500 V Fuses 931

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

C14G40

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

40 A

End Cap

120 kA

C14

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

FNQ-15

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

15 A

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

50NHG000B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

50 A

Tab/Blade

5.9 kJ

120 kA

Box

1.929 in (49 mm)

0.827 in (21 mm)

NH000

Indicator

1.614 in (41 mm)

CE; DIN; IEC; VDE

FNQ-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 mA

End Cap

10 kA

Bulk

0.406 in (10.3 mm)

500 V

1.5 in (38.1 mm)

CSA; UL

Time Delay

FNQ-12

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

12 A

End Cap

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

35NHG000B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

35 A

Tab/Blade

2.4 kJ

120 kA

Box

1.929 in (49 mm)

0.827 in (21 mm)

NH000

Indicator

1.614 in (41 mm)

CE; DIN; IEC; VDE

S218194

Mersen S A

Electric Fuse

Inline/Holder

500 V

250 V

10 A

End Cap

120 kA

Rated Breaking Capacity at 250 VDC: 100000 A

0.402 in (10.2 mm)

1.496 in (38 mm)

CE

8020.5078

Schurter Ag

Electric Fuse

Inline/Holder

500 V

400 V

10 A

End Cap

220 J

-40 °C (-40 °F)

1.5 kA

220

Bulk

0.25 in (6.35 mm)

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL, UL

85 °C (185 °F)

Very Fast

20NHG000B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

20 A

Tab/Blade

490 J

120 kA

Box

1.929 in (49 mm)

0.827 in (21 mm)

NH000

Indicator

1.614 in (41 mm)

CE; DIN; IEC; VDE

8020.5021

Schurter Ag

Electric Fuse

Inline/Holder

500 V

400 V

10 A

End Cap

700 J

-40 °C (-40 °F)

Nickel

1.5 kA

Rated Breaking Capacity at 400 VDC: 1000 A

Bulk

0.25 in (6.35 mm)

10 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

FNQ-7

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

7 A

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FWH-300A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

300 A

Tab/Blade

9.8 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

1.5 in (38.1 mm)

1.5 x 2.09 in (38.1 x 53.09 mm)

2.09 in (53.09 mm)

CE; CSA; UL

FWH-30A14F

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

30 A

End Cap

232 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

FWH-700A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

700 A

Tab/Blade

55 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

2.5 in (63.5 mm)

2.5 x 2.09 in (63.5 x 53.09 mm)

2.09 in (53.09 mm)

CE; CSA; UL

FNQ-3-2/10

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

3.2 A

End Cap

Nickel

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

63NHG000B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

63 A

Tab/Blade

6.3 kJ

120 kA

Box

1.929 in (49 mm)

0.827 in (21 mm)

NH000

Indicator

1.614 in (41 mm)

CE; DIN; IEC; VDE

FNQ-10

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

10 A

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

C10G1

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

1 A

End Cap

120 kA

C10

0.394 in (10 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

100NHG000B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

100 A

Tab/Blade

18.1 kJ

120 kA

Box

1.929 in (49 mm)

0.827 in (21 mm)

NH000

Indicator

1.614 in (41 mm)

CE; DIN; IEC; VDE

FWH-200B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

200 A

Tab/Blade

1.9 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

1.156 in (29.36 mm)

1.156 x 1.836 in (29.36 x 46.63 mm)

1.836 in (46.63 mm)

CE; CSA; UL

FWH-350A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

350 A

Tab/Blade

14.5 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

1.5 in (38.1 mm)

1.5 x 2.09 in (38.1 x 53.09 mm)

2.09 in (53.09 mm)

CE; CSA; UL

FNQ-1

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

1 A

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

FNQ-3-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

3.5 A

End Cap

Nickel

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

L50QS100.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

100 A

Tab/Blade

905 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1 in (25.4 mm)

500 V

10 ms

2.125 in (53.98 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

172530.2

Siba

Electric Fuse

Inline/Holder

500 V

2 A

End Cap

80 A

Bulk

0.205 in (5.2 mm)

500 V

5 ms

0.197 x 1.181 in (5 x 30 mm)

1.181 in (30 mm)

Very Fast

FWH-3.15A6F

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

3.15 A

End Cap

7.7 J

50 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.252 in (6.4 mm)

0.252 x 1.252 in (6.4 x 31.8 mm)

1.252 in (31.8 mm)

CE; CSA; UL

7012540.16

Siba

Electric Fuse

Inline/Holder

500 V

16 A

End Cap

31 J

50 kA

Bulk

0.25 in (6.35 mm)

1 ms

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

Very Fast

FNQ-5

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

5 A

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

KTK-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

500 mA

End Cap

Nickel

100 kA

KTK

Box

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

0FLQ010.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

10 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

Z219235

Mersen S A

Electric Fuse

Inline/Holder

500 V

250 V

50 A

End Cap

120 kA

Rated Breaking Capacity at 250 VDC: 100000 A

0.563 in (14.3 mm)

2.008 in (51 mm)

CE; IEC60269-1; IEC60269-2

04773.15MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

400 V

3.15 A

Pin Wire

50.109 J

-55 °C (-67 °F)

Tin

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 1500 A

Bulk

0.217 in (5.5 mm)

e3

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.846 in (21.5 mm)

PSE; VDE

125 °C (257 °F)

Time Lag

W301089

Mersen S A

Electric Fuse

Panel Mount

500 V

2.25 kA

Threaded

1.25 MJ

200 kA

Bulk

1.992 in (50.6 mm)

2.874 in (73 mm)

33

Indicator

3.091 in (78.5 mm)

CCC; CE; CSA; EAC; IEC; UL; VDE

Ultra Fast

0FLQ025.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

25 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0FLQ02.5T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2.5 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FNQ-3

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

3 A

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

189140.1,6

Siba

Electric Fuse

Inline/Holder

500 V

400 V

1.6 A

End Cap

5.2 J

1.5 kA

Bulk

0.25 in (6.35 mm)

10 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

UL

Time Lag

189140.16

Siba

Electric Fuse

Inline/Holder

500 V

300 V

16 A

End Cap

2.5 kJ

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

UL

Time Lag

0514005.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

5 A

End Cap

6.14 J

-55 °C (-67 °F)

5 kA

2 m

Bulk

0.25 in (6.35 mm)

3AB

1.25 in (31.75 mm)

125 °C (257 °F)

Fast

80NHG000B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

80 A

Tab/Blade

9.8 kJ

120 kA

Box

1.929 in (49 mm)

0.827 in (21 mm)

NH000

Indicator

1.614 in (41 mm)

CE; DIN; IEC; VDE

592005S

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

5 A

End Cap

Silver

592

e4

C14M25

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

25 A

End Cap

120 kA

C14

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

189140.1

Siba

Electric Fuse

Inline/Holder

500 V

400 V

1 A

End Cap

1.4 J

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

10 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Time Lag

C10G10

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

10 A

End Cap

120 kA

0.394 in (10 mm)

500 V

5AG

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

FWH-002A6F

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

2 A

End Cap

1.3 J

50 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.252 in (6.4 mm)

0.252 x 1.252 in (6.4 x 31.8 mm)

1.252 in (31.8 mm)

CE; CSA; UL

FWH-450A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

450 A

Tab/Blade

24.7 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

2 in (50.8 mm)

2 x 2.09 in (50.8 x 53.09 mm)

2.09 in (53.09 mm)

CE; CSA; UL

FWH-500A

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

500 A

Tab/Blade

29.2 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

2 in (50.8 mm)

2 x 2.09 in (50.8 x 53.09 mm)

2.09 in (53.09 mm)

CE; CSA; UL

63D33Q

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

63 A

End Cap

26.5 kJ

50 kA

Bulk

1.063 in (27 mm)

DIII

1.969 in (50 mm)

DIN 49515; IEC60269

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.