLORIDE |
105 Cel |
-25 Cel |
12 |
4.01 mm |
1 |
76.2 mm |
COMMUNICATION CABLE |
65X30 |
||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
TINNED COPPER |
STRANDED |
.031 ohm |
POLYVINYL CHLORIDE |
105 Cel |
20 |
1.75 mm |
1 |
30.48 mm |
COMMUNICATION CABLE |
7X28 |
||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
TINNED COPPER |
STRANDED |
.031 ohm |
POLYVINYL CHLORIDE |
105 Cel |
20 |
1.75 mm |
1 |
30.48 mm |
COMMUNICATION CABLE |
7X28 |
||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
TINNED COPPER |
STRANDED |
.031 ohm |
POLYVINYL CHLORIDE |
105 Cel |
20 |
1.75 mm |
1 |
304.8 mm |
COMMUNICATION CABLE |
7X28 |
||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.518 mm2 |
COPPER ALLOY |
STRANDED |
NO |
POLYVINYL CHLORIDE |
80 Cel |
NO |
NO |
20 |
1.447 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X28 |
|||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
.38 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
22 AWG |
120 Cel |
EQUIPMENT WIRE |
SPEC 99M |
-55 Cel |
22 |
1.2 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
.24 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
24 AWG |
120 Cel |
EQUIPMENT WIRE |
SPEC 99M |
-55 Cel |
24 |
1.05 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X36 |
||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
50 V |
NO |
.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYLIDENE DIFLUORIDE |
.037 ohm |
NO |
0 AWG |
POLYALKENE |
150 Cel |
NO |
PRIMARY WIRE |
NO |
-40 Cel |
20 |
1.5 mm |
1 |
10000 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X0.19 |
|||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
50 V |
NO |
.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYLIDENE DIFLUORIDE |
.037 ohm |
NO |
0 AWG |
POLYALKENE |
150 Cel |
NO |
PRIMARY WIRE |
NO |
-40 Cel |
20 |
1.5 mm |
1 |
10000 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X0.19 |
|||||||||||||||||
Anixter |
WIRE AND CABLE |
300 V |
NO |
UL |
COPPER |
STRANDED |
PVC |
TIN |
NO |
PVC |
105 Cel |
NO |
CABLE TRY INSTALLATIONS, INTERCOM SYSTEM, BURGLAR ALARMS |
NO |
-20 Cel |
16 |
6.17 mm |
2 |
POWER LIMITED |
19X0.0117 |
||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
150 V |
NO |
CUL; UL |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
POLYVINYL CHLORIDE |
80 Cel |
NO |
NO |
-20 Cel |
28 |
10 |
3M, DIAMETER OF INDIVIDUAL CONDUCTOR IS 1.07 MM |
FLAT CABLE |
7X36 |
||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
CUL, UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
105 Cel |
-20 Cel |
28 |
14 |
FLAT FLEXIBLE CABLE |
7X36 |
Electrical wires and cables are conductive materials that are used to transmit electrical power and signals from one location to another. They are an essential component of any electrical system, ranging from small electronic devices to large industrial installations.
Electrical wires are typically made of a conductive material, such as copper or aluminum, that is coated in an insulating material to prevent electrical leakage or short-circuits. They are available in various gauges and thicknesses to handle different levels of electrical current and resistance.
Cables, on the other hand, are bundles of two or more electrical wires that are wrapped in an outer jacket for protection and insulation. They are designed for specific purposes, such as transmitting high-speed data, audio, or video signals, and can be shielded or unshielded to reduce electromagnetic interference.
Both electrical wires and cables are critical components of modern electrical systems and are used in a wide range of applications, including residential and commercial buildings, automotive and aerospace industries, telecommunications, and more.