Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.126 in (28.6 mm) |
J |
600 V |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
1.126 in (28.6 mm) |
J |
600 V |
Indicator |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
Silver |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.126 in (28.6 mm) |
e4 |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
31.1 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
31.1 kJ |
-40 °C (-40 °F) |
Silver |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
e4 |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Box |
1.339 in (34 mm) |
RK5 |
600 V |
1.339 x 7.874 in (34 x 200 mm) |
7.874 in (200 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
48 V |
100 A |
Tab/Blade |
Rated Breaking Capacity at 48 VDC: 1000 A |
1.15 in (29.2 mm) |
0.606 in (15.4 mm) |
1.15 x 0.606 x 0.354 in (29.2 x 15.4 x 9 mm) |
0.354 in (9 mm) |
UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
1 KV |
100 A |
Tab/Blade |
1.56 kJ |
-40 °C (-40 °F) |
Tin |
50 kA |
Bulk |
2.913 in (74 mm) |
0.866 in (22 mm) |
e3 |
0.984 in (25 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
400 V |
100 A |
Tab/Blade |
200 kA |
1.063 in (27 mm) |
4.606 in (117 mm) |
CSA; IEC; UL |
Time Delay |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
100 A |
Tab/Blade |
18.1 kJ |
120 kA |
Box |
1.929 in (49 mm) |
0.827 in (21 mm) |
NH000 |
Indicator |
1.614 in (41 mm) |
CE; DIN; IEC; VDE |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.142 x 2.638 in (29 x 67 mm) |
4.606 in (117 mm) |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
125 V |
72 V |
100 A |
Wraparound |
5 kJ |
-55 °C (-67 °F) |
500 A |
Tape And Reel, 13 inch |
0.484 in (12.3 mm) |
0.177 in (4.5 mm) |
125 V |
290 mΩ |
10 s |
0.177 in (4.5 mm) |
CUL |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
100 A |
Tab/Blade |
905 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Bulk |
1 in (25.4 mm) |
500 V |
10 ms |
2.125 in (53.98 mm) |
CE; CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
4 KV |
100 A |
Tab/Blade |
60 kA |
14.37 in (365 mm) |
2.244 in (57 mm) |
2.756 in (70 mm) |
||||||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
100 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
450 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 450 VDC: 100000 A |
1.13 in (28.7 mm) |
1.13 x 2.63 in (28.7 x 66.8 mm) |
2.63 in (66.8 mm) |
CSA; UL |
Fast |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
100 A |
Tab/Blade |
10 kA |
Rated Breaking Capacity at 125 VDC: 10000 A |
Box |
1.06 in (26.92 mm) |
H |
250 V |
1.06 x 5.88 in (26.92 x 149.35 mm) |
5.88 in (149.35 mm) |
CE; CSA; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
75 V |
100 A |
J Bend |
6.9 kJ |
-55 °C (-67 °F) |
Bright Tin Over Nickel |
1.5 kA |
1 m |
Pre Arcing Time: Open within 60 s at 200% Rated Current |
Tape And Reel |
0.441 in (11.2 mm) |
0.394 in (10 mm) |
e3 |
100 V |
0.441 x 0.394 x 0.236 in (11.2 x 10 x 6 mm) |
0.236 in (6 mm) |
CUL; UL |
100 °C (212 °F) |
||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
75 V |
100 A |
J Bend |
4.8 kJ |
-55 °C (-67 °F) |
1.5 kA |
1 m |
Tape And Reel |
0.441 in (11.2 mm) |
0.394 in (10 mm) |
75 V |
0.236 in (6 mm) |
CE; CUL; TUV; UL |
100 °C (212 °F) |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
31.1 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
ISO; UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
31.1 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
48 V |
100 A |
Tab/Blade |
2.5 kA |
3.181 in (80.8 mm) |
48 V |
3.18 in (80.77 mm) |
UL |
Very Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
200 kA |
FLSR |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.311 in (33.3 mm) |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
100 A |
Tab/Blade |
200 kA |
2.953 in (75 mm) |
2.953 x 1.642 in (75 x 41.7 mm) |
1.642 in (41.7 mm) |
CE; CSA; UL |
Very Fast |
|||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
500 V |
100 A |
End Cap |
2.065 kJ |
200 kA |
Bulk |
0.866 in (22 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
100 A |
Tab/Blade |
200 kA |
1.126 in (28.6 mm) |
J |
600 V |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 600 VDC: 100000 A |
1.339 in (34 mm) |
Indicator |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
100 A |
End Cap |
1.1 kJ |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
32 V |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.311 in (33.3 mm) |
Indicator |
1.311 x 7.874 in (33.3 x 200 mm) |
7.874 in (200 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.283 in (32.6 mm) |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.283 in (32.6 mm) |
Indicator |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.311 in (33.3 mm) |
Indicator |
1.311 x 7.874 in (33.3 x 200 mm) |
7.874 in (200 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
100 A |
Tab/Blade |
200 kA |
10 s |
Box |
1.06 in (26.924 mm) |
RK5 |
250 V |
1.06 x 5.88 in (26.92 x 149.35 mm) |
5.88 in (149.352 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
Legrand |
Electric Fuse |
Inline/Holder |
500 V |
100 A |
Tab/Blade |
120 kA |
Bulk |
2.362 in (60 mm) |
1.181 in (30 mm) |
NH00 |
Indicator |
2.126 in (54 mm) |
EN; IEC; VDE |
||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
Indicator |
2.795 in (71 mm) |
2.795 in (71 mm) |
UL |
Time Delay |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
100 A |
Tab/Blade |
200 kA |
10 s |
Pre Arcing Time: Open within 10 s at 500% Rated Current |
Bulk |
0.044 in (1.11 mm) |
0.31 in (7.88 mm) |
CE; CUL; UL |
Time Delay |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.