Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
20 A |
End Cap |
120 kA |
C14 |
0.551 in (14 mm) |
Indicator |
0.551 x 2.008 in (14 x 51 mm) |
2.008 in (51 mm) |
IEC |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
80 A |
End Cap |
120 kA |
C22 |
0.866 in (22 mm) |
Indicator |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
IEC |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
30 A |
End Cap |
200 kA |
Rated Breaking Capacity at 500 VDC: 150000 A |
0.406 in (10.31 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
MIL-PRF-15160/60 |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
2.25 A |
End Cap |
Nickel |
10 kA |
Bulk |
0.41 in (10.41 mm) |
CC |
500 V |
Midget |
0.41 x 1.5 in (10.41 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
500 mA |
End Cap |
50 mJ |
50 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.252 in (6.4 mm) |
0.252 x 1.252 in (6.4 x 31.8 mm) |
1.252 in (31.8 mm) |
CE; CSA; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
7 A |
End Cap |
50 J |
50 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.252 in (6.4 mm) |
0.252 x 1.252 in (6.4 x 31.8 mm) |
1.252 in (31.8 mm) |
CE; CSA; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
175 A |
Tab/Blade |
1.45 kJ |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
1.156 in (29.36 mm) |
1.156 x 1.836 in (29.36 x 46.63 mm) |
1.836 in (46.63 mm) |
CE; CSA; UL |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
6 A |
End Cap |
Bulk |
0.866 in (22 mm) |
Dll |
1.969 in (50 mm) |
CE; EAC |
|||||||||||||||||||
Legrand |
Electric Fuse |
Inline/Holder |
500 V |
100 A |
Tab/Blade |
120 kA |
Bulk |
2.362 in (60 mm) |
1.181 in (30 mm) |
NH00 |
Indicator |
2.126 in (54 mm) |
EN; IEC; VDE |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
20 A |
End Cap |
140 J |
-55 °C (-67 °F) |
Nickel |
30 kA |
10 s |
Rated Breaking Capacity at 500 VDC: 20000 A |
140 |
Bulk |
0.25 in (6.35 mm) |
500 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
500 V |
500 V |
30 A |
Pin Wire |
280 J |
-55 °C (-67 °F) |
Matte Tin |
30 kA |
10 s |
Rated Breaking Capacity at 500 VDC: 20000 A |
280 |
Bulk |
0.275 in (6.985 mm) |
e3 |
500 V |
3AB |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
125 °C (257 °F) |
Fast |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
500 V |
8 A |
Pin Wire |
28.8 J |
-55 °C (-67 °F) |
5 kA |
2 m |
Bulk |
0.275 in (6.985 mm) |
3AB |
1.288 in (32.72 mm) |
125 °C (257 °F) |
Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
40 A |
Tab/Blade |
1.09 kJ |
-55 °C (-67 °F) |
10 kA |
2 m |
Tray |
0.293 in (7.45 mm) |
0.236 x 1.26 in (6 x 32 mm) |
1.352 in (34.35 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
20 A |
End Cap |
120 J |
-55 °C (-67 °F) |
Silver |
30 kA |
10 s |
Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current |
Bulk |
0.252 in (6.4 mm) |
e4 |
500 V |
0.236 x 1.26 in (6 x 32 mm) |
1.252 in (31.8 mm) |
CUL; UL |
105 °C (221 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
1 A |
End Cap |
Nickel |
10 kA |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
500 mA |
End Cap |
350 mJ |
Nickel |
1.5 kA |
Bulk |
0.25 in (6.35 mm) |
500 V |
10 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
1.252 in (31.8 mm) |
UL |
Time Lag |
|||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
10 A |
End Cap |
620 J |
Nickel |
1.5 kA |
Bulk |
0.25 in (6.35 mm) |
500 V |
20 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.252 in (6.35 x 31.8 mm) |
1.252 in (31.8 mm) |
UL |
Time Lag |
||||||||||||
Siba |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
2.5 A |
End Cap |
19 J |
1.5 kA |
Bulk |
0.25 in (6.35 mm) |
500 V |
20 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
1.252 in (31.8 mm) |
UL |
Time Lag |
|||||||||||||||
Siba |
Electric Fuse |
Inline/Holder |
500 V |
6 A |
Tab/Blade |
36 J |
120 kA |
Bulk |
1.85 in (47 mm) |
1.161 in (29.5 mm) |
4 ms |
Indicator |
1.89 in (48 mm) |
IEC, VDE |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
10 A |
End Cap |
500 J |
-25 °C (-13 °F) |
Nickel |
1.5 kA |
Bulk |
0.248 in (6.3 mm) |
10 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
1.26 in (32 mm) |
CUL; UL |
85 °C (185 °F) |
Time Lag |
|||||||||||||
Altech |
Electric Fuse |
Inline/Holder |
500 V |
400 A |
Tab/Blade |
Bulk |
2.559 in (65 mm) |
2.087 in (53 mm) |
2.362 in (60 mm) |
Slow |
|||||||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
500 V |
12.5 A |
End Cap |
26 J |
-40 °C (-40 °F) |
Tin/Tin Copper |
10 kA |
Bulk |
0.25 in (6.35 mm) |
e3/e2 |
3600 s |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.252 in (6.35 x 31.8 mm) |
1.252 in (31.8 mm) |
UL |
85 °C (185 °F) |
Super Fast |
|||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
16 A |
End Cap |
760 J |
-40 °C (-40 °F) |
1.5 kA |
760 |
Box |
0.25 in (6.35 mm) |
20 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.252 in (6.35 x 31.8 mm) |
1.252 in (31.8 mm) |
CUL, UL |
85 °C (185 °F) |
Very Fast |
|||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
16 A |
End Cap |
760 J |
-40 °C (-40 °F) |
1.5 kA |
760 |
Bulk |
0.25 in (6.35 mm) |
20 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.252 in (6.35 x 31.8 mm) |
1.252 in (31.8 mm) |
CUL, UL |
85 °C (185 °F) |
Very Fast |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
10 A |
End Cap |
120 kA |
0.394 in (10 mm) |
500 V |
5AG |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
IEC |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
125 mA |
End Cap |
Nickel |
0.406 in (10.3 mm) |
500 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; MIL-F-15160/60; UL |
Fast |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
6 A |
End Cap |
Nickel |
200 kA |
Rated Breaking Capacity at 500 VDC: 150000 A |
0.406 in (10.31 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
MIL-PRF-15160/60 |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
1.5 A |
End Cap |
10 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
500 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
14 A |
End Cap |
10 kA |
Bulk |
0.41 in (10.41 mm) |
CC |
500 V |
Midget |
0.41 x 1.5 in (10.41 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
250 mA |
End Cap |
Nickel |
10 kA |
FNQ |
Box |
0.406 in (10.3 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
2.5 A |
End Cap |
Nickel |
10 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
500 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
200 mA |
End Cap |
Nickel |
10 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
500 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
20 A |
End Cap |
10 kA |
Box |
0.406 in (10.3 mm) |
500 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
8 A |
End Cap |
Nickel |
10 kA |
Bulk |
0.41 in (10.41 mm) |
CC |
500 V |
Midget |
0.41 x 1.5 in (10.41 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
|||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
500 V |
250 V |
2 A |
End Cap |
120 kA |
Rated Breaking Capacity at 250 VDC: 100000 A |
0.563 in (14.3 mm) |
500 V |
0.563 x 2.008 in (14.3 x 51 mm) |
2.008 in (51 mm) |
CE; IEC60269-1; IEC60269-2 |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
100 A |
Tab/Blade |
475 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.947 in (24.05 mm) |
0.947 x 1.736 in (24.05 x 44.09 mm) |
1.736 in (44.09 mm) |
CE; CSA; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
800 A |
Tab/Blade |
76.2 kJ |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
2.5 in (63.5 mm) |
2.5 x 2.09 in (63.5 x 53.09 mm) |
2.09 in (53.09 mm) |
CE; CSA; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
1 A |
End Cap |
1.8 J |
-55 °C (-67 °F) |
Nickel |
100 A |
10 ms |
Rated Breaking Capacity at 400 VDC: 1500 A |
1.8 |
Bulk |
0.205 in (5.2 mm) |
500 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
PSE; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
3.15 A |
End Cap |
50.109 J |
-55 °C (-67 °F) |
Nickel |
100 A |
10 ms |
Rated Breaking Capacity at 400 VDC: 1500 A |
50.1 |
Bulk |
0.205 in (5.2 mm) |
500 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
PSE; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
16 A |
End Cap |
68 J |
-55 °C (-67 °F) |
Nickel |
50 kA |
10 s |
Rated Breaking Capacity at 500 VDC: 20000 A |
68 |
Bulk |
0.25 in (6.35 mm) |
500 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CUL; TUV; UL |
125 °C (257 °F) |
Fast |
||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
500 V |
4 A |
End Cap |
8.4 J |
-40 °C (-40 °F) |
Tin/Tin Copper |
150 kA |
Bulk |
0.25 in (6.35 mm) |
e3/e2 |
3600 s |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.252 in (6.35 x 31.8 mm) |
1.252 in (31.8 mm) |
UL |
85 °C (185 °F) |
Super Fast |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
40 A |
End Cap |
120 kA |
C14 |
0.551 in (14 mm) |
0.551 x 2.008 in (14 x 51 mm) |
2.008 in (51 mm) |
IEC |
||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
500 V |
250 V |
4 A |
End Cap |
120 kA |
Rated Breaking Capacity at 250 VDC: 100000 A |
0.402 in (10.2 mm) |
1.496 in (38 mm) |
CE |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
2 A |
End Cap |
9.12 J |
-55 °C (-67 °F) |
Nickel |
100 A |
10 ms |
Rated Breaking Capacity at 400 VDC: 1500 A |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
PSE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
500 V |
500 V |
25 A |
Pin Wire |
210 J |
-55 °C (-67 °F) |
Matte Tin |
30 kA |
10 s |
Rated Breaking Capacity at 500 VDC: 20000 A |
210 |
Bulk |
0.275 in (6.985 mm) |
e3 |
500 V |
3AB |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
125 °C (257 °F) |
Fast |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
8 A |
End Cap |
203.52 J |
-55 °C (-67 °F) |
Nickel |
100 A |
10 ms |
Rated Breaking Capacity at 400 VDC: 500 A |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
125 A |
Tab/Blade |
1.503 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Bulk |
1.218 in (30.94 mm) |
10 ms |
2.125 in (53.98 mm) |
CE; CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
4 A |
End Cap |
52.48 J |
-55 °C (-67 °F) |
Nickel |
100 A |
10 ms |
Rated Breaking Capacity at 400 VDC: 500 A |
52.48 |
Bulk |
0.205 in (5.2 mm) |
500 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
PSE |
125 °C (257 °F) |
Time Lag |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.