500 V Fuses 931

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

FNQ-15/100

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

150 mA

End Cap

Nickel

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

0FLQ03.2HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

3.2 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

8020.5073.PT

Schurter Ag

Electric Fuse

Through Hole Mount

500 V

400 V

3.15 A

Pin Wire

8.6 J

-40 °C (-40 °F)

1.5 kA

Bulk

0.27 in (6.85 mm)

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.291 in (32.8 mm)

CUL, UL

85 °C (185 °F)

Very Fast

FNQ-1/10

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

100 mA

End Cap

Nickel

10 kA

Bulk

0.406 in (10.3 mm)

CC

500 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

0FLQ015.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

15 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0FLQ01.5T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.5 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

L50QS350.V

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

350 A

Tab/Blade

14.246 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1.5 in (38.1 mm)

500 V

10 ms

2.093 in (53.16 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

0FLQ030.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

30 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

63D33R

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

63 A

End Cap

26.5 kJ

50 kA

Bulk

1.063 in (27 mm)

DIII

1.969 in (50 mm)

DIN 49515; IEC60269

Ultra Fast

FLQ01.5

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.5 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLQ015

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

15 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0977012.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

450 V

12 A

Pin Wire

388 J

-55 °C (-67 °F)

Tin

100 A

Rated Breaking Capacity at 450 VDC: 200 A

388

Bulk

0.228 in (5.8 mm)

e3

500 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.886 in (22.5 mm)

CE; PSE

125 °C (257 °F)

Time Lag

A50QS400-4

Mersen S A

Electric Fuse

Inline/Holder

500 V

500 V

400 A

Tab/Blade

16 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A, Joule Integral Nom at 500 VDC: 83

1.5 in (38.1 mm)

1.5 x 2.091 in (38.1 x 53.1 mm)

2.091 in (53.1 mm)

CSA; UL

LA50QS400-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

400 A

Tab/Blade

98 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

1.5 in (38.1 mm)

500 V

1.5 x 2.091 in (38.1 x 53.1 mm)

2.091 in (53.1 mm)

CSA; UL

Fast

0477012.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

400 V

12 A

Pin Wire

576 J

-55 °C (-67 °F)

Matte Tin

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 500 A

Bulk

0.217 in (5.5 mm)

e3

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.846 in (21.5 mm)

CUL; PSE; TUV; UL

125 °C (257 °F)

Time Lag

09773.15MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

450 V

3.15 A

Pin Wire

58 J

-55 °C (-67 °F)

Matte Tin

100 A

Rated Breaking Capacity at 450 VDC: 200 A

58

Bulk

0.228 in (5.8 mm)

e3

500 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.886 in (22.5 mm)

CE; PSE; SEMKO

125 °C (257 °F)

Time Lag

8020.5073

Schurter Ag

Electric Fuse

Inline/Holder

500 V

400 V

3.15 A

End Cap

8.6 J

-40 °C (-40 °F)

1.5 kA

8.6

Bulk

0.25 in (6.35 mm)

8 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL, UL

85 °C (185 °F)

Very Fast

ATQ1/4

Mersen S A

Electric Fuse

Inline/Holder

500 V

250 mA

End Cap

10 kA

0.394 in (10 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ14

Mersen S A

Electric Fuse

Inline/Holder

500 V

14 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

0477005.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

400 V

5 A

End Cap

76.5 J

-55 °C (-67 °F)

Nickel

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 500 A

76.5

Bulk

0.205 in (5.2 mm)

500 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

PSE

125 °C (257 °F)

Time Lag

0477016.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

400 V

16 A

Pin Wire

1.331 kJ

-55 °C (-67 °F)

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 400 A

Bulk

0.217 in (5.5 mm)

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.846 in (21.5 mm)

CUL; PSE; UL

125 °C (257 °F)

Time Lag

0ADEC9120-BE

Bel Fuse

Electric Fuse

Inline/Holder

500 V

500 V

12 A

End Cap

140 J

-55 °C (-67 °F)

Silver

30 kA

10 s

Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current

Bulk

0.252 in (6.4 mm)

e4

500 V

0.236 x 1.26 in (6 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

105 °C (221 °F)

Fast

FWH-001A6F

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

1 A

End Cap

2 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.4

Box

0.248 in (6.3 mm)

500 V

0.248 x 1.26 in (6.3 x 32 mm)

0.252 x 1.252 in (6.4 x 31.8 mm)

1.26 in (32 mm)

CE; CSA; UL

Fast

1250NHG4G

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

1.25 kA

Tab/Blade

7 MJ

120 kA

Box

3.543 in (90 mm)

3.425 in (87 mm)

NH4

Indicator

4.016 in (102 mm)

CE; DIN; IEC; VDE

189140.5

Siba

Electric Fuse

Inline/Holder

500 V

400 V

5 A

End Cap

80 J

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Time Lag

189140.8

Siba

Electric Fuse

Inline/Holder

500 V

400 V

8 A

End Cap

370 J

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Time Lag

7022.0700

Schurter Ag

Electric Fuse

Inline/Holder

500 V

10 A

End Cap

30 J

-40 °C (-40 °F)

Tin/Tin Copper

10 kA

Bulk

0.25 in (6.35 mm)

e3/e2

3600 s

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

UL

85 °C (185 °F)

Super Fast

ATQ15

Mersen S A

Electric Fuse

Inline/Holder

500 V

15 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ8/10

Mersen S A

Electric Fuse

Inline/Holder

500 V

800 mA

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

C22G80S

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

80 A

End Cap

120 kA

C22

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

C22M80

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

80 A

End Cap

120 kA

C22

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

FNQ-30

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

30 A

End Cap

10 kA

Box

0.406 in (10.3 mm)

500 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

L50QS060.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

60 A

Tab/Blade

269 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1 in (25.4 mm)

10 ms

2.125 in (53.98 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

0477001.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

400 V

1 A

Pin Wire

1.8 J

-55 °C (-67 °F)

Tin

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 1500 A

Bulk

0.217 in (5.5 mm)

e3

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.846 in (21.5 mm)

PSE; VDE

125 °C (257 °F)

Time Lag

0477010.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

400 V

10 A

End Cap

509 J

-55 °C (-67 °F)

Nickel

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 500 A

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; PSE; TUV; UL

125 °C (257 °F)

Time Lag

0505016.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

500 V

16 A

Pin Wire

68 J

-55 °C (-67 °F)

Matte Tin

50 kA

10 s

Rated Breaking Capacity at 500 VDC: 20000 A

68

Bulk

0.275 in (6.985 mm)

e3

500 V

3AB

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE; CUL; TUV; UL

125 °C (257 °F)

Fast

0514005.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

5 A

Pin Wire

6.14 J

-55 °C (-67 °F)

5 kA

2 m

Bulk

0.275 in (6.985 mm)

3AB

1.288 in (32.72 mm)

125 °C (257 °F)

Fast

0ADEC9100-BE

Bel Fuse

Electric Fuse

Inline/Holder

500 V

500 V

10 A

End Cap

100 J

-55 °C (-67 °F)

Silver

30 kA

10 s

Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current

Bulk

0.252 in (6.4 mm)

e4

500 V

0.236 x 1.26 in (6 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

105 °C (221 °F)

Fast

0FLQ003.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

3 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0FLQ006.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

6 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

189140.3,15

Siba

Electric Fuse

Inline/Holder

500 V

400 V

3.15 A

End Cap

37 J

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Time Lag

ATQ1

Mersen S A

Electric Fuse

Inline/Holder

500 V

1 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ1/10

Mersen S A

Electric Fuse

Inline/Holder

500 V

100 mA

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ1/2

Mersen S A

Electric Fuse

Inline/Holder

500 V

500 mA

End Cap

10 kA

0.394 in (10 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ1/8

Mersen S A

Electric Fuse

Inline/Holder

500 V

125 mA

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ12

Mersen S A

Electric Fuse

Inline/Holder

500 V

12 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ8

Mersen S A

Electric Fuse

Inline/Holder

500 V

8 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

C10G2

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

2 A

End Cap

120 kA

C10

0.394 in (10 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.