500 V Fuses 931

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

2312160002

Littelfuse

Electric Fuse

Inline/Holder

500 V

16 A

End Cap

68 J

-25 °C (-13 °F)

Nickel

1 kA

Bulk

0.248 in (6.3 mm)

500 V

1 ms

3AB

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

70 °C (158 °F)

Very Fast

KLH175

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

175 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

1.22 in (31 mm)

1.22 x 2.126 in (31 x 54 mm)

2.126 in (54 mm)

CSA; UL

Fast

NH00M32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

KLH90

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

90 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

1 in (25.4 mm)

1 x 2.126 in (25.4 x 54 mm)

2.126 in (54 mm)

CSA; UL

Fast

FLQ6.25

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

6.25 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LA050URD32TTI1800

Littelfuse

Electric Fuse

Inline/Holder

500 V

1.8 kA

End Cap

1.05 kJ

200 kA

LA

Indicator

UL

Very Fast

KLH550

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

550 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

2 in (50.8 mm)

2 x 2.22 in (50.8 x 56.4 mm)

2.22 in (56.4 mm)

CSA; UL

Fast

FLQ001.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

7945894955

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

400 mA

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

L50S800

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

800 A

Tab/Blade

Silver

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

2.5 in (63.5 mm)

e4

2.5 x 2.22 in (63.5 x 56.4 mm)

2.22 in (56.4 mm)

CSA; UL

Fast

FLQ.100

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

100 mA

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

NH0G16

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

16 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

DZ27F16

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

16 A

End Cap

80 kA

DZ

Rated Breaking Capacity at 500 VDC: 80000 A

0.846 in (21.5 mm)

Indicator

0.846 x 1.969 in (21.5 x 50 mm)

1.969 in (50 mm)

DIN; IEC; VDE

Fast

FLQ05.6R

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

5.6 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

NH2G300

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

300 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.921 in (74.2 mm)

1.969 in (50 mm)

Indicator

2.921 x 1.969 x 2.835 in (74.2 x 50 x 72 mm)

2.835 in (72 mm)

VDE

FLQ006.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

6 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

051406.3MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

6.3 A

End Cap

13.5 J

-55 °C (-67 °F)

5 kA

2 m

Bulk

0.25 in (6.35 mm)

3AB

1.25 in (31.75 mm)

125 °C (257 °F)

Fast

NH0G125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

FLQ.400T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

400 mA

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

KLH800

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

800 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 2.22 in (63.5 x 56.4 mm)

2.22 in (56.4 mm)

CSA; UL

Fast

FLQ32/10

Littelfuse

Electric Fuse

Inline/Holder

500 V

3.2 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Slow

0FLQ1.12T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.12 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLQ014R

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

14 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLQ.600R

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

600 mA

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

09773.15MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

3.15 A

End Cap

58 J

-55 °C (-67 °F)

Nickel

100 A

Rated Breaking Capacity at 450 VDC: 200 A, Pre-Arcing Time: Open within 10 ms at 1000% Rated Current

58

Bulk

0.205 in (5.2 mm)

500 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; PSE; SEMKO

125 °C (257 °F)

Time Lag

FLQ004.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

4 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

FLQ002

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLQ010.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

10 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

FLQ20

Littelfuse

Electric Fuse

Inline/Holder

500 V

20 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Slow

0FLQ.400HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

400 mA

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

592025S

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

25 A

End Cap

Silver

592

e4

NH3CG315

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

315 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.921 in (74.2 mm)

1.969 in (50 mm)

Indicator

2.921 x 1.969 x 2.835 in (74.2 x 50 x 72 mm)

2.835 in (72 mm)

VDE

CY10X38M8

Littelfuse

Electric Fuse

Inline/Holder

500 V

8 A

End Cap

120 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Time Lag

F60C500V3A

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

3 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 500 VDC: 150000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

MIL-PRF-15160/60

DZ27F2

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

2 A

End Cap

80 kA

DZ

Rated Breaking Capacity at 500 VDC: 80000 A

0.846 in (21.5 mm)

Indicator

0.846 x 1.969 in (21.5 x 50 mm)

1.969 in (50 mm)

DIN; IEC; VDE

Fast

L50QS175.V

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

175 A

Tab/Blade

3.148 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1.218 in (30.94 mm)

10 ms

2.125 in (53.98 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

L50S030

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

30 A

End Cap

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

0.563 in (14.3 mm)

2 in (50.8 mm)

CE; CSA; UL

Very Fast

FLQ9

Littelfuse

Electric Fuse

Inline/Holder

500 V

9 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Slow

NH1M125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.559 in (65 mm)

1.575 in (40 mm)

Indicator

2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm)

2.835 in (72 mm)

VDE

DZ33T50

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

50 A

End Cap

80 kA

DZ

Rated Breaking Capacity at 500 VDC: 80000 A

1.063 in (27 mm)

Indicator

1.063 x 1.969 in (27 x 50 mm)

1.969 in (50 mm)

DIN; IEC; VDE

Time Lag

LA50QS600-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

600 A

Tab/Blade

220 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

2 in (50.8 mm)

500 V

2 x 2.22 in (50.8 x 56.4 mm)

2.22 in (56.4 mm)

CSA; UL

Fast

FLQ005

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

5 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

23114000029

Littelfuse

Electric Fuse

Inline/Holder

500 V

4 A

End Cap

1.6 J

-25 °C (-13 °F)

Nickel

1 kA

Bulk

0.248 in (6.3 mm)

1 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

70 °C (158 °F)

Very Fast

DZ27T6

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

6 A

End Cap

80 kA

DZ

Rated Breaking Capacity at 500 VDC: 80000 A

0.846 in (21.5 mm)

Indicator

0.846 x 1.969 in (21.5 x 50 mm)

1.969 in (50 mm)

DIN; IEC; VDE

Time Lag

LA50QS200-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

200 A

Tab/Blade

20 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

1.22 in (31 mm)

500 V

1.22 x 2.13 in (31 x 54.1 mm)

2.13 in (54.1 mm)

CSA; UL

Fast

0505025.MX52LEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

500 V

25 A

Pin Wire

210 J

-55 °C (-67 °F)

Tin

30 kA

10 s

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.275 in (6.985 mm)

e3

500 V

3AB

1.288 in (32.72 mm)

125 °C (257 °F)

Fast

L50QS090.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

90 A

Tab/Blade

720 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1 in (25.4 mm)

10 ms

2.125 in (53.98 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

0505015.MX52LEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

500 V

15 A

Pin Wire

68 J

-55 °C (-67 °F)

Tin

50 kA

10 s

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.275 in (6.985 mm)

e3

500 V

3AB

1.288 in (32.72 mm)

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.