500 V Fuses 931

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0913663

Phoenix Contact

Electric Fuse

Inline/Holder

500 V

500 V

25 A

End Cap

-60 °C (-76 °F)

0.866 in (22 mm)

GG

500 V

1.969 in (50 mm)

85 °C (185 °F)

KLH150

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

150 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

1.22 in (31 mm)

1.22 x 2.126 in (31 x 54 mm)

2.126 in (54 mm)

CSA; UL

Fast

7945816034

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.25 A

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

592015S

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

15 A

End Cap

Silver

592

e4

NH00CG32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

CY10X38M1

Littelfuse

Electric Fuse

Inline/Holder

500 V

1 A

End Cap

120 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Time Lag

FLQ15/100

Littelfuse

Electric Fuse

Inline/Holder

500 V

150 mA

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Slow

7945816073

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

30 A

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

NH00M4

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

4 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

L50S20

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Fast

FLQ010

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

10 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

097706.3MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

450 V

6.3 A

Pin Wire

188 J

-55 °C (-67 °F)

100 A

Rated Breaking Capacity at 450 VDC: 200 A

188

Bulk

0.228 in (5.8 mm)

500 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.886 in (22.5 mm)

CE; PSE; SEMKO

125 °C (257 °F)

Time Lag

051412.5MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

12.5 A

End Cap

114 J

-55 °C (-67 °F)

5 kA

2 m

Bulk

0.25 in (6.35 mm)

3AB

1.25 in (31.75 mm)

125 °C (257 °F)

Fast

FLQ04.5T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

4.5 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

NH00M25

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

25 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

0FLQ01.6T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.6 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

592006

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

6 A

End Cap

Nickel

592

NH00CM100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH1CG125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

7945816051

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

3.5 A

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

592.300

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

300 mA

End Cap

Nickel

592

L50S100

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

1 in (25.4 mm)

1 x 2.126 in (25.4 x 54 mm)

2.126 in (54 mm)

CSA; UL

Fast

LA50QS225-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

225 A

Tab/Blade

25 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

1.5 in (38.1 mm)

500 V

1.5 x 2.091 in (38.1 x 53.1 mm)

2.091 in (53.1 mm)

CSA; UL

Fast

0504020.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

420 V

20 A

End Cap

760 J

-60 °C (-76 °F)

200 A

Bulk

0.25 in (6.35 mm)

120 s

3AG

0.049 in (1.25 mm)

CE; CU; CUL

125 °C (257 °F)

L50S020.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

20 A

End Cap

48 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

2 in (50.8 mm)

CE; CSA; UL

125 °C (257 °F)

Very Fast

051412.5MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

12.5 A

Pin Wire

114 J

-55 °C (-67 °F)

5 kA

2 m

Bulk

0.275 in (6.985 mm)

3AB

1.288 in (32.72 mm)

125 °C (257 °F)

Fast

0FLQ01.6HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.6 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLQ.300T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

300 mA

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

FLQ.600T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

600 mA

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

FLQ3

Littelfuse

Electric Fuse

Inline/Holder

500 V

3 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Slow

7945894975

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

25 A

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

097706.3MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

6.3 A

End Cap

188 J

-55 °C (-67 °F)

100 A

Rated Breaking Capacity at 450 VDC: 200 A, Pre-Arcing Time: Open within 10 ms at 1000% Rated Current

188

Bulk

0.205 in (5.2 mm)

500 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; PSE; SEMKO

125 °C (257 °F)

Time Lag

LA50P12004

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

1.2 kA

200 kA

LA50P

Rated Breaking Capacity at 450 VDC: 20000 A

CSA; UL

Fast

L50S450

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

2 in (50.8 mm)

2 x 2.22 in (50.8 x 56.4 mm)

2.22 in (56.4 mm)

CE; CSA; UL

Very Fast

FLQ01.6R

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.6 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

L50S250

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

250 A

Tab/Blade

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 2.094 in (38.1 x 53.2 mm)

2.094 in (53.2 mm)

CE; CSA; UL

Very Fast

CY10X38G.5

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 mA

End Cap

120 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Fast

NH00M35

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

35 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH00M10

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

10 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

2311315000

Littelfuse

Electric Fuse

Inline/Holder

500 V

3.15 A

End Cap

750 mJ

-25 °C (-13 °F)

1 kA

Bulk

0.248 in (6.3 mm)

1 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.126 in (3.2 mm)

70 °C (158 °F)

Very Fast

CY10X38M10

Littelfuse

Electric Fuse

Inline/Holder

500 V

10 A

End Cap

120 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Time Lag

CY14X51G32

Littelfuse

Electric Fuse

Inline/Holder

500 V

32 A

End Cap

120 kA

0.551 in (14 mm)

500 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Fast

NH00CG4

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

4 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

FLQ006

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

6 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

7945894952

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

200 mA

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

NH2CG200

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

200 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.402 in (61 mm)

1.575 in (40 mm)

Indicator

2.402 x 1.575 x 2.835 in (61 x 40 x 72 mm)

2.835 in (72 mm)

VDE

7945894981

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.125 A

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

FLQ002.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.