Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
100 A |
Tab/Blade |
437 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
1.929 in (49 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
100 A |
Tab/Blade |
974 J |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.823 in (71.7 mm) |
1.693 in (43 mm) |
Indicator |
1.929 in (49 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
100 A |
Tab/Blade |
437 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
1.929 in (49 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
1.031 in (26.2 mm) |
Indicator |
5.874 in (149.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
1.031 in (26.2 mm) |
5.874 in (149.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
100 A |
Tab/Blade |
2.67 kJ |
-40 °C (-40 °F) |
30 kA |
Bulk |
1 in (25.4 mm) |
2.875 in (73.03 mm) |
125 °C (257 °F) |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
100 A |
Tab/Blade |
Blister |
||||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
100 A |
Tab/Blade |
Blister |
||||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
100 A |
Tab/Blade |
10 kA |
1.063 in (27 mm) |
5.874 in (149.2 mm) |
CE; CSA; UL |
||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
100 A |
Tab/Blade |
-55 °C (-67 °F) |
200 kA |
Box |
1.063 in (27 mm) |
2.906 in (73.8 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
100 A |
Tab/Blade |
Bulk |
||||||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
100 A |
Tab/Blade |
50 kJ |
200 kA |
Rated Breaking Capacity at 250 VDC: 20000 A |
1.063 in (27 mm) |
Indicator |
5.874 in (149.2 mm) |
CE; CSA; UL |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
100 A |
Tab/Blade |
10 kA |
1.311 in (33.3 mm) |
7.874 in (200 mm) |
CE; CSA; UL |
||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
100 A |
Tab/Blade |
Blister |
||||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.311 in (33.3 mm) |
7.874 in (200 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
100 A |
Tab/Blade |
Bulk |
||||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.063 in (27 mm) |
5.874 in (149.2 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
100 A |
Tab/Blade |
Blister |
||||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.311 in (33.3 mm) |
Indicator |
7.874 in (200 mm) |
CE; CSA; UL; QPL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
100 A |
Tab/Blade |
Bulk |
||||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.063 in (27 mm) |
5.874 in (149.2 mm) |
CE; CSA; UL; QPL |
Time Delay |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
100 A |
Tab/Blade |
158 kJ |
200 kA |
Rated Breaking Capacity at 600 VDC: 20000 A |
1.311 in (33.3 mm) |
Indicator |
7.874 in (200 mm) |
CSA; UL |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
100 A |
Tab/Blade |
Blister |
||||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
100 A |
Tab/Blade |
Blister |
||||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
68.15 kJ |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.126 in (28.6 mm) |
Indicator |
2.626 in (66.7 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
100 A |
Tab/Blade |
-55 °C (-67 °F) |
200 kA |
Box |
1 in (25.4 mm) |
2.874 in (73 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
100 A |
Tab/Blade |
966 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
1 in (25.4 mm) |
2.875 in (73.03 mm) |
CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
100 A |
Tab/Blade |
437 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
100 A |
Tab/Blade |
974 J |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.823 in (71.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
100 A |
Tab/Blade |
437 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
100 A |
Tab/Blade |
10 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.008 in (51 mm) |
GPV |
1.5 KV |
NH |
2.008 in (51 mm) |
UL |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
100 V |
100 A |
Tab/Blade |
100 kA |
L13S |
Rated Breaking Capacity at 100 VDC: 20000 A |
1 in (25.4 mm) |
1 x 1.157 in (25.4 x 29.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
100 A |
End Cap |
80 kA |
5 m |
3 in (76.2 mm) |
Striker |
3 x 10.875 in (76.2 x 276.23 mm) |
10.874 in (276.2 mm) |
Medium |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
100 V |
100 A |
Tab/Blade |
100 kA |
KLW |
Rated Breaking Capacity at 100 VDC: 20000 A |
1 in (25.4 mm) |
1 x 1.157 in (25.4 x 29.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
100 A |
Tab/Blade |
200 kA |
1 in (25.4 mm) |
J |
600 V |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; QPL; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
750 V |
100 A |
Tab/Blade |
18 J |
100 kA |
Rated Breaking Capacity at 750 VDC: 100000 A |
1.22 in (31 mm) |
Indicator |
1.22 x 6.811 in (31 x 173 mm) |
6.811 in (173 mm) |
UL |
Very Fast |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
100 A |
End Cap |
80 kA |
5NLE-100E |
3 in (76.2 mm) |
3 x 17.874 in (76.2 x 454 mm) |
17.874 in (454 mm) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
100 A |
End Cap |
80 kA |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
100 A |
Tab/Blade |
50 kJ |
50 kA |
1.063 in (27 mm) |
1.063 x 3.874 in (27 x 98.4 mm) |
5.874 in (149.2 mm) |
CE; CSA; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
End Cap |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
100 A |
Tab/Blade |
437 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
1.929 in (49 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
100 kA |
Bulk |
1 in (25.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
100 A |
Tab/Blade |
437 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
1.929 in (49 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
Silver |
Rated Breaking Capacity at 170 VDC: 100000 |
0.563 in (14.3 mm) |
e4 |
0.563 x 1.26 in (14.3 x 32.004 mm) |
1.26 in (32.004 mm) |
UL |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.